Kelly Ebike Brushless DC Motor Controller User’s Manual
V 3.4
Page 9
11.
Hall phase C
12.
Hall phase B
13.
Hall phase A
14.
RTN: Signal return
Notes:
1. All RTN pins are internally connected. RTN is internally connected to B-.
2. Switch to ground is active. Open switch is inactive
Caution:
•
Do not apply power until you are certain the controller wiring is correct and has been
double checked. Wiring faults will damage the controller.
•
Ensure that the B- wiring is securely and properly connected before applying power.
•
The preferred connection of the system contactor or circuit breaker is in series with the B+
line.
•
All contactors or circuit breakers in the B+ line must have precharge resistors across their
contacts. Lack of even one of these precharge resistors may severely damage the
controller at switch-on.