Make sure to investigate the code requirements to ensure compliance prior to 

operating the compressor. 

 

 

 

The owner, lessor, or operator of this compressor is hereby notified and forewarned 

that any failure to observe these safety precautions may result in injury, death 

and/or property damage.   

 

 

 

Operating Instructions 

 

This Instruction Manual is only part of the full Operations Manual that can be 

found on the Kellogg-American

                   website, 

.  

The operating instructions form part of the machine and must be made available 

to the compressor operating personnel at all times. In order to receive the 

maximum performance and long life from your compressor, the following 

instructions should be carefully read and all points regarding installation and 

operation of the unit should be noted and observed. Careful reading of the 

manual, prior to connecting anything to the motor or compressor, will pay 

dividends in long-term trouble-free operation.  

 

 

Installation Instructions 

 

Inspection: 

 

 

Check for possible damage in transit and see that the pulley turns freely by hand. 

Report any damage to delivering carrier at once.  

 

Location: 

 

 

Select a clean, dry, and lit location. In cold climates the compressor should be 

installed in a heated building. Insulate cold water or other low temperature pipes 

that pass overhead to avoid the possible collection and dripping of condensate 

onto the compressor and motor, which could cause rusting and/or motor shorting. 

Do not install compressor in a boiler room, paint spray room, or area where 

sandblasting is carried on. If air in the area where the compressor is to be installed 

is acid-laden or dust-laden the compressor intake should be piped to the outside. 

This intake pipe should be increased one pipe size for every twenty (20) feet of 

Section III                                                                                                         Pump Operation Manual 

 

 

www.kellogg-american.com

Содержание V12071-452

Страница 1: ...l sales kellogg american com Website www kellogg american com INSTRUCTION MANUAL Industrial Series Piston Air Compressor Model Number V12071 452 Part Number 001119 Pump Model LP452 Motor 7 5 HP 1 PH Air Tank 120 Gal Vertical L001119KNA K452 V12071 452 L001119KNA K452 ...

Страница 2: ...oint MUST inspect the shipment for damage 2 If the shipment is damaged the customer should note so on the freight bill 3 The Customer should request an inspector from the freight company to inspect the equipment immediately It is best to send a confirming letter with the following information a Freight Bill Number b Date Delivered with Shipper s Name Address c Description of Item s Damaged d Descr...

Страница 3: ...re gauge daily to be sure the automatic control system is operating within the proper limits 9 Periodically check all safety and relief devices for proper operation 10 Do not play with compressed air Pressurized air can cause serious injury or death to personnel 11 Be sure that no tools rags or loose parts are left on the compressor or drive parts 12 Do not use flammable solvents for cleaning part...

Страница 4: ...g of the manual prior to connecting anything to the motor or compressor will pay dividends in long term trouble free operation Installation Instructions Inspection Check for possible damage in transit and see that the pulley turns freely by hand Report any damage to delivering carrier at once Location Select a clean dry and lit location In cold climates the compressor should be installed in a heat...

Страница 5: ...l in the crankcase before starting fill crankcase to the high level mark on the sight glass with Kellogg American oil meeting the following specifications For operation in damp or humid conditions addition of rust inhibitor is recommended B Turn compressor over a few revolutions by hand to make sure all parts are free and in running condition C Check the tension of the belts D Remove tools rags an...

Страница 6: ...is is an ISO non detergent industrial lubricant with rust and oxidation inhibitors specifically formulated for reciprocating compressors Normal break in period of Kellogg air compressors is 25 hours After which the compressor oil needs to be drained and replaced with Kellogg Synthetic Lubricant Compressors must run for a 25 hour break in period using Kellogg ISO 100 oil After 25 hours thoroughly d...

Страница 7: ...ollowing intervals The hours of operation refer to average working conditions Other intervals may apply depending on these conditions Please contact LAPLANTE in this event Please record each maintenance task in the table on the last pages of these instructions This may help LAPLANTE Service to locate faults if any occur Maintenance intervals dependent on usage either after or Maintenance work Oper...

Отзывы: