Kelvinator KSE88CRC Скачать руководство пользователя страница 2

2  Contents  

Kelvinator Air Conditioning

Speed Split room air conditioner. We are sure you will find  
your new air conditioner a pleasure to use. Before you use 
the air conditioner, we recommend that you read through  
the entire user manual, which provides the description of  
the air conditioner and its functions.
To avoid the risks that are always present when you use an 
electrical appliance, it is important that the air conditioner  
is installed correctly and that you read the safety instructions 
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet  
for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not 
damaged. If in doubt, do not use the air conditioner but  
contact your local Electrolux Customer Care Centre.

environmental tip 

Information on disposal for users

•    Most of the packing materials are recyclable.  

Please dispose of those materials through your local 
recycling depot or by placing them in appropriate 
collection containers.

•    If you wish to discard this air conditioner, please contact 

your local authorities and ask for the correct method  
of disposal.

caution

•    The air conditioner is not intended for use by young 

children or infirmed persons without supervision.

•    Young children should be supervised to ensure that 

they do not play with the air conditioner. 

•    Contact an authorised installer for installation of this unit.
•    Contact an authorised service technician for repair or 

maintenance of this unit.

•    If the power cord is to be replaced, replacement work  

shall be performed by authorised personnel only.

•    Installation work must be performed in accordance  

with the national wiring Standards by authorised 
personnel only.

Conditions of use

similar applications such as:

•    

Staff kitchen areas in shops, offices and other working 
environments

•  

Farm houses

•    

By clients in hotels, motels, and other residential 
type environments

•  

Bed and breakfast type environments

Contents  ............................................................................ 2

Safety precautions ............................................................ 3

Notice for installation ....................................................... 3

Installation drawing .......................................................... 5

Installation of indoor unit ................................................. 6

Refrigerant pipe connection  ............................................. 8 

Installation of outdoor unit ............................................... 9

Check after installation and operation test .................... 10

Installation and Maintenance of HEPA Filter .................. 10

Congratulations

Contents

11

Warranty ..........................................................................

This appliance is intended to be used in household and 

Congratulations and thank you for choosing our Fixed 

Содержание KSE88CRC

Страница 1: ...Installation Manual Refrigerant R410A KSE26CRC KSE26HRC KSE35CRC KSE35HRC KSE53HRC KSE62HRC KSE88HRC KSE70CRC KSE70HRC KSE88CRC Fixed Speed Split Room Air Conditioner...

Страница 2: ...contact your local authorities and ask for the correct method of disposal caution The air conditioner is not intended for use by young children or infirmed persons without supervision Young children...

Страница 3: ...f the following If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard warning Before obtaining access to ter...

Страница 4: ...aminated with industrial vapours and oils the air contains sulphurous gas such as in hot spring zones corrosion or poor air quality exists Installation Site of Indoor Unit 1 The air inlet and outlet s...

Страница 5: ...e not adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided space necessary for properinstallation of the unit include the mini...

Страница 6: ...ard slightly without distortion bulge or fluctuation Do not put the outlet in the water Installation of indoor unit Installation of Mounting Plate 1 The mounting plate should be installed horizontally...

Страница 7: ...should be 2m or more above the floor Right Fig 2 Fig 1 Tailing 1 Tailing 2 Finally wrap it with tape Gas side piping insulation Water drainage pipe Liquid side Piping insulation Gas side pipe Externa...

Страница 8: ...igerant leakage is due to defects in the flaring work Carry out correct flaring work using the following procedure Oblique 90 C Roughness Burr A Cut the pipes and the cable 1 Use the piping kit access...

Страница 9: ...Then tighten the nut 5 Keep vacuuming for more than 15mins and make sure the reading of multi meter is 1 0 105 pa 76cmHg 6 Fully open high low pressure valves 7 Remove charging hose from charging end...

Страница 10: ...acity is not accurate Operation Test 1 Before Operation Test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off va...

Страница 11: ...anty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exha...

Страница 12: ...r email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux fami...

Отзывы: