Kelvinator KWH16CMF Скачать руководство пользователя страница 7

Kelvinator Air Conditioning 

 air conditioning features/care and cleaning  7

caution

Clean your air conditioner occasionally to keep it looking 
new. Be sure to unplug the unit before cleaning to prevent 
shock or fire hazards.

Air 

fi

lter cleaning

The air filter should be checked at least once a month to  
see if cleaning is necessary. Trapped particles in the filter 
can build up and cause an accumulation of frost on the 
cooling coils.

   Hold the slot under the front panel, then uplift it 

onwards, and remove the front panel.

   

arched, remove it from the underside to upside.

   

warm water. Rinse filter thoroughly.

   

filter is thoroughly dry before replacing. Or, instead of 
washing you may vacuum the filter clean.

Note:  Never use hot water over 40

o

C(104 F) to clean the air 

filter. Never attempt to operate the unit without the  
air filter.

Cabinet Cleaning

   Be sure to unplug the air conditioner to prevent shock 

or fire hazard. The cabinet and front may be dusted with 
an oil-free cloth or washed with a cloth dampened in 
a solution of warm water and mild liquid dishwashing 
detergent. Rinse thoroughly and wipe dry.

   Never use harsh cleaners, wax or polish on the 

cabinet front.

   Be sure to wring excess water from the cloth before 

wiping around the controls.

   Excess water in or around the controls may cause 

damage to the air conditioner.

  Plug in air conditioner.

NOTE:  Never use water over 50

o

C, alcohol, gasoline, acid, 

solvent or brush to clean the front panel as this will 
damage the surface of the part.

Winter Storage

If you plan to store the air conditioner during the winter, 
remove it carefully from the window according to the 
installation instructions. Cover it with plastic or return it to 
the original carton.

Care and cleaning

Vent control

The vent control is located above the control knobs. 

 

For maximum cooling efficiency, CLOSE the vent. 
This will allow internal air circulation.
OPEN the vent to discharge stale air.

 

 

   

E        VENT     

  OPEN

CLOSE          OPEN

close

open

 

To open the vent, push the lever to the right.
To close it, push the lever to the left.

Содержание KWH16CMF

Страница 1: ...Window Wall Manual Room Air Conditioner User Manual KWH16CMF Refrigerant R32 ...

Страница 2: ...echanic with knowledge of appropriate gas reclamation methods Do not use means to accelerate defrosting or to clean other than those recommended by the manufacturer The appliance shall not be stored in a room with continuously operating ignition sources Do not pierce or burn caution The air conditioner is not intended for use by young children or infirm persons without supervision Young children s...

Страница 3: ...stibles such as gasoline benzene thinner etc It may cause an explosion or fire Ventilate room before operating air conditioner if there is a gas leakage from another appliance It may cause explosion fire and burns Do not disassemble or modify unit It may cause failure and electric shock Safety precautions Kelvinator Air Conditioning important safety instructions 3 caution Contact an authorised ser...

Страница 4: ...m well when used together with a stove etc An oxygen shortage may occur Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use for special purposes Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Stop operation and close the window in storm or ...

Страница 5: ...the power outlet used for this product has suitable current rating should be provided with reliable earth wire power cord A E N Fig 1 Fig 2 wall outlet air break switch E earthwire yellow green N neutral wire blue A active wire brown The operation panel of your unit will look like the following NOTE The outline of the operation panel is based on typical model the function is the same with your air...

Страница 6: ...or the units with AIR SWING feature automatic When the AIR SWING switch is turned to ON position the vertical louvres automatically oscillate right and left sweeping the cold air around to obtain comfortable cooling The vertical louvres may be stopped at any position when the AIR SWING switch is turned OFF AUTO SWING OFF ON On some models To adjust horizontal ai ow direction move the lever gently ...

Страница 7: ... The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air condit...

Страница 8: ...use it will prevent heat radiation of the condensor Restriction of outside air will greatly reduce the cooling and heating e ciency of the air conditioner 4 5 Install the unit with its bottom portion 75 150cm above th oor level t n e d n e p e d n i n a o t d e t c e n n o c e b t s u m d r o c r e w o p e h T 6 circuit The yellow green wire must be grounded 7 Based on calculations in compliance w...

Страница 9: ...d water 1 Take out the drain pan and screws provided within your air conditioner accessories bag 2 Install the drain pan at the bottom of the unit and secure it with the screws provided 3 Connect a suitable sized drain hose not supplied to the drain outlet located on the underside of the drain pan Drain plug Cooling only models The drain plug is fitted from the factory to capture condensed water t...

Страница 10: ...FAN setting Sound of fan hitting water moisture removal system This is normal when humidity is high Close doors windows and registers Window vibration poor installation Refer to installation instructions or check with installer Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions che...

Страница 11: ...Kelvinator Air Conditioning warranty 11 ...

Страница 12: ... information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 13 13 49 email customercare electrolux com au web kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au 66129933408 ...

Отзывы: