 G40 with 4 x Submersible Pumps Instruction Manual  

 

Page 

6

 of 

11

 

www.KegLand.com.au 

Last Updated 28/07/2021 3:15 PM

 

 

Changing the Reservoir Set Temperature on the STC-1000 

1.

 

Hold the 

S

 button until F1 displayed on the screen. 

2.

 

Press 

S

 again which will enter the temperature adjustment mode 

3.

 

Then simultaneously hold 

S

 and the up/down button to alter the set 

temperature of the reservoir. 

4.

 

The reservoir set temperature will be saved and the actual measured 
temperature of the reservoir will be displayed after a few seconds. 

To change any settings on the temperature controller for the reservoir such as 
temperature hysteresis or calibration refer to this instruction manual 

https://www.kegland.com.au/media/pdf/stc1000%20instructions.pdf 

Submersible Pump Temperature Controller Operation 

Turning On/Off the Temperature Controllers 

To turn the temperature controller On/Off, hold the 

Down

 button for 3 seconds. 

 

 

 

 

 

 

Temperature Controller Set Point Adjustment 

5.

 

Hold the 

Up

 button for 3 seconds. A number will begin flashing on the display, this flashing 

number is your set temperature. 

6.

 

Press the 

‘Down’

 button 

to decrease the set temperature and press the ‘Up’ button to 

increase the set temperature. 

Parameter Adjustment 

1.

 

Hold the “Up” and “Down” 

buttons simultaneously for 3 seconds. The first menu code FO 

will appear on the display. 

2.

 

Press the “Up” or “Down” buttons to cycle through the parameters F0

-F12 

3.

 

Press both the “Up” and “Down” buttons simultaneously to alter the parameter which 

appears on the display. 

4.

 

Pres

s the “Up” or “Down” buttons to change the set value of the parameter selected.

 

If there is no key operation within 5 seconds then the parameter will be set with the displayed value. 
The parameters which can be modified are outlined below. 

Содержание G40

Страница 1: ...x Submersible Pumps Instruction Manual Page 1 of 11 www KegLand com au Last Updated 28 07 2021 3 15 PM G40 With 4 x Submersible Pumps Instruction Manual KL13499 KegLand Distribution PTY LTD www KegLa...

Страница 2: ...IS NOT INTENDED FOR COOLING WORT FROM BOILING TEMPERATURES USING THE CHILLER TO COOL FROM BOILING TEMPERATURES COULD OVERLOAD THE COMPRESSOR AND VOID WARRANTY WARNING ENSURE THAT THERE IS ALWAYS ATLEA...

Страница 3: ...ind an IEC cable castor wheels and screws brass push in fitting for the drainage pipe and an STC 1000 instruction manual Assembly Assemble the Reservoir Drainage Outlet Attach the inch brass fitting o...

Страница 4: ...hour before turning it on to allow the refrigerant to settle Install the temperature probes Simply push the temperature probe male connector into the socket underneath each temperature controller Att...

Страница 5: ...ir which is dependent on a number of factors including heat ingress into the entire system insulation of the glycol lines ambient temperature the number of kegs being cooled and the temperature of the...

Страница 6: ...ontroller Operation Turning On Off the Temperature Controllers To turn the temperature controller On Off hold the Down button for 3 seconds Temperature Controller Set Point Adjustment 5 Hold the Up bu...

Страница 7: ...erior of the G40 3 Attach 10mm ID silicone tube KL18142 to the first OUT barb and either loop this back into the IN barb or run it to a fermenter and then back into the IN barb 4 Plug the G40 in using...

Страница 8: ...rmenter being controlled 6 Set the temperature on the temperature controller to the set temperature of fermentation 7 Set the temperature on the STC 1000 for the reservoir to 2 C if using glycol If yo...

Страница 9: ...umps may not be powerful enough to overcome the head pressure or resistance in the long cooling coils within the fermenter If planning to cool large jacketed fermenters we would suggest using a more p...

Страница 10: ...evice and the G40 chiller Step 2 Locate and cut the active wire to your heating device see diagram to the right Most active wires are brown or red but this should be double checked with an electrician...

Страница 11: ...allation or operating procedure not in accordance with installation and operating guidelines as described in the instruction manual To lodge a warranty claim in Australia please forward as many visual...

Отзывы: