23
Specifications
Version: FAU_M_EN_170308_E004
Terminals
5.2.
FAU 50
NOTE:
If the inverse input (terminal 8) is not used, connect terminal 7 and 8.
Terminal
No.
Function, Electrical Specification
1
+ analogue output
}
} 0/4–20 mA or 0/2–10 V
2
– analogue output
3
collector
}
forward/backward out U
max
30 V DC,
I
max
50 mA low-inductive
4
emitter
5
+12 V DC supply voltage for KEM-Pickups or -Amplifiers, max. 20 mA
6
frequency input CH1, NAMUR or voltage level
7
0 V potential reference for external supply and control inuputs HOLD and RESET
8
frequency input CH2, NAMUR or voltage level
9
(+) supply voltage FAU
}
24 V DC, 115 V AC oder
10
(–) supply voltage FAU
230 V AC / 4 VA, (± 15 %)
11
RESET, low-active control input (connect with terminal 7, 0 V)
12
HOLD, low-active control input (connect with terminal 7, 0 V)
13
collector pulse output
}
U
max
30 V DC, Imax 50 mA low-inductive
14
emitter
15
collector limit MAX output
}
U
max
30 V DC, Imax 50 mA low-inductive
16
emitter
17
collector limit MIN output
}
U
max
30 V DC, Imax 50 mA low-inductive
18
emitter
19
collector 1:1 frequency
}
U
max
30 V DC, Imax 50 mA low-inductive
20
emitter