For safety, instruments and accessories must be used in accordance with the operating instructions. If the instruments or 
accessories are used in a manner not specified in the operating instructions, the protection provided by the equipment may be 
impaired. 

Do not exceed the maximum signal levels of the instruments and accessories. Maximum signal levels are defined in the 
specifications and operating information and shown on the instrument panels, test fixture panels, and switching cards. 

When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard. 

Chassis connections must only be used as shield connections for measuring circuits, NOT as protective earth (safety ground) 
connections. 

If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation requires the use 
of a lid interlock. 

If a 

  screw is present, connect it to protective earth (safety ground) using the wire recommended in the user documentation. 

The 

  symbol on an instrument means caution, risk of hazard. The user must refer to the operating instructions located in the 

user documentation in all cases where the symbol is marked on the instrument. 

The 

  symbol on an instrument means warning, risk of electric shock. Use standard safety precautions to avoid personal 

contact with these voltages. 

The 

  symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns. 

The 

  symbol indicates a connection terminal to the equipment frame. 

If this 

  symbol is on a product, it indicates that mercury is present in the display lamp. Please note that the lamp must be 

properly disposed of according to federal, state, and local laws. 

The 

WARNING

 heading in the user documentation explains hazards that might result in personal injury or death. Always read 

the associated information very carefully before performing the indicated procedure. 

The 

CAUTION

 heading in the user documentation explains hazards that could damage the instrument. Such damage may 

invalidate the warranty. 

The 

CAUTION

 heading with the 

  symbol in the user documentation explains hazards that could result in moderate or minor 

injury or damage the instrument. Always read the associated information very carefully before performing the indicated 
procedure. Damage to the instrument may invalidate the warranty.   

Instrumentation and accessories shall not be connected to humans. 

Before performing any maintenance, disconnect the line cord and all test cables. 

To maintain protection from electric shock and fire, replacement components in mains circuits 

— including the power 

transformer, test leads, and input jacks 

— must be purchased from Keithley. Standard fuses with applicable national safety 

approvals may be used if the rating and type are the same. The detachable mains power cord provided with the instrument may 
only be replaced with a similarly rated power cord. Other components that are not safety-related may be purchased from other 
suppliers as long as they are equivalent to the original component (note that selected parts should be purchased only through 
Keithley to maintain accuracy and functionality of the product). If you are unsure about the applicability of a replacement 
component, call a Keithley office for information. 

Unless otherwise noted in product-specific literature, Keithley instruments are designed to operate indoors only, in the following 
environment: Altitude at or below 2,000 m (6,562 ft); temperature 0 °C to 50 °C (32 °F to 122 °F); and pollution degree 1 or 2. 

To clean an instrument, use a cloth dampened with deionized water or mild, water-based cleaner. Clean the exterior of the 
instrument only. Do not apply cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that 
consist of a circuit board with no case or chassis (e.g., a data acquisition board for installation into a computer) should never 
require cleaning if handled according to instructions. If the board becomes contaminated and operation is affected, the board 
should be returned to the factory for proper cleaning/servicing. 

Safety precaution revision as of June 2017. 

 

Содержание 7705

Страница 1: ...dicators and relays Figure 1 Model 7705 40 Channel Single Pole Control Module Item shipped may vary from model pictured here The 7705 includes the following features Forty independent Form A switches Two 50 pin D sub connectors for use with the Model 7788 50 Pin D Subminiature Connector Kit A Model 7788 50 Pin D Subminiature Connector Kit which includes two D sub connectors The 7705 switching modu...

Страница 2: ... to the internal digital multimeter DMM the channels cannot be connected to the backplane No channels are paired You can use the 7705 switching module to control external circuits Although the 7705 relays are latching type relays hold their state even after power has been removed all relay states are set to open a few seconds after either a power cycle or a reset command is issued You can use cont...

Страница 3: ...gnations are shown in the following table Figure 3 Model 7705 pinouts Channel designations P1000 P1001 CH PIN CH PIN CH PIN CH PIN CH PIN CH PIN 1 IN 6 8 IN 25 15 IN 39 21 IN 6 28 IN 25 35 IN 39 1 OUT 8 8 OUT 26 15 OUT 40 21 OUT 8 28 OUT 26 35 OUT 40 2 IN 10 9 IN 27 16 IN 41 22 IN 10 29 IN 27 36 IN 41 2 OUT 12 9 OUT 28 16 OUT 42 22 OUT 12 29 OUT 28 36 OUT 42 3 IN 14 10 IN 29 17 IN 43 23 IN 14 30 I...

Страница 4: ...or Channel 1 IN IN 21 OUT OUT 2 IN IN 22 OUT OUT 3 IN IN 23 OUT OUT 4 IN IN 24 OUT OUT 5 IN IN 25 OUT OUT 6 IN IN 26 OUT OUT 7 IN IN 27 OUT OUT 8 IN IN 28 OUT OUT 9 IN IN 29 OUT OUT 10 IN IN 30 OUT OUT 11 IN IN 31 OUT OUT 12 IN IN 32 OUT OUT 13 IN IN 33 OUT OUT 14 IN IN 34 OUT OUT 15 IN IN 35 OUT OUT 16 IN IN 36 OUT OUT 17 IN IN 37 OUT OUT 18 IN IN 38 OUT OUT 19 IN IN 39 OUT OUT 20 IN IN 40 OUT OU...

Страница 5: ...stem For example if 1000 V is applied to the front terminals of the instrument the switching module wiring must be rated for 1000 V Failure to recognize and observe normal safety precautions could result in personal injury or death Figure 4 Typical connections for an indicator lamp alarm and relay Installation Before operating an instrument with an accessory switching module verify that the switch...

Страница 6: ...e the DAQ6510 is turned off and disconnected from line power If the switching module is connected to a DUT make sure power is removed from all external circuitry If a card slot is unused you must install slot covers to prevent personal contact with high voltage circuits Failure to install slot covers could result in personal exposure to hazardous voltages which could cause personal injury or death...

Страница 7: ...ected to a DUT make sure power is removed from all external circuitry If a card slot is unused you must install slot covers to prevent personal contact with high voltage circuits Failure to install slot covers could result in personal exposure to hazardous voltages which could cause personal injury or death if contacted Before installing or removing a switching module make sure the DAQ6510 power i...

Страница 8: ...an measure current using the front panel or using another slot that contains a switching module that supports the AC DC and digitize current measurements If you use remote commands to attempt to measure current when configuring a channel an error is returned Reactive loads To prevent damage to the module do not exceed the maximum signal level specifications of the module For reactive loads be sure...

Страница 9: ... be connected to mains These instruments will be marked as category II or higher Unless explicitly allowed in the specifications operating manual and instrument labels do not connect any instrument to mains Exercise extreme caution when a shock hazard is present Lethal voltage may be present on cable connector jacks or test fixtures The American National Standards Institute ANSI states that a shoc...

Страница 10: ...mentation explains hazards that could damage the instrument Such damage may invalidate the warranty The CAUTION heading with the symbol in the user documentation explains hazards that could result in moderate or minor injury or damage the instrument Always read the associated information very carefully before performing the indicated procedure Damage to the instrument may invalidate the warranty I...

Отзывы: