
Kelvinator Air Conditioning
installation 9
8 specifications/installation
Kelvinator Air Conditioning
Fig. 3
Step 2 Remove the frame.
1 Remove the two fixed screws from the frame. (see Fig.3)
2 Grasp the left corner in the frame's underside, then
loosen the frame. (see Fig.4)
Step 3 Installation
1 Remove the screws fix the chassis-fixing board and
cabinet. some Models have two more screws on the back
of the cabinet. (see Fig.5)
2 Grasp the handle on the chassis and carefully slide the
air conditioner out of the cabinet. (see Fig.6)
3 When you need to drain off the water, install the drain
plug on the Chassis board. Then fix the cabinet on the
support, (provided by the installer unless you elect to
install yourself) (see Fig.7).
4 Push the unit chassis into the cabinet. (see Fig.8)
5 Fix the chassis and cabinet. (see Fig.5)
Step 4 Install frame
1 Install the frame. (see Fig.9)
2 Fix the screws on the frame. (see Fig.3)
1 Install the air filter into the frame's slot from upside to
underside. (see Fig.2)
2 Hang the front panel on the frame's buckle, then press
the front panel into the frame's slot until hear a click.
(see Fig.10)
Appliance Amps
Size (mm)
A
400
B
500
C
210
D
60
The Treatment of Condensed Water
To meet different requirements of different types of air
conditioner, there are two kinds of methods for your choice
to treat the condensed water. You can choose back drainage
or bottom-drainage.
See the following procedure to perform back drainage:
1 Fit the seal onto the drain joint (provided with your air
conditioner accessory).
2 Remove the rubber plug from the back of the unit.
3 Attach the drain joint to the back of the cabinet where
you remove the plug and rotate 90
O
to securely
assemble them.
4 Connect the drain joint with a extension drain hose
(Locally purchased)
SEAL
DRAIN
JOINT
RUBBER
PLUG
RUBBER
PLUG
SCREW
DRAIN PAN
DRAIN
OUTLET
Installation Steps
Step 1 Remove the front panel and the air filter
1 Hold the slot under the front panel, then uplift it
outwards, and remove the front panel (See Fig.1).
2 Pinch the handle under the air filter and make the air filter
arched, remove it from the slot from underside to upside
(See Fig.2).
Select The Best Location
Install the unit at a place having sufficient strength to support
the unit securely.
For maximum efficiency, install the air conditioner on a
side of a house or building which favors more shade than
direct sunlight.
Provide sufficient clearance or space around the air inlet and
air outlet so that air flow will not be obstructed. The following
figures give detailed requirements.
Only trained and qualified service personnel should install,
repair or service air conditioning equipment. Users should
not install the air conditioner by themselves.
5-
10
m
m
Make rear side lower so that water
will drain out smoothly.
Less than C
more than D
Wall thickness is less than C
O
45
Scrape
If the wall thickness is more than
scrape the wall as shown above.
C
More
thanA
More than B
Less than C
More
thanA
Installation
Specifications
Unit dimensions:
Model (Btu/h)
Body dimension (mm)
(WxHxD)
< 2.6 kw (9000Btu/h)
452x342x550
Suggest minimum wire size (AWG:American Wire Gage):
Appliance Amps
AWG Wire Size
10
18