This User Manual has been prepared for owners and users  
of the hot water system. Please keep it in a safe place for 
future reference. 

warning

Installation must be performed by a qualified installer (for 
example, a licensed plumber or gas fitter).

 

caution

•    Contact an authorised service technician for repair or 

maintenance of this hot water system.

•    If any power cord or cable is damaged and needs to 

be replaced, replacement work must be performed by 
authorised personnel only.

•    Installation work must be performed in accordance  

with national standards by authorised personnel only. 
Wrong connection can cause over heating or fire.

•   This hot water system should be installed in accordance 

with AS/NZS 3000 and your electricity suppliers rules.

For the installer

The installation must be completed in accordance with the 
information supplied in the Installation Manual that comes 
with your solar hot water system.
All other relevant National, State or Local regulations must 
also be conformed with and these include (but are not 
limited to): 
•  Australian Standard AS3500.1 – Water Supply 
•  Australian Standard AS3500.4 – Hot Water Supply 
•  Australian Standard AS3000 – Electrical Installation 
•  Australian Gas Association Code AS5601 –  

 Gas Appliance Installation 

•  Local Water, Gas & Electrical Authority Regulations  

 Municipal Building Codes 

•  The solar hot and solar cold pipes between the hot water 

storage tank and solar collectors MUST BE copper and 
fully insulated with closed cell polymer insulation or 
similar (minimum thickness of 20mm). Thicker insulation  
may be required to comply with the requirements of  
AS/NZS 3500.4. 

•  The insulation must be weatherproof and UV resistant if 

exposed to sunlight. All compression fittings must use 
brass or copper olives.

•  Plastic pipe MUST NOT be used, as it will not withstand 

the temperature and pressure of the water generated 
by the solar collectors under stagnation conditions. 
The solar collector can generate extremely high water 
temperatures up to 272°C. Plastic pipe can not withstand 
these temperatures and MUST NOT be used. Failure of 
plastic pipe can lead to the release of high temperature 
water and cause severe water damage and flooding.

•  The minimum supply water pressure for correct operation 

is 150kPa. If the supply water pressure could exceed 
600kPa, a 600kPa pressure limiting valve must be installed.

•  If the solar hot water system is electric boosted, the 

heating element is designed to be connected to extended 
off peak and not standard off peak (also called off peak 1).

 

This symbol indicates never to do this

 

This symbol indicates always do this

warning

  

 

Connect with power supply properly.

Otherwise, it may cause electric shock or fire due to 
excess heat generation.

  

 

Always ensure effective earthing.

No earthing may cause electric shock.

  

 

Disconnect the power to the hot water system and 
turn off the gas inlet valve to the gas booster if smoke, 
strange sounds or smells are coming from the system. 

It may cause fire or electric shock.

 

Do not operate or stop the hot water system by 
switching on or off the power.

It may cause electric shock or fire due to heat generation.

Do not use a damaged or unspecified power cord.

It may cause electric shock or fire.
If a power cord is damaged, it must be replaced by 
the manufacturer or an authorised service centre or a 
similarly qualified person in order to avoid a hazard.

Do not modify power cord length or share the outlet 
with other appliances.

It may cause electric shock or fire due to heat generation.

Do not operate with wet hands or in damp environment.

It may cause electric shock.

Do not allow water to run into electric parts.

It may cause failure of machine or electric shock.

 

Do not use the socket if it is loose or damaged.

It may cause fire and electric shock.

 

Do not open the hot water system during operation.

It may cause electric shock.

 

Do not allow any power cords or cables to rest close  
to hot surfaces.

It may cause fire and electric shock.

Do not disassemble or modify the hot water system.

It may cause failure and electric shock.

 

Important

Kelvinator solar hot water systems  

important  3

Содержание KHWSGENU/1

Страница 1: ...Solar Hot Water Systems User Manual ...

Страница 2: ...it is not damaged If in doubt do not use the hot water system but contact your local Electrolux Customer Care Centre Meanings of symbols used in this manual are shown below warning This symbol indicates information concerning your personal safety caution This symbol indicates information on how to avoid damaging the hot water system environmental tips This symbol indicates tips and information abo...

Страница 3: ...high water temperatures up to 272 C Plastic pipe can not withstand these temperatures and MUST NOT be used Failure of plastic pipe can lead to the release of high temperature water and cause severe water damage and flooding The minimum supply water pressure for correct operation is 150kPa If the supply water pressure could exceed 600kPa a 600kPa pressure limiting valve must be installed If the sol...

Страница 4: ... be installed operated and maintained in accordance with the manufacturers instructions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Children should be sup...

Страница 5: ...s 26L Natural gas KGC26SNA flow water heater 26L LPG gas KGC26SLA Kelvinator solar hot water systems components 5 Your solar hot water system components please tick hot water storage tank solar evacuated tube collector solar flat panel collector solar controller gas continuous flow water heater When calling the service centre please refer to this section of the user manual as it will help in descr...

Страница 6: ...osted 340L tank 2 Evacuated tube collectors Off peak 2 KSE340E3A C Kelvinator Solar Electric boosted 340L tank 3 Evacuated tube collectors Continuous tariff KSE340E3A OP2 Kelvinator Solar Electric boosted 340L tank 3 Evacuated tube collectors Off peak 2 KSE450E3A C Kelvinator Solar Electric boosted 450L tank 3 Evacuated tube collectors Continuous tariff KSE450E3A OP2 Kelvinator Solar Electric boos...

Страница 7: ...nside the collector This water when hot enough is circulated using a pump inside a solar controller which is fixed to the storage tank located on the ground If there is solar gain the solar controller will circulate water from inside the storage tank through the collector s and back to the tank Depending on your system the storage tank capacity may be 270L 340L or 450L Your solar hot water system ...

Страница 8: ... ensure that all sediment is removed 9 De activate the relief valve returning it to its normal position 10 Reconnect the inlet piping to the storage tank and then turn on the isolation valve located on the inlet piping to allow mains water to refill the tank Cleaning the solar collectors Over time dust and debris may build up on the collectors reducing their efficiency It is recommended that you h...

Страница 9: ... the tap for a period of time and all air has been expelled from the system close the hot water tap 12 Clean all filters in the hot water system including any that may be located on individual fixtures as they may have become blocked by debris during the process of flushing and draining of the hot water system 13 Check that all isolation valves that are designed to be open during normal operation ...

Страница 10: ...e call a service technician Water is discharging from the relief valve drainage pipe It s normal for a small amount of water to discharge during heating to allow for hot water expansion However if the relief valve appears to be continually leaking water activate the relief valve lever once or twice and then check to see if the leak stops If the relief valve is still leaking this could indicate a p...

Страница 11: ...nsported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by...

Страница 12: ...her information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...