Before you install your STA-3108A1

CAUTION

Before you make any connections from an STA-3108A1 to a board in your computer, make sure that
power to your computer and any accessories is OFF.

Remember the following precautions when connecting any hardware to your system:

• Do NOT connect the STA-3108A1 to voltages above those tolerated by other boards in the system. Although the

STA-3108A1 is rated for 60 volts peak-to-peak, the board to which it is connected may be rated for a much lower
voltage. For example, KPCI-3108 analog inputs can only tolerate 35 volts peak without damage and digital I/O will be
damaged by voltages above +5V.

• Do NOT mix your data acquisition inputs with the AC line, or you risk damaging the computer. Data acquisition

systems give users access to inputs of the computer. An inadvertent short between data and power lines can cause
extensive and costly damage to your computer. The manufacturer can accept no liability for this type of accident. To
prevent this problem, use the following precautions:

— Avoid direct connections to the AC line.

— Make sure all connections are tight and sound so that signal wires are not likely to come loose and short to high

voltages.

— Use isolation amplifiers and transformers where necessary.

Figure 2
Pin connections

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

      

 

 

 

 

 

 

 

 

 

  

  

  

 

Содержание STA-3108A1

Страница 1: ... For example if pin 24 is assigned to the analog function OP0 use screw terminal 24 to attach a hardware output 0 Refer to the User s Guide for the board to which you are connecting the STA 3108A1 for detailed wiring information The STA 3108A1 has a 50 pin connector that maps the required signals to enable the use of the EXP1800 Channel Expansion 16 Channel Multiplexer Board with the KPCI 3108 The...

Страница 2: ...s are adequately trained Operators use the product for its intended function They must be trained in electrical safety procedures and proper use of the instrument They must be protected from electric shock and contact with hazardous live circuits Maintenance personnel perform routine procedures on the product to keep it operating for example setting the line voltage or replacing consumable materia...

Страница 3: ...touch the product test cables or any other instruments while power is applied to the circuit under test ALWAYS remove power from the entire test system and discharge any capacitors before connecting or disconnecting ca bles or jumpers installing or removing switching cards or making internal changes such as installing or removing jumpers Do not touch any object that could provide a current path to...

Страница 4: ...can only tolerate 35 volts peak without damage and digital I O will be damaged by voltages above 5V Do NOT mix your data acquisition inputs with the AC line or you risk damaging the computer Data acquisition systems give users access to inputs of the computer An inadvertent short between data and power lines can cause extensive and costly damage to your computer The manufacturer can accept no liab...

Страница 5: ...6 Table 2 Signal mapping STA 3108 A1 50 pin connector 3M3433 Pin Signal Pin Signal 45 XOP3 MUX7 46 XOP2 MUX6 43 XOP1 MUX5 44 XOP0 MUX4 49 GNDD 47 5V 17 CH15 CH7LO 16 CH7 15 CH14 CH6LO 14 CH6 13 CH13 CH5LO 12 CH5 11 CH12 CH4LO 10 CH4 9 CH11 CH3LO 8 CH3 7 CH10 CH2LO 6 CH2 5 CH9 CH1LO 4 CH1 3 CH8 CH0LO 2 CH0 25 GNDA 22 ODAC1 26 GNDA 20 ODAC0 28 XOP4 GEXT Note Signal names on the STA 3108A1 50 pin con...

Страница 6: ...ocation with the rubber feet on the mounting surface Use the four 4 screws to secure the panel Wiring the STA 3108A1 1 Before installing I O cables and connecting I O circuits to the STA 3108A1 refer to the User s Guide for the board s to which you are connecting the STA 3108A1 2 Attach the 1284CC cable to the 36 pin D connector 3 Attach the ribbon cable to the 50 pin connector ...