![Kelvinator KSV25CRH Скачать руководство пользователя страница 14](http://html2.mh-extra.com/html/kelvinator/ksv25crh/ksv25crh_installation-manual_4008777014.webp)
14 Outdoor unit installation
Kelvinator Air Conditioning
Electrical connection
Wiring diagram
1(L)
1(L)
2(N)
2(N)
S
S
L
N
Indoor unit terminal block
(3)
Power supply
Outdoor unit terminal block
Key:
1(L) = Live (Brown)
2(N) = Neutral (Blue)
S = Signal (White)
= Earth (Yellow & Green)
Installation of DRED network cable
The following models are equipped with a RJ45 Demand Response
connection socket to facilitate demand response control by your
electricity provider:
Please refer to your electricity provider for more information about
DRED.
The DRED socket is located inside the outdoor unit near the
terminal block, and is labelled "DR", refer to
re 19.
Connect the demand response cable into the DRED socket labelled
DR, ensure that a click is heard to con
t has locked into place.
Secure the demand response cable in the cable clamp, then the
terminal block cover and secure with screws.
Outdoor unit installation
Magnetic ring installation
S
2(N)
L
N
1(L)
Y/G
4cm
4cm
Magnetic ring
Magnetic ring
INDOOR UNIT
POWER SUPPLY
S
2(N)
L
N
1(L)
Y/G
INDOOR UNIT
POWER SUPPLY
Please note that different models are supplied with a different
combination of magnetic rings that must be installed by a
licensed electrician. These magnetic rings (if required) help to
minimise electro magnetic interference, which if not installed
correctly may impact television and radio operation.
The installer must install the magnetic rings inside the outdoor
unit electrical cover by clipping around the wires (as explained
below) located approximately 4cm from the terminal block and
securing in place with a cable ties.
Fig. 19a
Fig. 19b
DR
DR
KSD25HRH, KSD35HRH, KSD50HRH, KSD71HRH, KSD90HRH,
KSD25HWH, KSD35HWH, KSD50HWH, KSD71HWH, KSD90HWH
Models KSV50HRH, KSD50HRH, KSV50HWH & KSD50HWH are
supplied with two magnetic rings that must be clipped around
both the power supply in wires (L, N & Earth) and the
interconnecting wires (1(L), 2(N), S & Earth) leading to the
indoor unit.
Models KSV25CRH, KSV25HRH, KSD25HRH, KSV25HWH,
KSD25HWH, KSV35CRH, KSV35HRH, KSD35HRH,
KSV35HWH, KSD35HWH, KSV71CRH, KSV71HRH,
KSD71HRH, KSV71HWH, KSD71HWH, KSV90HRH,
KSD90HRH, KSV90HWH & KSD90HWH do not require
magnetic rings to be fitted.