  Cleaning the air filters  17

General maintenance

If the air conditioner is not going to be used for a long period 
of time:
•  Operate in fAN only mode for 3~4 hours to allow the 

unit to completely dry out.

•  Switch off the unit and pull out the power plug.
•  Remove the batteries from the remote control.
•  The outdoor unit requires periodic maintenance and 

cleaning. Do not attempt to do this yourself. Contact 
your dealer or service technician.

Checks before operation

•  Check that the wiring is not broken or disconnected
•  Check that the dust filter is installed.
•  Check if the air outlet or inlet is blocked if the air 

conditioner has not been used for a long time.

warning

Do not touch the metal parts of the unit when removing the 
filter. Injuries can occur when handling sharp metal edges.
Do not use water to clean inside the air conditioner. 
Exposure to water can destroy the insulation, leading to 
possible electric shock.
When cleaning the unit, first make sure that the power and 
circuit breaker are turned off. 

4   The healthy air freshening filters (if applicable) like Active 

carbon filter / BIO filter / Vitamin C filter / Silver ion filter 
are fixed on the dust filter.

 

Remove the healthy air filters from the support frame of 
the dust filter.

 

Clean the healthy air filters at least every three (3) months 
and replace every 6 months.

 

Clean with vacuum cleaner if possible.

5   Install the healthy air filters back in position.

6   Install the upper portion of the dust filters back into the 

unit, taking care that the left and right edges line up 
correctly and place dust filters into position.

dust filter

plasma filter

Содержание KSV26CRE

Страница 1: ...Inverter Split System Room Air Conditioner User Manual KSV26CRE KSV26HRE KSV35CRE KSV35HRE KSV53HRE KSV62HRE KSV70CRE KSV70HRE KSV80HRE Refrigerant R32 ...

Страница 2: ...ioner please contact your local authorities and ask for the correct method of disposal refrigerant warning This unit uses refrigerant R32 and must be disposed of by a licensed refrigeration mechanic with knowledge of appropriate gas reclamation methods caution The air conditioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ...

Страница 3: ...e is a gas leakage from another appliance It may cause explosion fire and burns Do not disassemble or modify unit It may cause failure and electric shock Safety instructions Kelvinator Air Conditioning Important safety instructions 3 Contact an authorised installer for installation of this unit Contact an authorised service technician for repair or maintenance of this unit The socket outlet requir...

Страница 4: ...n electric shock Ventilate the room well when used together with a stove etc An oxygen shortage may occur Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use for special purposes Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Stop operation...

Страница 5: ...ol button 8 Remote control 9 Remote control holder 10 Refrigerant pipe if applicable 11 Drain hose if applicable 12 Power cable if applicable 13 Mounting plate 14 Connecting cable if applicable NOTE All the pictures in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail 1 2 3 4 5 6 7 8 10 9 14 13 11 12 Air inlet Air inlet rear ...

Страница 6: ...h waste separately for special treatment is necessary tips and information When changing batteries use only new and matching batteries otherwise it may cause problems with the remote control If the remote control is not used for a long time remove the batteries as old batteries may leak or corrode and damage the remote control The battery life during normal use is about six months If the remote co...

Страница 7: ...L Buttons Press the button to increase the temperature setting Press the button to decrease the temperature setting In Timer On Off or Clock functions use these buttons to adjust the timer or set the clock 12 CLOCK Button Press this button and the Clock symbol will blink You can press Control buttons and to set the time you want 13 TEMP Temperature Button Press this button to change the remote con...

Страница 8: ...r 14 MODE Display Displays the current operation mode including Auto Dehumidify Fan Cool and Heat NOTE The Cool model does not offer a Heating option 1 2 3 4 5 6 7 8 14 9 10 11 12 13 1 Transmission Indicator Displays when the remote control transmits signals to the indoor unit 2 Turbo Display Displays when Turbo function is active 3 I feel Display Displays when the I feel function is active 4 Eco ...

