Kelly KLS8080I/IPS Sinusoidal Brushless Motor Controller User’s Manual
V 1.10
35
3,1
¤¤¤
¤
Reserved
3,2
¤¤¤
¤¤
Internal reset
May be caused by some transient fault condition like
a temporary over-current, momentarily high or low
battery voltage. This can happen during normal
operation.
3,3
¤¤¤
¤¤¤
Hall throttle is open
or short-circuit
When the throttle is repaired, a restart will clear the
fault.
3,4
¤¤¤
¤¤¤¤
Angle sensor error
1.Speed sensor type error
,
customers may set the
correct sensor type through user program or App.
Please download how to use Identification function
instruction from our website.
2.Incorrect wiring.
3.Speed sensor is damaged or defective.Or feedback
signal is erratic.
4,1
¤¤¤¤
¤
Reserved
4, 2
¤¤¤¤
¤¤
Reserved
4, 3
¤¤¤¤
¤¤¤
Motor
over-temperature
Motor temperature has exceeded the configured
maximum. The controller will shut down until the
motor temperature cools down.
4, 4
¤¤¤¤
¤¤¤¤
Hall Galvanometer
sensor error
1.Hall galvanometer device is damaged inside the
controller.
This error code is only valid for KLS-8080I/IPS
controller.
Customers may read error codes in PC software or Android Tablet
Contact Us:
Kelly Controls
Home Page:
http://www.KellyController.com
Download user manual,instructions and user program:
www.kellycontroller.com/support.php
E-mail:
Phone:
(01) 224 637 5092