background image

• 

SCPI2700: An instrument-specifi c language that allows 
you to run code developed for Keithley Instruments Series 
2700 instruments.

• 

SCPI2701: An instrument-specifi c language that allows you 
to run code developed for Keithley Model 2701 instruments.

You cannot combine the command sets.

What cards can be used?

MODULE DESCRIPTION

7700

20-channel Differential Multiplexer Module

7701

32-channel Differential Multiplexer Module

7702

40-channel Differential Multiplexer Module

7703

32-channel High Speed Differential 
Multiplexer Module

7705

40-channel Single-pole Control Module

7706

20-channel Differential Multiplexer with Automatic 
CJC, 16 Digital Outputs, 2 Analog Outputs, and 
Counter/Totalizer

7707

32-channel Digital I/O Module with 10-channel 
Differential Multiplexer

7708

40-channel Differential Multiplexer Module with 
Automatic CJC

7709

6x8 Matrix Module

7710

20-channel Solid-state Differential Multiplexer 
with Automatic CJC

7711

2 GHz 50 Ohm RF Module

7712

3.5 GHz 50 Ohm RF Module

As delivered from Keithley Instruments, the DAQ6510 is set 
to work with the DAQ6510 SCPI command set.

To set the command set from the front panel:

1. 

Press the 

MENU

 key.

2. 

Under System, select 

Settings

.

3. 

Select the 

command set

.

4. 

You are prompted to reboot.

Содержание DAQ6510

Страница 1: ...Model DAQ6510 Quick Start Guide...

Страница 2: ...onnel may perform installation and service procedures Keithley Instruments products are designed for use with electrical signals that are measurement control and data I O connections with low transien...

Страница 3: ...ion provided by the equipment may be impaired Do not exceed the maximum signal levels of the instruments and accessories Maximum signal levels are defined in the specifications and operating informati...

Страница 4: ...ruments to maintain accuracy and functionality of the product If you are unsure about the applicability of a replacement component call a Keithley Instruments office for information Unless otherwise n...

Страница 5: ...y This DAQ offers a broad range of measurement capabilities including 15 measurement functions In addition to industry leading DC accuracies functions such as capacitance and 16 bit current and voltag...

Страница 6: ...he box 3 Remove the bag that contains the documentation standard accessories and optional accessories 4 Remove the DAQ6510 from the box 5 Remove the packaging insert 6 Inspect the instrument for any o...

Страница 7: ...e in an unknown state until they are properly initialized Make sure the design can tolerate this situation without causing operator injury or hardware damage Connect the instrument Important test syst...

Страница 8: ...ast 30 minutes to achieve rated accuracies The instrument will retain the state it was in on or off when it was disconnected from the power supply Operating the instrument on an incorrect line voltage...

Страница 9: ...0 2 Press and hold the POWER switch for two seconds to turn the instrument on The indicator next to the POWER switch shows amber in the off state and green in the on state when connected to the power...

Страница 10: ...ted choice Returns to previous screen Displays instrument function AMPS 3A 250V Activates front or rear terminals Displays the home screen Opens the main menu Opens the apps manager Opens the help tex...

Страница 11: ...Trigger terminals USB Type B port Power module Fuse module Optional communication card Optional card slot Optional card slot Ethernet port...

Страница 12: ...not apply more than 1000 VPEAK to the INPUT terminals or more than 350 VPEAK to the SENSE terminals Failure to heed this caution may result in instrument damage Do not apply more than 250 VPEAK betwe...

Страница 13: ...he front panel press the HOME key 3 On the Functions swipe screen select DCV 4 Short the connections The voltage measurements appear in the MEASURE DC VOLTAGE area of the home screen and should read a...

Страница 14: ...yboard to enter the name of the script 6 Select the OK button on the displayed keyboard The script is added to internal memory FAQs Where can I find updated drivers For the latest drivers and addition...

Страница 15: ...virtual front panel Do not turn off power or remove the USB flash drive until the upgrade process is complete 6 From the instrument front panel press the MENU key 7 Under System select Info Manage 8...

Страница 16: ...r Module 7705 40 channel Single pole Control Module 7706 20 channel Differential Multiplexer with Automatic CJC 16 Digital Outputs 2 Analog Outputs and Counter Totalizer 7707 32 channel Digital I O Mo...

Страница 17: ...s to the value that was last set for the voltage measure function When you return to the current measure function the display digits value returns to the value you set previously Next Steps Additional...

Страница 18: ...previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks tra...

Отзывы: