can be used. Set the transducers to the angle and enter the 5 digits of the angle (60.000) on
the keyboard or select * if the displayed angle is correct to continue.
20. When the last angle is entered, the display will read "Calibration Complete".
21. Calibrate all transducers and check the angle values using the System Setup menu XDCR
Angles display.
To calibrate the Pedal Force Transducer:
1. Connect the KEI-095 brake tester to a 12.6 to 15 volt, 500 ma power supply. Connect all
transducers to their brake tester ports.
2. Turn on the brake tester. Press any key to display the main menu.
3. Press the 1 key to enter the Calibration mode.
4. To prevent unwanted access to the calibration modes a numeric code must be entered.
Enter "1", "2", "3", "4" on the keypad. The calibration menu will be displayed.
5. Press the 2 key to calibrate the pedal force transducer.
6. The display will show the current raw transducer output. For the pedal force transducer, just
place on a level surface. Press the 0 key.
7. Place a known weight from 22.2 to 440.4 N on the transducer and enter the five numbers of
the weight on the keypad. Be sure to enter any leading zeros and the decimal point will be
entered automatically.
8. When the fourth number is entered, the calibration is complete. Press the * key to exit the
calibration mode.
To calibrate the Brake Pressure Transducer:
1. Connect the KEI-095 brake tester to a 12.6 to 15 volt, 500 ma power supply. Connect all
transducers to their brake tester ports.
2. Connect the pressure transducer through the KE095CB with the cable and transducer.
3. Turn on the brake tester. Press any key to display the main menu.
4. Press the 1 key to enter the Calibration mode.