3 Installation
iStoragE B5-S1
User Manual
28
Ensure that the installed wall is flat and horizontal. If not, please use gasket to make the wall horizontal.
----End
3.9 Check the Installation
After installation, check the following items:
Check if the connection of DC input, AC output and communication wire are right.
Check if the iStoragE B5-S1 product is installed firmly.
Check if all the wiring are tightened.
3.10 Startup/Shutdown Procedure
Startup Procedure
After the battery is connected to the inverter, long press the ON/OFF button on the side of the battery
for 1S, the battery front panel indicator will light up, then the battery enters the standby state. After
the inverter is turned on, the battery indicator will change from flicker to constant light, and you can
view and set the battery information after connecting to APP.
Shutdown Procedure
Press the side ON/OFF button twice, the battery indicator will change from constant light to flicker,
at this time the battery is in standby state, after the inverter is turned off, disconnect the power
completely, wait for about 2 minutes, the battery will shut down and the indicator will go out. The
ON/OFF button position of the battery is shown in below.
Figure3-26 Battery ON/OFF button position