 Collection Container Removal 

 

It is extremely important that if you have wort in the collection container attached that you keep 
the butterfly valve open during the entirety of the fermentation process.

 The butterfly valve should 

only be closed once fermentation has ceased which is to be determined by three consecutive days of 
the same Specific Gravity Reading. 

To remove the collection container once fermentation has ceased it is important to depressurise 
the entire system.

 To release the pressure in the vessel, open the butterfly valve and pull the ring on 

the PRV until there is no audible hissing from the PRV. It is also a good idea to loosen one of the 
carbonation caps on the collection vessel to ensure the collection vessel is completely depressurised. 

Once the system is depressurised the butterfly valve can then be closed if there is liquid in the 
FermZilla.  Then the lid and collection container can be detached from the butterfly valve by 
loosening the tri-

clover clamp which holds the 2” tri

-clover lid in place.  

 

 

Содержание FermZilla Tri-Conical 27L

Страница 1: ...7L and 55L Instruction Manual This instruction sheet contains vital information that is related to the safe usage and handling of the FermZilla Uni Tank It is vital that you read this instruction shee...

Страница 2: ...d the PRV ensure to remove the PRV and clean it before putting the FermZilla under pressure 10 If the fermenter is scratched damaged or has been under any physical duress do not use the fermenter unde...

Страница 3: ...1 x Grommet PCO1881 Black Cap 1 x Blank PCO1881 Black Cap for Lid 1 x Three Piece Airlock 1 x Strip Stick on Thermometer 1 x Level Indicator Sticker Litres and Gallons 1 x 3 Inch tri clover to 2 Inch...

Страница 4: ...to extend the life of this o ring and threads Adding lubricant will also improve the sealing ability of the o ring 3 Place the lid onto the neck of the tank and screw down the threaded lid ring 4 Use...

Страница 5: ...e able to freely rotate around the neck of the FermZilla If they cannot rotate then it is too tight NOTE It is suggested to orientate the handle during assembly such that the exposed thread of the bol...

Страница 6: ...ted trub or hop material 5 Carbonation of small samples of product 6 Yeast culturing container The FermZilla collection container has also conveniently manufactured with heat resistant Tritan plastic...

Страница 7: ...vity Reading To remove the collection container once fermentation has ceased it is important to depressurise the entire system To release the pressure in the vessel open the butterfly valve and pull t...

Страница 8: ...g what is described as a cardboard off flavour to your final product Oxidation also results in loss of hop flavour and aroma and hence low oxygen dry hopping is great for hoppy beer styles such as NEI...

Страница 9: ...rClean gently wipe away any soiling with a soft cloth Make sure not to use harsh scrubbers that may scratch the plastic and create ideal places for batch ruining bacteria to hide 8 If there is a large...

Страница 10: ...nder with a Type 30 MK4 regulator To thoroughly pressure test the FermZilla it is best to perform a pressure decay leak test test Pressure Decay Leak Test Procedure 1 Pressurise the FermZilla to a min...

Страница 11: ...r 3 consecutive days When removing the collection container for example when dumping trub or yeast make sure to open the butterfly valve and ensure the system including the collection container is dep...

Страница 12: ...ur fermented beer You can avoid these issues by dry hopping with the collection bottle After yeast has been collected and the butterfly valve is clear of debris simply fill the collection bottle with...