Do not touch any object that could provide a current path to the common side of the circuit under 

test or power line (earth) ground. Always make measurements with dry hands while standing on 

a dry, insulated surface capable of withstanding the voltage being measured.
For safety, instruments and accessories must be used in accordance with the operating 

instructions. If the instruments or accessories are used in a manner not specified in the 

operating instructions, the protection provided by the equipment may be impaired. 
Do not exceed the maximum signal levels of the instruments and accessories. Maximum signal 

levels are defined in the specifications and operating information and shown on the instrument 

panels, test fixture panels, and switching cards. 

When fuses are used in a product, replace with the same type and rating for continued 

protection against fire hazard. 
Chassis connections must only be used as shield connections for measuring circuits, NOT as 

protective earth (safety ground) connections. 

If you are using a test fixture, keep the lid closed while power is applied to the device under test. 

Safe operation requires the use of a lid interlock.

If a        screw is present, connect it to protective earth (safety ground) using the wire 

recommended in the user documentation.

The         symbol on an instrument means warning, risk of electric shock. Use standard safety 

precautions to avoid personal contact with these voltages.

The       symbol indicates a connection terminal to the equipment frame.

The         symbol on an instrument means caution, risk of hazard. The user must refer to the 

operating instructions located in the user documentation in all cases where the symbol is 

marked on the instrument.

The         symbol on an instrument shows that the surface may be hot. Avoid personal contact to 

prevent burns.

If this         symbol is on a product, it indicates that mercury is present in the display lamp. Please 

note that the lamp must be properly disposed of according to federal, state, and local laws.

The 

WARNING

 heading in the user documentation explains hazards that might result 

in personal injury or death. Always read the associated information very carefully before 

performing the indicated procedure.
The 

CAUTION

 heading in the user documentation explains hazards that could damage the 

instrument. Such damage may invalidate the warranty.

The 

CAUTION

 heading with the        symbol in the user documentation explains hazards that 

could result in moderate or minor injury or damage the instrument. Always read the associated 

information very carefully before performing the indicated procedure. Damage to the instrument 

may invalidate the warranty.
Instrumentation and accessories shall not be connected to humans. 
Before performing any maintenance, disconnect the line cord and all test cables. 

To maintain protection from electric shock and fire, replacement components in mains circuits 

— including the power transformer, test leads, and input jacks — must be purchased from 

Keithley. Standard fuses with applicable national safety approvals may be used if the rating and 

type are the same. The detachable mains power cord provided with the instrument may only be 

replaced with a similarly rated power cord. Other components that are not safety-related may 

be purchased from other suppliers as long as they are equivalent to the original component 

(note that selected parts should be purchased only through Keithley to maintain accuracy 

and functionality of the product). If you are unsure about the applicability of a replacement 

component, call a Keithley office for information. 
Unless otherwise noted in product-specific literature, Keithley instruments are designed to 

operate indoors only, in the following environment: Altitude at or below 2,000 m (6,562 ft); 

temperature 0 °C to 50 °C (32 °F to 122 °F); and pollution degree 1 or 2. 

To clean an instrument, use a cloth dampened with deionized water or mild, water-based 

cleaner. Clean the exterior of the instrument only. Do not apply cleaner directly to the instrument 

or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with 

no case or chassis (e.g., a data acquisition board for installation into a computer) should never 

require cleaning if handled according to instructions. If the board becomes contaminated and 

operation is affected, the board should be returned to the factory for proper cleaning/servicing. 
Safety precaution revision as of June 2017.

Содержание SourceMeter 2600B Series

Страница 1: ...Models 2634B 2635B and 2636B System SourceMeter Instruments Quick Start Guide...

Страница 2: ...high transient overvoltages often associated with local AC mains connections Certain Keithley measuring instruments may be connected to mains These instruments will be marked as category II or higher...

Страница 3: ...e associated information very carefully before performing the indicated procedure The CAUTION heading in the user documentation explains hazards that could damage the instrument Such damage may invali...

Страница 4: ...m 6562 ft above sea level Operating temperature 0 C to 50 C 70 relative humidity up to 35 C Derate 3 relative humidity 35 C to 50 C Storage temperature 25 C to 65 C Pollution degree 1 or 2 DC source o...

Страница 5: ...ence Manual Provides comprehensive information about the instrument s features operation optimization maintenance troubleshooting and programming commands Software for the Series 2600B instruments is...

Страница 6: ...he box for damage 2 Open the top of the box 3 Remove the documentation and accessories 4 Carefully lift the instrument out of the box 5 Remove the packaging insert 6 Inspect the instrument for any obv...

Страница 7: ...to alligator clip cable for the 2635B Two triaxial to alligator clip cables for the 2634B and 2636B 5 16 AWG black grounding wire 6 Three pin screw terminal connector 7 UL safety supplement not shown...

Страница 8: ...wed voltage in the system is 300 VDC Make sure any test fixture connected to the system protects the operator from contact with hazardous voltages hot surfaces and sharp objects Use shields barriers i...

Страница 9: ...ue to electric shock Do not replace detachable MAINS supply cords with inadequately rated cords Failure to use properly rated cords may result in personal injury or death due to electric shock To keep...

Страница 10: ...the socket of the supplied power cord to the power connection on the rear panel 3 Connect the plug of the power cord to a grounded AC outlet Connect power line cord Turn on the instrument Turn on the...

Страница 11: ...if the instrument is a 2634B or 2636B you see the default display screen shown below SrcA 000 000mV LimA 100 000mA AUTO Power up sequence When the instrument is turned on you should see A series of d...

Страница 12: ...he instrument has two channels 2634B or 2636B and is in dual channel display mode press the DISPLAY button once to show only the settings for SMU channel A 1 Press the SRC key You will see a blinking...

Страница 13: ...ENTER P U S H T O E D I T E N T E R to set the source value to 20 0000 V and then press the navigation wheel P U S H T O E D IT ENTER P U S H T O E D I T E N T E R to enter the selection and exit EDIT...

Страница 14: ...nge for the measured value You will briefly see the display shown below and then the main display screen reappears SrcA 20 0000 V LimA 10 0000mA AUTO Measurement function set to voltage V SrcA 20 0000...

Страница 15: ...ding of the Series 2600B functionality we recommend that first time users become familiar with the Series 2600B Reference Manual document number 2600BS 901 01 Step 6 Turn the output off When you finis...

Страница 16: ...2600B you can use a flash drive or any remote command interface If you use a flash drive it must be formatted as a FAT or FAT32 drive FAQs Where can I find updated drivers For the latest drivers and...

Страница 17: ...to the Series 2600B Reference Manual document number 2600BS 901 01 for detailed information about all features of the instrument Also see tek com keithley for support and additional information about...

Страница 18: ...00 1601 0077 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 82 2 565 1455 Russia CIS 7 495 6647564 Singapore 800 6011 473 South Africa 41 52 675 3777 Spain 00800 2255 4835 Sweden 00800 2...

Отзывы: