Kelly KDHE High Efficient Series/PM Motor Controller User’s Manual
V 3.4
20
data[0]
Ia A/D
data[1]
Ib A/D
data[2]
Vb A/D
Description: Data batch reading.
1)
For Vb A/D value and voltage mapping relation is:
V = Vad / 1.39.
2)
Ia, Ib are defined as the drive and regen current.
Command
CCP_MONITOR1
Length
1
data[0]
0x33
Controller response
Length
6
data[0]
PWM
data[1]
enable motor rotation
data[2]
motor temperature
data[3]
Controller’s temperature
data[4]
temperature of high side FETMOS heat sink
data[5]
temperature of low side FETMOS heat sink
Description: Data batch reading.
1) PWM is output duty cycle, from 0 to 100.
2) data[1] indicates enabling motor rotation or disabling. 1 - enable, 0 - disable.
3) data[2] is defined as the temperature of motor in Celsius temperature. If the
temperature sensor is not connected, the controller returns 0xFF.
4) data[3]-data[5] are defined as controller inside temperature in Celsius temperature.
The value of data[4] and data[5] are inaccurate below 30
℃
.
Command
CCP_MONITOR2
Length
1
data[0]
0x37
Controller response
Length
3
data[0]
MSB of error code
data[1]
LSB of error code
data[2]
present current accounts for percent of the rated current of controller
Description: Data batch reading.
1
)
Controller error status
:
(data[0] << 8) | data[1],
if(dadata[0] << 8) | data[1]=0x4008,
The corresponding error code is
0x43and 0x14.
Command
COM_SW_ACC
Length
2
data[0]
0x42
data[0]
COM_READING
Controller response
Length
1
data[0]
Current throttle switch status
Description: Getting Throttle switch status, 1 – active, 0 – inactive. COM_READING constant is
defined as 0.
data[0]M
7
6
5
4
3
2
1
0
data[0]L
0x44
0x43
0x42
0x41
0x34
0x33
0x32
0x31
data[1]M
7
6
5
4
3
2
1
0
data[1]L
0x24
0x23
0x22
0x21
0x14
0x13
0x12
0x11