Страница 9: ...for reverse cycle models or fan only operation depending on which temperature you have selected and the ambient room temperature Once you have selected the operating mode the operating conditions are saved into the unit s memory Thereafter the air conditioner will start operating under the same conditions when you simply push the ON OFF button on the remote control Start Ensure the unit is plugged...

Страница 10: ...rks based on the difference between the set temperature and the actual room temperature The temperature is regulated while dehumidifying through repeatedly turning on off of the COOLING operation on or off or by turning the FAN only operation on or off fan cooling fan cooling programmed temperature time Start Ensure the unit is plugged in and power is available The OPERATION indicator on the displ...

Страница 11: ...set the Clock Press the Clock button and the clock display will start to flash Follow step 1 and 2 to set the new time tips and information The clock timer uses a 24 hour clock mode The default time for remote control is 12 00PM and it will revert to this when the batteries are changed Start Ensure the unit is plugged in and power is available The OPERATION indicator on the display panel of the in...

Страница 12: ...te control Timer On Operation 1 Press the TIMER ON button will flash on the display of the remote control the very first time the Timer ON operation is used With all subsequent uses the last set time will flash 2 Set the desired time by pressing the Control buttons Forward Backward Each time you press the buttons the time will move forward or backward by 1 minute Holding the button down will scrol...

Страница 13: ... The air conditioner will quit I Feel operation if no temperature information is received from the remote control for eleven 11 successive minutes 6 Confirm the set time by pointing the remote control at the indoor unit and pressing the Timer On button again symbol will stay on the remote control display and the function is activated Timer Off Timer On On Stop Start operation This function is reco...

Страница 14: ... conditioner with horizontal louvre in closed position When the air conditioner is connected to power initial operation the horizontal louvre may generate a sound for 10 seconds this is a normal part of the operation Additional options 1 Smart restart function The air conditioner automatically resumes the previous settings after a power failure 2 Removable panel The front panel of indoor unit can ...

Страница 15: ...r On and Timer Off buttons on the remote control to select the desired time for start up and shut down Do not place any object close to the air inlets or outlets as it reduces the efficiency of the unit and may cause damage to the air conditioner Clean the air filters frequently otherwise cooling or heating performance may be reduced When the remote control is lost or fails to operate please use t...

Страница 16: ...on piping Clean and check for obstructions Each season before start up Indoor outdoor coils Clean Each season before start up This operation must be performed by qualified personnel only warning Stop the air conditioner and disconnect the power supply before cleaning Indoor unit and remote control cleaning Use a dry cloth to wipe the indoor unit and remote control A cloth dampened with cold water ...

Страница 17: ... parts of the unit when removing the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and circuit breaker are turned off 4 The healthy air freshening filters if applicable like Active carbon filter BIO fi...

Страница 18: ...he X Fan function is switched off Operating tips The following events may occur during normal operation 1 Protection of the air conditioner Compressor protection The compressor will not restart for 3 minutes after it stops Anti freezing If the unit is operating in COOL mode in a low ambient temperature frost may be formed on the heat exchanger When the indoor heat exchanger temperature decreases b...

Страница 19: ...age is too high or too low Have a Certified Electrician test the voltage Batteries in remote control may have been exhausted Replace the batteries The time you have set with timer is incorrect Wait or cancel timer setting The unit does not cool or heat if applicable the room very well while air flows out from the air conditioner Inappropriate temperature setting Set the temperature correctly For d...

Страница 20: ...ter dirty Is the door or window open Is low fan speed set Are there heat sources in the room Water leakage of indoor unit The humidity is high Condensing water overflows Drain hose is loose or obstructed Water leakage of outdoor unit During cooling operation water condenses around the pipes and connection joints During defrosting operation thawed water flows out During heating operation water on t...

Страница 21: ...Kelvinator Air Conditioning Notes 21 Notes ...

Страница 22: ...22 Notes Kelvinator Air Conditioning Notes ...

Страница 23: ...nless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi inco...

Страница 24: ...about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Отзывы: