kelda 93007100 Скачать руководство пользователя страница 3

Important Safety Information

This product requires hot and cold water supply plus an 
electrical connection (see Electrical section on page 11 
for details). This product is not an electric shower.

Products manufactured by Kelda Showers are safe 
and without risk provided they are installed, used and 
maintained in good working order and in accordance 
with our instructions and recommendations.

IMPORTANT! DO NOT operate the unit if the shower 
head becomes damaged.
IMPORTANT! DO NOT restrict flow out of shower by 
placing an obstruction in front of the shower head 
nozzles.

G E N E R A L

1. 

Read all of these instructions and retain them for 
later use.

2. 

DO NOT take risks with plumbing or electrical 
equipment.

3. 

Isolate electrical and water supplies before 
proceeding with the installation.

4. 

The shower head must be cleaned regularly 
with descalant to remove scale and debris. 
The air hoses must be cleaned periodically to 
maintain performance and hygiene. PLEASE SEE 
MAINTENANCE SECTION.

5. 

This product is not suitable for mounting into steam 
rooms or steam cubicles.

6. 

The shower panel should not be installed in an 
outdoor environment, including sheltered areas.

P L U M B I N G

1. 

The plumbing installation must comply with water 
regulations, building regulations or any particular 
regulations as specified by a local water company 
or water undertakers and should be in accordance 
with BS EN 806 (Specifications for installations inside 
buildings conveying water for human consumption. 
Operation and maintenance).

2. 

IMPORTANT! The hot and cold-water supply 
pipes must be flushed to clear debris from before 
connecting to water inlets on shower.

3. 

DO NOT solder pipes or fittings within the panel 

shower, this could result in damage to the product. 
Use push fit or compression fittings.

4. 

DO NOT use excessive force when making 
connections to the mixer.

5. 

All plumbing connections must be completed before 
making the electrical connections.

6. 

Water pressure - Kelda products are designed to 
operate up to a maximum of 5 bar. If you wish to 
operate outside of this please discuss with a Kelda 
Engineer.

E L E C T R I C A L

1. 

The installation must comply with BS 7671 
‘Requirements for Electrical Installations’ (IEE wiring 
regulations), building regulations or any particular 
regulations as specified by the local electrical supply 
company.

2. 

In accordance with ‘The Plugs and Sockets etc. 
(Safety) Regulations 1994’, this appliance is intended 
to be permanently connected to the fixed wiring of 
the electrical mains system. 

3. 

A 32A 30 mA Residual Current Breaker Operator 
(RCBO) MUST be installed in all UK electric and 
pumped shower circuits. This may be part of the 
consumer unit or a separate unit.

4. 

Each shower must be connected to a 3A switched 
fused spur which is easily accessible. Switch off at 
fused spur for maintenance or if not in use. This is a 
safety procedure recommended with all electrical 
appliances.

5. 

Make sure all electrical connections are tight to 
prevent overheating.

6. 

As with all electrical appliances it is recommended 
to have the shower and installation checked at least 
every two years by a competent electrician to ensure 
there is no deterioration due to age and usage.

3

Содержание 93007100

Страница 1: ...enance and operational purposes Installation Manual and User Guide Flex Head White Glass TMV2 Thermostatic 93007100 Flex Head White Glass TMV2 Thermostatic Eco Handset 93008100 Fixed Head White Glass...

Страница 2: ...and Kelda s patented water saving technology within Includes TMV2 thermostatic temperature control and secondary ECO handset ideal for rinsing Fixed Head White Glass TMV2 Thermostatic 93009100 Surfac...

Страница 3: ...and maintenance 2 IMPORTANT The hot and cold water supply pipes must be flushed to clear debris from before connecting to water inlets on shower 3 DO NOT solder pipes or fittings within the panel sho...

Страница 4: ...0 Shower head Chrome Eco Handset 1 5m Handset Hose 240mm 1030mm Low voltage Electricity supply Control Hub Flow Sensor TMV2 Mixer Valve Water Pipe Air Pipe Hot Inlet Cold Inlet 238mm 83mm M5 Hex Fixin...

Страница 5: ...k Rear Hot Cold water feed Rear Low voltage 24V Electrical link 100 240V Mains electricity supply via the OWA 60 24V AC Transformer supplied Hot Cold water feed Top Hot Cold Feed Entry Points Rear Hot...

Страница 6: ...127mm 4 Panel Assembly x1 OWA 60 24V Power supply 300mm 1500mm HighVoltage Low Voltage 213mm 29mm Flex Head 93007100 93008100 Fixed Head 93009100 93010100 142mm 140mm Eco Handset 93008100 93010100 on...

Страница 7: ...use extensions or multiple sockets The power supply cable must never be bent or dangerously compressed 2000mm 1850mm 50mm Installation should be completed to suit the user s requirements Installation...

Страница 8: ...ing If the difference is too much then we recommend you to calibrate the valve to suit requirements of your installation as follows 1 Remove the screw handle adaptor and temperature control ring from...

Страница 9: ...t the handle adaptor and make sure the protrusion at the bottom points to the 12 o clock position Secure the screw and handles 3 Test temperature of water using thermometer once water supply has been...

Страница 10: ...ts with compression fittings provided 2 Use the two M3 Pozi head screws Flex Head or M5 Hex Head screws Fixed Head from the Head assembly and use them to mount the appropriate shower head to the Glass...

Страница 11: ...knob Cover with Chrome cap to finish Adjust the glass panel and diverter valve brackets until in position before inserting the control knob trims into the glass fascia panel as shown Screw on the fro...

Страница 12: ...Before fitting the temperature knob turn the brass ring clockwise until it stops full cold Repeat fixing method of temperature knob attachment using same method as the control knob Align the pointer o...

Страница 13: ...with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation 32A 30mA RCBO Up to 12 Showers 3A Switched Fused Spur AC 100 240V to...

Страница 14: ...alised coverage of the water spray To use the eHandset wand lift to remove it from the handset holder Selecting an Outlet Adjusting the Temperature The temperature is adjusted by rotating the lower co...

Страница 15: ...To change the fan speed settings press FAN button once There are 6 speed settings 1 6 3 To display current fan speed set press and hold FAN button for 2 seconds The number of LED flashes corresponds t...

Страница 16: ...ale Fan Overheat Protection Fan Test Function Press and hold TMR button for more than 5 seconds to run the fan independently of full shower operation In the unlikely event of the fan overheating from...

Страница 17: ...est Function p 12 If fan runs then check flow sensor is not jammed or faulty Temperature fluctuating Thermostatic control Boiler issue Check thermostatic mixer valve boiler for an issue call a special...

Страница 18: ...ken not to get bleach chlorine or other strong cleaning agents onto the stainless steel if this occurs then panel must be thoroughly cleaned down with a stainless steel cleaning agent Quarterly Hygien...

Страница 19: ...wdriver ensuring the fascia plate 2 and atomisation engine 3 are held until screw removed 3 Slowly lower fascia plate and atomisation engine 4 Carefully detach the rubber hose from the water chamber 4...

Страница 20: ...his until hoses are clean Once hoses are clean flush hoses through with fresh water Shake out any excess water and wipe dry Once fully dry replace air supply hose by gently inserting into air outlet a...

Страница 21: ...in one month from date of purchase providing that they are in good order and the packaging is unopened Note returned spares will be subject to a 15 restocking charge and authorisation must be obtained...

Страница 22: ...Notes 22...

Страница 23: ...ing Estate Chandler s Ford Eastleigh SO53 4DR UK Tel 44 0 2381 290640 Web www keldatechnology com DISPOSAL Do not dispose of with household waste Please recycle where facilities exist Check with your...

Отзывы: