Installation
Panel
Remove the front cover by unscrewing the four M5 Hex
screws. Using the shower fixing bracket, mark and drill holes
for shower fixing bracket on the wall of the shower cubicle
and secure bracket using the rawl plugs and screws supplied.
1
Connect blended water feed either directly to ½"BSP Solenoid
connection, or use flex hose provided with 15mm push fit
connection. For TMV2 panel, connect hot and cold feeds to
TMV2 mixer ½”BSP compression fittings. Flex hose extensions
are supplied with 15mm push fit connections. See TMV2 mixer
instructions for commissioning and servicing details.
2
Take care to ensure cables and pipes are not bent
and/or pinched when front panel is fitted. Secure front
panel with M5 Hex screws using supplied Allen key. For
TMV2 panel, fit control handle with Allen key provided.
3
4
Run the low electrical power cable from the power supply,
protected by 32A 30mA RCBO and 3A switched fused spur
in compliance with all IEEE standards and local building
standards and regulations, to the control hub. See ELECTRICAL
INSTALLATION for connecting power supply cable to hub.
!
Remember!
Always check for hidden pipes + cables before drilling.
Warning: Run water through plumbing to clear debris from pipework before connecting to Kelda panel.
Take caution when removing the front cover as the Digital push button is attached to the Control Hub with
a cable.
Mixed
water feed
connection
Timed Flow
(93001000 / 93003000)
Timed Flow TMV2
(93002000/ 93004000)
Cold feed 15mm
Hot feed 15mm
150mm