background image

2  contents  

Kelvinator gas continuous flow hot water systems

Congratulations and thank you for choosing our gas 
continuous flow hot water system. We are sure you will find  
your new hot water system a pleasure to use. Before you use 
your hot water system, we recommend that you read through 
the entire user manual, which provides the description of the 
hot water system and its functions.
To avoid the risks that are always present when you use  
an appliance, it is important that the hot water system  
is installed correctly and that you read the safety instructions 
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet  
for future reference and pass it on to any future owners.
After unpacking the hot water system please check it is not 
damaged. If in doubt, do not use the hot water system but  
contact your local Electrolux Customer Care Centre.

NOTE: The actual gas heating appliance that is part of this 
gas continuous flow hot water system will here after be 
refered to as "water heater" for the purposes of this manual. 
The gas continuous flow hot water system as a whole may 
also be refered to as "hot water system" for simplicity.

environmental tips

Information on disposal for users

•    Most of the packing materials are recyclable.  

Please dispose of those materials through your local 
recycling depot or by placing them in appropriate 
collection containers.

•    If you wish to discard this hot water system, please 

contact your local authorities and ask for the correct 
method of disposal.

  
•    Contact an authorised installer for installation of this hot 

water system.

•    Contact an authorised service technician for repair or 

maintenance of this hot water system.

•    If the power cord is to be replaced, replacement work  

must be performed by authorised personnel only.

•    Installation work must be performed in accordance  

with national standards by authorised personnel only. 
Wrong connection can cause over heating or fire.

•   This hot water system should be installed in accordance 

with AS/NZS 3000 and your electricity suppliers rules.

Conditions of use

This hot water system is intended to be used in household 
and similar applications such as :
•  staff kitchen areas in shops, offices and other working  
 environments.
•  farm houses.
•  by clients in hotels, motels and other residential type  
 environments.
•  bed and breakfast type environments.

Important .......................................................................... 3 
Important safety instructions ........................................... 4
Specifications .................................................................... 5
Your gas continuous flow hot water system  .................... 6
  How it works  .................................................................. 6
  Initial operation ............................................................... 7 
  Normal operation ............................................................ 8
Freeze prevention ............................................................. 9
  Winter shutdown ............................................................. 9
Maintenance and service ................................................ 10 
  Water heater draining and filter cleaning ..................... 10 
General troubleshooting ................................................. 11 
Warranty .......................................................................... 15 
  

Congratulations

Contents

Содержание KGC20BNA

Страница 1: ...Gas Continuous Flow Hot Water System User Manual ...

Страница 2: ... materials are recyclable Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers If you wish to discard this hot water system please contact your local authorities and ask for the correct method of disposal Contact an authorised installer for installation of this hot water system Contact an authorised service technician for repa...

Страница 3: ...u ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service This symbol indicates never to do this This symbol indicates always do this warning Connect with power properly Otherwise it may cause electric shock or fire due to excess heat generation Always ensure effective earthing No earthi...

Страница 4: ...sed in water Immediately call a qualified service technician to inspect the water heater and to replace any damaged parts If this water heater is a 70 C model installed as part of a gas boosted solar hot water system please refer to the user manual supplied with that system for safety regarding the relief valves installed to limit temperature pressure and energy Ensure the following safety instruc...

Страница 5: ...ing label position Serial number label position Gas type label position MODELS KGC20BNA KGC20KNA KGC20SNA KGC20BLA KGC20KLA KGC20SLA KGC26BNA KGC26KNA KGC26SNA KGC26BLA KGC26KLA KGC26SLA Capacity L min 20L min 26L min Gas Input MJ h 160 195 Inlet Supply Pressure kPa Nat Gas 1 13 min 1 13 min 2 75 max 2 75 max Inlet Supply Pressure kPa LPG 2 61 min 2 89max 2 61 min 2 89max Water Supply Pressure kPa...

Страница 6: ... only Open any hot tap or fixture in the house Open the cold water isolation valve located on the inlet to the water heater Once water is flowing freely from the open hot tap or fixture indicating that all air has been dispelled from the system close the open hot water tap or fixture Open the gas isolation valve located on the inlet to the water heater Plug in the power cord to the power outlet if...

Страница 7: ... water caution The following process should be completed by the installer only Once all checks have been completed please clean filter of any debris Refer to page 10 for instructions 1 Fully open the manual water control valve on the water supply line 2 Open a hot water tap to verify that water is flowing to that tap then turn the tap off 3 Fully open the manual gas control valve installed ...

Страница 8: ...r is off PRIORITY C BURNER ON ON OFF PRIORITY HOT COOL MADE IN JAPAN Main priority lamp priority button burner on lamp KGCMRCA ON OFF button burner on lamp display set temperature 40 NOTE If power to the hot water system is lost then re set the remote controller will also lose power and switch off If the water is still running during this time it will go cold until the remote controller is switche...

Страница 9: ...nd being damaged Follow these instructions carefully 1 Close the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve located on the water supply line 4 Open all hot water taps in the house Bathroom kitchen laundry room etc When the water flow has ceased close all hot water taps 5 Have a bucket or pan to catch the water from the water heater s...

Страница 10: ...ning and filter cleaning 1 Close the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve 4 Open all hot water taps in the house bathroom kitchen laundry room etc When the residual water flow has ceased close all hot water taps 5 Have a bucket or pan to catch the water from the water heater s drain plugs Unscrew the drain plugs to drain all th...

Страница 11: ...to keep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Fluctuation in hot water temperature Is the filter on the cold water inlet clean Is the gas line sized properly Is the supply gas pressure enough Are the cold water and hot water lines cross connected Water heater Problem Possible solutio...

Страница 12: ...12 notes Kelvinator gas continuous flow hot water systems Notes ...

Страница 13: ...Kelvinator gas continuous flow hot water systems notes 13 Notes ...

Страница 14: ...14 notes Kelvinator gas continuous flow hot water systems Notes ...

Страница 15: ... is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is dam...

Страница 16: ...her information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Отзывы: