14
Power Open:30%
P=Prog. <>=Scroll
Power Close:30%
P=Prog. <>=Scroll
Pow. Sl. Open:50%
P=Prog. <>=Scroll
Pow. Sl. Close:50%
P=Prog. <>=Scroll
Op.Speed: 12 cmS
P=Prog. <>=Scroll
Cl.Speed: 12 cmS
P=Prog. <>=Scroll
Sl.Sp.Op. : 8 cmS
P=Prog. <>=Scroll
Sl.Sp.Cl. : 8 cmS
P=Prog. <>=Scroll
Work Time: 120sec
P=Prog. <>=Scroll
MENU :
PARAMETERS
Field assembly & commissioning
smart slider - Field assembly & commissioning
14. Menu modus
14.2 MENU PARAMETERS
Power during opening
(*)
Power during closing
(*)
Power during opening
(*)
Power during closing
(*)
Speed during opening
Speed during closing
Speed during opening
Speed during closing
Worktime =
needed time + 5 sec
At normal speed
0 - 99 %
(30)
At normal speed
0 - 99 %
(30)
at slowing down period
0 - 99 %
(50)
at slowing down period
0 - 99 %
(50)
at normal speed
10-20 cm/sec (12)
at normal speed
10-20 cm/sec (12)
at slowing down period
4-12 cm/sec
(8)
at slowing down period
4-12 cm/sec
(8)
only for
0-120 sec
(120)
AUTO / SEMI-AUTO modus
(**)
Parameter explanation
LCD screen
factory
Additional information
Min. Max
settings
24
Keller minimal windows
®
|
997-00210
| 07-2022
Keller minimal windows
®
Содержание LD350