14

 

a temporary over-current, momentarily high or low 

battery voltage. This can happen during normal 

operation. 

3,3 

¤¤¤    ¤¤¤ 

Hall throttle is open 
or short-circuit 

When the throttle is repaired, a restart will clear the 

fault. 

3,4 

¤¤¤    ¤¤¤¤  Non-zero throttle on 

direction change

 

Controller  won‟t  allow  a  direction change unless the 
throttle or speed is at zero. Fault clears when throttle 

is released. 

4,1 

¤¤¤¤    ¤ 

Regen or Start-up 
over-voltage 

Motor drive is disabled if an over-voltage is detected 

at  start-up  or  during  regen.  The  voltage  threshold 

detection  level  is  set  during  configuration.  The  max 

threshold  is  about  1.25  times  of  controller  rated 

voltage. I.e. you may set threshold lower than 60V for 

48V controller.

 

4, 3 

¤¤¤¤    ¤¤¤ 

Motor 
over-temperature 

Motor temperature has exceeded the configured 

maximum. The controller will shut down until the 

motor temperature cools down. 

The Red LED flashes once at power on as a confidence check and then normally stays 

Off. “1, 2” means the Red flashes once and after a second pause, flashes twice. The time 
between two flashes is 0.5 second. The pause time between multiple flash code groups is 
two seconds.

 

 

Contact Us: 

 

Kelly Controls,Inc 

 

Home Page: 

http://www.KellyController.com 

 

Download user manual,instructions and user program: 

www.kellycontroller.com/support.php

 

 
E-mail: 

[email protected] 

 

Phone:   

(01) 224 637 5092 
 

Содержание SPM4812S

Страница 1: ...Full Bridge 4Q Permanent Magnet Motor Controller User s Manual V1 1 Kelly SPM Mini Full Bridge 4Q Permanent Magnet Motor Controller User s Manual Devices Supported Rev1 1 Feb 2023 SPM4812S SPM7212S SP...

Страница 2: ...2 Features and Specifications 2 2 1 General functions 2 2 2 Features 3 2 3 Specifications 4 Chapter 3 Wiring and Installation 5 3 1 Mounting the Controller 5 3 2 Connections 7 3 3 Installation Check...

Страница 3: ...Extended fault detection and protection The LED flashing pattern indicates the fault sources 2 Monitoring battery voltage Stop driving if battery voltage is too high or too low 3 Built in current loo...

Страница 4: ...no arc no wearing no life limit easy maintenance 4 Voltage monitoring on voltage source 12V and 5V 5 Current limit and torque control Configurable torque mode and speed mode 6 Low EMC 7 LED fault cod...

Страница 5: ...throttle 7 Analog Brake and Throttle Input 0 5 Volts 8 Reverse Alarm Main Contactor Coil Driver Meter 9 Full Power Temperature Range 0 to 50 controller case temperature 10 Operating Temperature Range...

Страница 6: ...water and contaminants To ensure full rated output power the controller should be fastened to a clean flat metal surface with four screws Applying silicon grease or some other thermal conductive mate...

Страница 7: ...Kelly SPM Mini Full Bridge 4Q Permanent Magnet Motor Controller User s Manual V1 1 6 Figure 2 SPM 18S mounting holes dimensions dimensions in millimeters...

Страница 8: ...2V Source Red 9 Relay Main contactor driver Blue 7 PWR Controller power supply input Pink 10 Alarm To drive reverse beeper 200mA Yellow DJ7091Y 2 3 21 Pin Definition 15 Micro_SW Throttle switch input...

Страница 9: ...er until you are certain the controller wiring is correct and has been double checked Wiring faults will damage the controller Ensure that the B wiring is securely and properly connected before applyi...

Страница 10: ...ge 4Q Permanent Magnet Motor Controller User s Manual V1 1 9 3 2 2 Wiring of SPM Controller 3 2 2 1 Standard wiring of SPM controller Figure 4 SPM controller standard wiring Battery voltage can be use...

Страница 11: ...e pin is for Kelly current meter Figure 5 Wiring of current meter pin The 12V input signal of the pin supplies the second braking function of the controller Figure 6 wiring of BRK2 3 2 3 Communication...

Страница 12: ...or is still running let alone change the settings in the user program Make sure the wire is connected correctly Turn the PWR switch on The Green LED stay on steadily and Red LED turns off when the con...

Страница 13: ...e that the controller is dry before reconnecting the battery Make sure the connections to the bus bars if fitted are tight To avoid physically stressing the bus bars use two well insulated wrenches 4...

Страница 14: ...if battery volts returns to normal 2 Check battery volts recharge if required 1 4 Over temperature warning 1 Controller case temperature is above 90 Current will be limited Reduce controller loading o...

Страница 15: ...d detection level is set during configuration The max threshold is about 1 25 times of controller rated voltage I e you may set threshold lower than 60V for 48V controller 4 3 Motor over temperature M...

Отзывы: