6482-901-01 Rev. A / August 2012
Return to
7-11
Model 6482 Dual-Channel Picoammeter / Voltage Source Reference Manual
Section 7: Sweep Operation
Remote sweep operation
Staircase sweep commands
summarizes remote commands used for linear and logarithmic staircase sweep
for more details on these commands.
Table 7-2
Linear and logarithmic staircase sweep commands
Command
Description
:SOURce[1]:VOLTage:MODE SWEep
:SOURce[1]:VOLTage:STARt <n>
:SOURce[1]:VOLTage:STOP <n>
:SOURce[1]:VOLTage:STEP <n>
:SOURce[1]:VOLTage:CENTer <n>
:SOURce[1]:VOLTage:SPAN <n>
:SOURce[1]:SWEep:RANGing <name>
:SOURce[1]:SWEep:SPACing <name>
:SOURce[1]:SWEep:POINts <n>
:SOURce[1]:SWEep:DIRection <name>
:SOURce2:VOLTage:MODE SWEep
:SOURce2:VOLTage:STARt <n>
:SOURce2:VOLTage:STOP <n>
:SOURce2:VOLTage:STEP <n>
:SOURce2:VOLTage:CENTer <n>
:SOURce2:VOLTage:SPAN <n>
:SOURce2:SWEep:RANGing <name>
:SOURce2:SWEep:SPACing <name>
:SOURce2:SWEep:POINts <n>
:SOURce2:SWEep:DIRection <name>
Select channel 1 sweep mode.
Specify Channel 1 sweep start voltage (n = Voltage).
Specify Channel 1 sweep stop voltage (n = Voltage).
Specify Channel 1 sweep step voltage (n = Voltage).
Specify Channel 1 sweep center voltage (n = Voltage).
Specify Channel 1 sweep span voltage (n = Voltage).
Select Channel 1 source ranging (name = BEST, AUTO, or FIXed).
Select Channel 1 staircase sweep type (name = LINear or LOGarithmic).
Set Channel 1 number of sweep points (n = points).
Set Channel 1 sweep direction. Name = UP (sweep start to stop) or DOWN
(sweep stop to start).
Select channel 2 sweep mode.
Specify Channel 2 sweep start voltage (n = Voltage).
Specify Channel 2 sweep stop voltage (n = Voltage).
Specify Channel 2 sweep step voltage (n = Voltage).
Specify Channel 2 sweep center voltage (n = Voltage).
Specify Channel 2 sweep span voltage (n = Voltage).
Select Channel 2 source ranging (name = BEST, AUTO, or FIXed).
Select Channel 2 staircase sweep type (name = LINear or LOGarithmic).
Set Channel 2 number of sweep points (n = points).
Set Channel 2 sweep direction. Name = UP (sweep start to stop) or DOWN
(sweep stop to start).
Содержание 6482
Страница 3: ......
Страница 62: ...Section 4 Range Digits Speed and Filters In this section Topic Page Range and digits 4 2 Speed 4 4 Filters 4 6...
Страница 90: ...Section 7 Sweep Operation In this section Topic Page Sweep types 7 2 Configuring and running a sweep 7 5...
Страница 182: ...Section 14 Common Commands In this section Topic Page Command summary 14 2 Command reference 14 2...