background image

© Keller International, LLC.

1-800-578-8772

STEP 1: Use parts 
1 and 2 from the 
page 2 parts list. 

Turn the 3
table legs
upside down
on the floor.

Position 4
wheels per
table leg in
such a way
that the wheels
can spin freely
without hitting
the sides of the
recessed wheel
enclosure.

Attach the
wheels as
shown above –
do not over
tighten the
screws.

Once the wheels (there are no locking 
wheels) are attached – turn the table 
legs right side up – remove all the 
drawers – see page 5 directions. 

Содержание KM-N094-2

Страница 1: ...e Manicure Table Shipped in 3 boxes Box 1 3 contains the 3 table legs 130 pounds Box 2 3 contains the 2 tables 40 pounds Box 3 3 contains the 2 granite tops 110 pounds Best to assemble with 2 or 3 peo...

Страница 2: ...Keller International LLC 1 800 578 8772 2 1 12 pcs 2 57 pcs 3 4 5 6 Hand Pad Pillow 1 pc 7 8 9 2 switch outlets 12 pcs 12 pcs 2 pcs 4 pcs 4 pcs...

Страница 3: ...Keller International LLC 1 800 578 8772 3...

Страница 4: ...or Position 4 wheels per table leg in such a way that the wheels can spin freely without hitting the sides of the recessed wheel enclosure Attach the wheels as shown above do not over tighten the scre...

Страница 5: ...ull Drawer OUT until it stops 2 Push DOWN on the Right Side Drawer Catch and HOLD Once the drawer is pulled OUT and both Drawer Slide Catches are HELD in their proper directions continue pulling the d...

Страница 6: ...fter the drawers are removed Use parts 3 4 5 from the parts list on page 2 to connect the 2 table tops to the 3 table legs NOTE Carefully consider the way you construct the whole unit as the electric...

Страница 7: ...ve These pies are used to center and hold your granite table tops in place see the picture at left this is the indent on the backside of the granite tops NOTE The granite tops may fluctuate between 1...

Страница 8: ...he nail table nail dryers are not included NOTE View from the Nail Technician s side Install the outlets last The outlets should be installed by a Licensed Electrician The Left and Right Legs each hav...

Страница 9: ...done to national electrical codes This is only an Example your electrician may do it differently Wiring functionality 1 The front electrical outlet is always powered with 120 volts to run the nail gri...

Страница 10: ...national LLC 1 800 578 8772 10 Part 9 switch outlets and cover plates on page 2 are provided NOTE Other parts shown above will be required in order to provide power to Nail Dryers See the wiring Diagr...

Страница 11: ...Keller International LLC 1 800 578 8772 11...

Страница 12: ...r International LLC 1 800 578 8772 12 Three 3 views of the switch and outlet wiring The outlet is always HOT but the ON OFF switch powers Outlet 2 The Black Wire in the bottom picture is from the Powe...

Страница 13: ...ure are from the Power Cord NOTE Power Cord can be replaced by hard wiring unit with ROMEX NOTE Materials not included in this unit should be supplied by your Licensed Electrician NOTE Wiring this pro...

Страница 14: ...Keller International LLC 1 800 578 8772 14 Just Example...

Отзывы: