
Kelly KLS-H Brushless Motor Controller User’s Manual
V 1.10
23
4.3 Step 3
(1)RLS_TPS Brk %: RLS TPS Braking Percent, the percent of Releasing Pedal BRK in max
braking. Range: 0~50
This is used to adjust the regen current of releasing throttle regen mode type.The regen will
happen as long as the throttle is released completely.
Factory set is 0
(2)NTL Brk %: NTL Braking Percent, the percent of Neutral Braking in max braking. Range:
0~50
Only useful when you enable Three gears switch in user program.
The regen will happen when you turn F-N-R switch from Forward or backward to Neutral
position.
Factory set is 0
(3)Accel Time: Accel Time, the time of TPS Torque from 0 to max, accuracy 0.1s, 5 is equal to
0.5s. Range: 1~250
Factory set is 10
(4)Accel Rls Time: Accel Release Time, the time of TPS Torque from max to 0, accuracy 0.1s.
Range: 1~250
Factory set is 1
(5)Brake Time: Brake Time, the time of Brake Torque from 0 to max, accuracy 0.1s. Range:
1~250
Factory set is 15
(6)Brake Rls Time: Brake Release Time, the time of Brake Torque from max to 0, accuracy 0.1s.
Range: 1~250
Factory set is 1
(7)BRK_SW Brk %: BRK_SW Braking Percent, the percent of BRK_SW in max braking. Range:
0~50
The brake switch regen mode.You have to turn on the brake switch after the throttle is released
for the regen to occur.
Factory set is 10
(8)Brake Analog regen Brk%:It is used to adjust the max regen percentage of brake variable
regen mode.
This regen mode doesn't need brake switch to support any more for KLS controller.
(8)Torque Speed KP: Speed Percent Kp in Torque Mode. Range: 0~10000
Factory set is 3000
Torque Speed KI: Speed Integral Ki in Torque Mode. Range: 0~500
Factory set is 80
Содержание KLS6022H
Страница 2: ...Kelly KLS H Brushless Motor Controller User s Manual V 1 10 Rev 1 10 Jun 2017 ...
Страница 3: ......