18
FUNCTIONAL TRAINER
|
OPERATION MANUAL
Do not operate the equipment during the annual maintenance procedure. The following maintenance is recommended annually
or at the time batteries are replaced:
1. Clean:
•
Wipe any accumulated dust on the interior and exterior of the Functional Trainer using a clean shop cloth.
2.
Visual inspection of Cables (external and internal):
• Ensure that the Cables have no tears/fraying.
3.
Replace Muffler if discoloration is present.
•
Tool required: 11/16 inch (17 mm) Combination Wrench.
4. Lubricate Cylinder Rod:
• Wipe the Cylinder Rod clean and coat lightly with clean, SAE 30 motor oil, or with a silicon-based spray.
5.
Replace Air Filter if element is dirty (element turns a bright pink or red color):
•
Tools required: Small Needle Nose Pliers, Cutter Tool (to cut off flared end of tubes).
1
2
3
4
5
Figure 12. Annual Maintenance
Contact Keiser Customer Support for replacement part(s) order, or for any matters regarding the safe operation of your
Functional Trainer (see back cover for contact information).
To open the Functional Trainer,
remove the ten Phillips Screws
along the top and sides of the
Back Cover using a #2 and #3
Phillips screwdriver.
ANNUAL MAINTENANCE
1
2
3
4
5
WARNING: HIGH-PRESSURE
AIR. DISCONNECT THE EQUIPMENT
FROM THE AIR SUPPLY AND
RELEASE ALL THE AIR IN THE
EQUIPMENT (“ — ” THUMB BUTTON)
BEFORE PERFORMING ROUTINE
MAINTENANCE.