3  Electrical Installation 

 

3.1  Connection of MRG-10 

 

!!!!

  Caution 

Handle  the  front  cover  with  care  as  the  glass  panel  and  gasket  are  removable.   
The glass panel and gasket are fixed in place when the cover is screwed onto the 
case and tightened.   
The gasket provides sealing between the housing and front cover and as such the 
front cover should be securely and firmly screwed onto the case. 

 

 

1. Unscrew and remove the front cover. 
2. Pass the cable through the entry and connect it to the terminal block. 
3. Connect the shield to the ground terminal. 
4. Replace the front cover and firmly screw it onto the case. 
 

Ground

Terminal

Terminal block

+

+

-

-

Ground

Terminal

Keys

LCD

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

+
+
-
-

HART

modem

Power

Supply

Unit

Terminal block

250Ω

-

+

MRG-10

Housing

R

Содержание MRG-10

Страница 1: ...Document No KF05 001G MRG 10 User s Guide User s Guide User s Guide User s Guide...

Страница 2: ...that incorrect usage may result in death or serious injury to the operator CAUTION Indicates that incorrect usage may result in injury to the operator or damage to the equipment Warning Caution Warnin...

Страница 3: ...or of the equipment The representative or dealer of this equipment must supply this User s Guide to the user who will actually operate the equipment 4 The User s Guide should be replaced if it is lost...

Страница 4: ...2 Cables 3 2 3 3 Load 3 2 3 4 Power Supply 3 2 3 5 Grounding 3 2 3 6 Arrester replacement 3 3 4 Configuration method 4 1 4 1 Display Panel Key SW 4 1 5 Configuration 5 1 5 1 Basic Settings 5 1 5 2 Ne...

Страница 5: ...e tasks such as changing circuit boards or internal software Chapter 1 reviews some basic concepts of radar based level gauging Chapter 2 describes how to assemble a gauge and how to mount it onto a t...

Страница 6: ...4 20mA current output signal Settings can be made by a HART communicator or PC based setup software Volume calculation function Volume calculation function is based level measurement of the remaining...

Страница 7: ...suring system MRG 10 can be configured with its onboard 4 key switches a handheld terminal or remotely from a personal computer via a modem The MRG 10 is connected to a PLC or power supply unit Exampl...

Страница 8: ...requirements The antenna tip should extend past the nozzle 10 mm or more If the antenna tip is located inside the nozzle echo disturbances may be generated which will negatively affect measurement per...

Страница 9: ...are present in the radar beam Obstacles in the radar beam may reduce the measuring range 2 1 3 Key factors for measurement 1 The strength of the microwave reflection from the liquid surface is propor...

Страница 10: ...hese values are rough estimates and are strongly influenced by the measuring conditions Calm surface 4 Cone 6 Cone 8 Cone 0 10 20 0 10 20 0 10 20 0 10 20 a b c a b c a b c m Rod a b c Turbulent surfac...

Страница 11: ...6 148 NPT 1 1 2 364 100 148 38 Rod Short Rod Long Extended Part 148 238 176 106 226 346 215 265 188 140 92 154 52 4 Cone Antenna 6 Cone Antenna 8 Cone Antenna 2 2 Dimensions Weights MRG 10 except ante...

Страница 12: ...MRG 10 gauge is mounted with a flange of the following specifications Cone antenna Rod antenna Maximum thickness 29mm ANSI Class 150 8 2 3 Tools The following tools are needed for installation of MRG...

Страница 13: ...required for installation of the cone antenna 2 Mount the flange on top of the cone plate Secure the flange with the locking nut Make sure that the nut is fitted tightly to the flange Warning Make sur...

Страница 14: ...hen the MRG 10 is installed on pressurized tanks 3 Carefully insert the antenna adapter of the transmitter into the sleeve Secure the antenna adapter with the union nut Make sure that the antenna adap...

Страница 15: ...nical Installation Mechanical Installation Mechanical Installation 2 8 2 5 Mounting rod antenna Warning Do not damage antenna Damaged antenna may cause gas leakage if the MRG 10 is installed on a pres...

Страница 16: ...hanical Installation Mechanical Installation 2 9 Fix rod antenna to flange Place the gasket on the tank nozzle Carefully fit the flange and the cone antenna on the tank nozzle Tighten the assembly wit...

