Installation and Configuration
KPCI-3101 — KPCI-3104 Series User’s Manual
shows an example of how to externally cascade two counters to perform a rate gen-
eration operation using user counters 0 and 1. Note that you can also cascade counters internally
using software; if you internally cascade the counters, you do not need to make the external cas-
cading connections. In this example, counter 1 gate is logic high.
Figure 3-19
Cascading counters (shown for rate generation using counters 0 and 1
and external gate 0)
shows an example of how to cascade two counters externally to perform a one-shot
operation using user counters 0 and 1. Note that you can also internally cascade counters using
software; if you internally cascade the counters, you do not need to make the external cascading
connections. In this example, counter 0 gate is logic high.
Figure 3-20
Cascading counters (shown for one-shot using counters 0 and 1 and external gate 1
STA-300 Panel
TB26
Signal Source
Digital Ground
TB29
TB28
Digital Ground
Gate 0
External
Gating
Switch
TB27
TB30
User
Counter
Output 0
User Clock
Input 1
TB25
User Clock Input 0
STA-300 Panel
TB26
Signal Source
Digital Ground
TB29
TB32
Digital Ground
Gate 1
One-Shot
Trigger
TB27
TB30
User
Counter
Output 0
User Clock
Input 1
TB25
User Clock Input 0
Содержание KPCI-3101 Series
Страница 1: ...User s Manual KPCI 3101 3102 3103 3104 Series PCI Bus Data Acquisition Boards 98150 Rev A 10 99...
Страница 10: ...iv...
Страница 15: ...1 Overview...
Страница 21: ...2 Principles of Operation...
Страница 53: ...3 Installation and Configuration...
Страница 78: ...3 26 Installation and Configuration KPCI 3101 KPCI 3104 Series User s Manual...
Страница 79: ...4 Testing the Board...
Страница 82: ...4 4 Testing the Board KPCI 3101 KPCI 3104 Series User s Manual...
Страница 83: ...5 Calibration...
Страница 86: ...5 4 Calibration KPCI 3101 KPCI 3104 Series User s Manual...
Страница 87: ...6 Troubleshooting...
Страница 94: ...6 8 Troubleshooting KPCI 3101 KPCI 3104 Series User s Manual...
Страница 95: ...A Specifications...
Страница 107: ...B Connector Pin Assignments...
Страница 111: ...C Systematic Problem Isolation...
Страница 145: ...This page intentionally left blank...
Страница 146: ...Keithley Instruments Inc 28775 Aurora Road Cleveland Ohio 44139 Printed in the U S A...