KEMKRAFT KEI-850 Скачать руководство пользователя страница 2

KEMKRAFT

 

ENGINEERING, INC.

 

MODEL KEI-850 READOUT BOX 

 

96-033.doc  

 

 

2

 

47650 Clipper Dr. Plymouth Twp., MICHIGAN  48170  (734)-414-6500 

 

 

*

 

INSTALLATION

 

INSTRUCTIONS

 

*

 

 

1.  The KEI-850 Display box should be permanently installed in a location that is best for the 

application.  It is usually mounted straight out the drivers side window on a pedestal stand. 

 

2.  When the box is installed, place a vehicle in the alignment machine and install the 

mechanical fixture onto the steering wheel.  Ensure that the KEI-850 display box can be 

easily viewed while loading an Unfixtured Clear Vision Tool onto a steering wheel.

 

 

 

* OPERATING

 

INSTRUCTIONS

 

*

 

 

NOTE: As always, these Steering Wheel Gauges are delicate, accurate, gauging tools 

that need to be treated as such and therefore must be installed in a holder when 

not in use.  If these tools do not have a holder & are thrown down on a table 

during use, the warranty will be void. 

 

1.  Apply power to the KEI-850 by turning on the power switch located on the bottom left part 

of the enclosure.  This power switch also doubles as a circuit breaker for the KEI-850 

Display box.  Should the breaker ever trip the power switch only needs to be turned to the 

off position and back on to reset the breaker. 

 

2.  After the power has been applied to the KEI-850 Display box the LCD display will have this 

display. 

 

 

 

 

 

4.  If power is applied and the KEI-850 Display box has the LCD has the following display, the 

calibration data is bad and the unit needs to be calibrated. 

 

 

 

 

 

 

 

 

* WARRANTY AND SERVICE INSTRUCTIONS * 

 

Kemkraft Engineering, Inc. warranties this equipment against defects in workmanship and 

materials for a period of 90 days from date of shipment.  We will, at our option, repair or 

replace products which prove defective during the warranty period.  No other warranty, 

expressed or implied, is given.  KEI is not liable for consequential damages.  Damage caused 

to the equipment as a result of improper use or abuse, or unauthorized modification of the 

instrument is not covered under this warranty. 

 

For service contact: 

Kemkraft Engineering, Inc. 

734-414-6500 

 

 

47650 Clipper Dr. 

734-414-6599 fax 

 

 

   Plymouth 

Twp., 

Michigan 

48170

 

XX.XX Deg  TL#1

 

CAL  SW = Calibrate

 

MEMORY ERROR

 

CALIBRT TOOL NOW

 

Содержание KEI-850

Страница 1: ...FT ENGINEERING INC MODEL KEI 850 READOUT BOX 96 033 doc 1 47650 Clipper Dr Plymouth Twp MICHIGAN 48170 734 414 6500 INSTRUCTION MANUAL CLEAR VISION DUAL INCLINOMETER BOX MODEL KEI 850 REVISION DATE 26 MAR 98 ...

Страница 2: ... of the enclosure This power switch also doubles as a circuit breaker for the KEI 850 Display box Should the breaker ever trip the power switch only needs to be turned to the off position and back on to reset the breaker 2 After the power has been applied to the KEI 850 Display box the LCD display will have this display 4 If power is applied and the KEI 850 Display box has the LCD has the followin...

Страница 3: ...ad Press CAL switch again to calibrate If a calibration procedure is to be performed press the CAL switch a second time and the program will go into the cal procedure If the cal procedure is not desired a countdown timer will countdown for 15 seconds and the program will go back to the RUN MODE The red LED should turn off and the green LED should turn back on D If calibration is desired press the ...

Страница 4: ...sion Tool is used the limit switch on the tool closes and dumps the angle of the tool out of the serial port in Hexadecimal SERIAL PORT PROTOCOL N 8 1 4800 BAUD DUMP STRING 02 x x x 03 xx 02 start of text xx most significant byte xx middle xx least 03 end of text xx check sum BURKE E PORTER FORI INTERFACE The connector is set up for three wire RS 232 interface ground transmit and receive The inter...