Страница 17: ...pipe or ladder Microwave reflections from elongated metal objects such as thin pipes or ladders rungs are largest when the axis of such objects are in parallel with the electric field The orientation...

Страница 18: ...am 3 Center of the Tank When the MRG is installed at the center of the tank measurement may be adversely affected or become unstable because of microwave side lobes non main beams Thus center of tank...

Страница 19: ...tank wall to avoid influences from edge reflections off channel walls and the liquid surface For flat wall tank applications install the MRG so the axis of the electric field is perpendicular to the t...

Страница 20: ...ver is screwed onto the case and tightened The gasket provides sealing between the housing and front cover and as such the front cover should be securely and firmly screwed onto the case 1 Unscrew and...

Страница 21: ...ed twisted pair for connection Cross sectional area of conductor is 0 2 2 5mm2 AWG24 14 Cable entry 2 M20 1 5 cable diameter 10mm max 3 3 Load Minimum load for HART 250 Maximum load Non Ex 900 EX 540...

Страница 22: ...Loosen the 4 screws indicated by the arrows in the schematic below and remove the LCD panel Step 2 Loosen the Arrester PWB fixing screw indicated by the arrow Step 3 Remove and replace the Arrester PW...

Страница 23: ...de the menu number or registered data is displayed 4 1 2 Key SW 1 ENT Enter key Changes display from measurement mode to configuration mode Moves to the lower layer from main menu to sub menu Moves th...

Страница 24: ...ration mode 3 ENT 1 1 4 1 2 5 1 3 6 1 4 7 ENT 10 000 Default value 8 ENT 10 00 0 0 blinks 9 5 10 00 5 5 Push 5 times 10 ENT 10 0 0 5 11 3 10 0 7 5 12 ENT 10 0 75 13 2 10 2 75 14 ENT 1 0 275 15 4 1 6 2...

Страница 25: ...l operation mode 2 ENT 1 3 2 3 Volume Main menu 4 ENT 3 1 5 3 3 4 Volume point Sub menu 6 ENT 320 Volume point 1 7 321 Volume point 2 8 ENT 000 00 Default value 9 ENT 000 0 0 0 blinks 10 7 000 0 7 7 P...

Страница 26: ...in Feet units Note When Measuring Unit is changed units of other parameters also change 1 4 G parameter distance between flange reference point and measuring reference point Parameter Default Value D...

Страница 27: ...Value Description 3 000 23 000 Level 0 000 Parameter range in metric m units 3 000 23 000 Ullage 0 000 Parameter range in metric m units 0 000 100 000 Volume 0 000 0 000 100 000 Amplitude 0 000 dB Wh...

Страница 28: ...0 Parameter range in metric m units If measurement unit is ft display will be converted to show feet units 3 4 Volume point 320 339 Parameter Default Value Description 0 99999 99 0 000 Display will be...

Страница 29: ...onverted to show feet units 3 7 Length of the tank Parameter Default Value Description 0 000 20 000 1 000 Parameter range in metric m units If measurement unit is ft display will be converted to show...

Страница 30: ...ed to show feet units 4 4 Span Calibration Parameter Default Value 0 90 1 10 1 00 5 Advanced Setting 5 1 Averaging Time Parameter Default Value Description 1 120 10 Measuring value is averaged in acco...

Страница 31: ...ngth echo defined as surface echo 1 First Echo First echo defined as surface echo 5 7 Bottom Visible Parameter Value Description 0 Bottom Visible When tank bottom echo is larger than surface echo such...

Страница 32: ...ow feet units 6 3 Amplitude threshold 610 619 Parameter Default Value Description 0 10000 0 1 100dB If you create a noise table incorporating settings 6 1 6 3 you can produce a line chart such as that...

Страница 33: ...echo re search 7 3 User Reset Parameter Value Description 0 1 Initialization Initialized by 1 setting 7 4 Error Status Indication Error status E 00 No error E 01 Internal ROM Error E 02 Internal RAM E...

Страница 34: ...ottom of tank C is normally set to 0 If it is necessary to measure negative level please set the distance H Set the distance from ref point to measurement range see 5 2 1 Parameters of tank dimensions...

Страница 35: ...mber and click the set button When communication is completed successfully ID Version No and Product Name will appear in the boxes 3 By selecting other tabs such as the sample below you can set any pa...

Страница 36: ...ret these echoes as coming from the liquid surface Set up H to avoid this problem All echoes within this area would be outside of the measuring range and ignored 5 3 2 Noise Table If there are disturb...

Страница 37: ...1 you will need to set data 610 619 for amplitude values 6 Amplitude points must correlate to the distances defined under 6 2 Select table address ex 610 and enter amplitude data then click ENT to com...

Страница 38: ...nd this function will become invalid Also by using the PC configuration software you can add or change the position of the noise table with a right click 1 On the Tank Spectrum tab when the START butt...

Страница 39: ...hen noise level is high over the whole range the threshold level over the entire range can be set by the noise margin parameter as shown below Noise margin is set at 13dB 10dB above 3dB default value...

Страница 40: ...Tank Table Set up Linearization Point Number It is possible to set up 20 points each for level and volume respectively in the Tank Table which are linearly interpolated between points More than two p...

Страница 41: ...panel To return to the main menu click ESC again Click ESC once more to go to the measurement mode Note When using PC configuration software enter all data in the following menu then click WRITE Setti...

Страница 42: ...rger echo from the tank bottom and the gauge can not distinguish the surface reflection echo from the bottom echo Bottom Visible Flag and Bottom Window parameters of the gauge function to avoid the tr...

Страница 43: ...n if obstacles are located near to the beam area measurement will not be affected Measuring coverage can be extended to low dielectric constant liquids 2 Disadvantages Material of the pipe metal etc m...

Страница 44: ...h YLow XHigh XLow F Span calibration value XHigh High reference level value XLow Low reference level value YHigh High measured level value YLow Low measured level value 5 9 3 3 Offset compensation Off...

Страница 45: ...to 3m R C G 20m H 1 7 0 to 23m Offset of level value on LCD 1 8 99 999 99 999 m Analog Output Parameter 2 1 0 Level 1 Ullage 2 Volume 3 Amplitude dB Minimum Output 2 2 3 to 23m level Ullage 0 to 100 V...

Страница 46: ...2 2mA Offset Calibration 4 3 1 to 1m Span Calibration 4 4 0 9 to 1 1 Averaging Times 5 1 1 to 120sec Noise Margin 5 2 0 10000 1 100 dB Research Delay 5 3 1 to 120sec Alarm Delay 5 4 1 to 120sec Bottom...

Страница 47: ...m 65 Serial communication HART communication Key switch 4 keys for configuration Display 5 digit LCD and bar graph Power Supply voltage 16 28 VDC Ex 16 36 VDC Non Ex Specification for HART Ripple 47 1...

Страница 48: ...ture effect 0 01 10 K Free space reflection from flat metal surface ambient temperature 25 C 77 F atmospheric pressure Environment resistance Ambient temperature 20 70 C 40 158 F Storage temperature 4...

Страница 49: ...60079 0 2006 EN 60079 11 2007 EN 60079 26 2004 Cable Connection Cable type Shielded twisted pair Cross section area of cable 0 2 2 5 mm2 AWG24 14 Cable entry 2 M20X1 5 NPT 1 2 cable dia 6 5 9 mm Groun...

Страница 50: ...cation address Check the cable and HART modem connections and make sure that correct cable and resistor are used Display Panel window is blank Check the power supply Check the status of the gauge in t...

Страница 51: ...CATION NON HAZARDOUS LOCATION MRG 10 Intrinsic Safety Parameters Ex ia IIC T4 Parameters Ui 28V Ii 93mA Pi 0 65W Ci 0 Li 0 Ambient Temperature Limits 20 Ta 60 deg C CONTROL DRAWING 2008 2 8 5198 5640...

Страница 52: ...Safety Instructions Microwave Radar Gauge MRG 10 IMQ 08 ATEX 003 II 1 2 GD II 2 G Ex ia IIC T4...

Страница 53: ...out according to the EN60079 17 Only approved spares supplied by the manufacturer or approved agent should be used 5 Ambient temperature range This equipment is certified for use in ambient temperatur...

Страница 54: ...an internal limiting resistor of 300 ohm minimum This equipment is not insulated from earth due to the use of surge light protection provided by installation 9 Degree of Protection This equipment if c...

Страница 55: ...y 2009 1st Edition Control Division I 2 16 46 Minami Kamata Ohta ku Tokyo 144 8551 Japan TEL 81 3 3737 8621 FAX 81 3 3737 8665 Web http www tokyo keiki co jp Copyright 2009 by TOKYO KEIKI INC All righ...

Отзывы: