If a blackout or brownout occurs the IPG20 will not retain any memory of
where in its run or stop cycle it may have been, it will simply shut down the
pump. When power resumes, the IPG20 will attempt to reboot, restart the
pump and run any timer settings from the beginning. If the power supply is
unstable a manual reboot can be done by pressing and releasing the
IPG20’s reset button.
The IPG20 has 3 X M20 cable glands. As supplied, the cable glands are
blanked off. The cable glands can accept cable from 7 to 9mm diametre.
See sketch for assembling the cable gland components. The controller is
supplied with a set of steel crimp rings. The crimp rings are to provide strain
relief for the controller’s cables. To use the crimps, place one on the cable
approximately 3 to 4mm below the end of the cable’s outer sheathing.
Crimp the two ears of the ring flat using bull nosed pliers. Pull the cable
back through the cable gland until the crimp ring’s ears are fully located
into the slots in the cable gland housing.
CABLES
BROWNOUT OR BLACKOUT
13
Rubber Plug
M20 Gland Nut
Backing Washer
Plug unused cable
glands using the
rubber plugs
(supplied). Fully
tighten the gland nut to
seal the unused cable
port.
Rubber Grommet
Controller Housing
Backing Washer
Cable 7mm to 9mm diametre
Crimp the ears of the
strain relief ring onto
the cable and pull the
cable back into the
slots in the gland
housing.