Kelvinator KWH20CMB Скачать руководство пользователя страница 5

Kelvinator Air Conditioning

  installation  9

8  specifications/installation  

Kelvinator Air Conditioning

Fig. 3

Step 2 Remove the frame.

1  Remove the two fixed screws from the frame. (see Fig.3)
2   Grasp the left corner in the frame's underside, then 

loosen the frame. (see Fig.4)

Step 3 Installation

1   Remove the screws fix the chassis-fixing board and 

cabinet. some Models have two more screws on the back 
of the cabinet. (see Fig.5)

2   Grasp the handle on the chassis and carefully slide the 

air conditioner out of the cabinet. (see Fig.6)

3   When you need to drain off the water, install the drain 

plug on the Chassis board. Then fix the cabinet on the 
support, (provided by the installer unless you elect to 
install yourself) (see Fig.7).

4  Push the unit chassis into the cabinet. (see Fig.8)
5  Fix the chassis and cabinet. (see Fig.5)

Step 4 Install frame

1  Install the frame. (see Fig.9)
2  Fix the screws on the frame. (see Fig.3)
1   Install the air filter into the frame's slot from upside to 

underside. (see Fig.2)

2   Hang the front panel on the frame's buckle, then press 

the front panel into the frame's slot until hear a click. 
(see Fig.10)

Appliance Amps

Size (mm)

A

400

B

500

C

210

D

60

The Treatment of Condensed Water

To meet different requirements of different types of air 
conditioner, there are two kinds of methods for your choice 
to treat the condensed water. You can choose back drainage 
or bottom-drainage.
See the following procedure to perform back drainage:
1   Fit the seal onto the drain joint (provided with your air 

conditioner accessory).

2  Remove the rubber plug from the back of the unit.
3   Attach the drain joint to the back of the cabinet where 

you remove the plug and rotate 90

O

 to securely 

assemble them.

4   Connect the drain joint with a extension drain hose 

(Locally purchased)

SEAL

DRAIN 

JOINT

RUBBER 

PLUG

RUBBER 

PLUG

SCREW

DRAIN PAN

DRAIN 

OUTLET

Installation Steps
Step 1 Remove the front panel and the air filter

1   Hold the slot under the front panel, then uplift it 

outwards, and remove the front panel (See Fig.1).

2   Pinch the handle under the air filter and make the air filter 

arched, remove it from the slot from underside to upside 
(See Fig.2).

Select The Best Location
Install the unit at a place having sufficient strength to support 
the unit securely.
For maximum efficiency, install the air conditioner on a 
side of a house or building which favors more shade than 
direct sunlight.
Provide sufficient clearance or space around the air inlet and 
air outlet so that air flow will not be obstructed. The following 
figures give detailed requirements.
Only trained and qualified service personnel should install, 
repair or service air conditioning equipment. Users should 
not install the air conditioner by themselves.

5-

10

m

m

Make rear side lower so that water
will drain out smoothly.

Less than C

more than D

Wall thickness is less than C

O

45

Scrape

If the wall thickness is more than
scrape the wall as shown above.

C

More
thanA

More than B

Less than C

More
thanA

Installation

Specifications

Unit dimensions:

Model (Btu/h)

Body dimension (mm) 

(WxHxD)

< 2.6 kw (9000Btu/h)

452x342x550

Suggest minimum wire size (AWG:American Wire Gage):

Appliance Amps

AWG Wire Size

10

18

Содержание KWH20CMB

Страница 1: ...Window Wall Manual Room Air Conditioner User Manual KWH15CMB KWH20CMB Refrigerant R410A ...

Страница 2: ...ocal recycling depot or by placing them in appropriate collection containers If you wish to discard this air conditioner please contact your local authorities and ask for the correct method of disposal caution The air conditioner is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditi...

Страница 3: ... cord 6 Do not start stop operation by plugging unplugging the power cord Usage 1 Exposure to direct airflow to occupants pets or plants for an extended period of time could be hazardous to your health 2 Due to the possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices Cleaning and maintenance 1 Do not touch the metal parts of the unit when remo...

Страница 4: ...nt to discharge stale air CLOSE VENT OPEN CLOSE OPEN To open the vent pull the lever towards you To close it push it in CLOSE VENT OPEN CLOSE OPEN To open the vent set the lever to the right position To close it set the lever in the left position Note When turning the SELECTOR knob from LOW COOL to HIGH COOL keep your speed slow as far as possible Do not change the operation mode between LOW COOL ...

Страница 5: ...nt provided with your air conditioner accessory 2 Remove the rubber plug from the back of the unit 3 Attach the drain joint to the back of the cabinet where you remove the plug and rotate 90O to securely assemble them 4 Connect the drain joint with a extension drain hose Locally purchased SEAL DRAIN JOINT RUBBER PLUG RUBBER PLUG SCREW DRAIN PAN DRAIN OUTLET Installation Steps Step 1 Remove the fro...

Страница 6: ...where the Appliance is used in a multi family communal or share type environment the Appliance will then be warranted against manufacturing defects in Australia for 3 months following the date of original purchase of the Appliance h you means the purchaser of the Appliance not having purchased the Appliance for re sale and your has a corresponding meaning 2 This warranty only applies to Appliances...

Страница 7: ...rmation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Отзывы: