Indicative Signal Description

 

Indicative 

signal 

Description 

Working status 

Display   

No Display 

Flashing 

 

Indicator light for cooling 

Working   

Stopped Working 

Compressor delay 

 

Indicator light for heat 

Working 

Stopped Working 

n/a 

 

Indicator light for high temp 

warning 

n/a 

n/a 

High Temp 

Warning 

 

Indicator light for low temp 

warning 

n/a 

n/a 

Low Temp 

Warning 

 

 

Measuring the real temp 

Measuring the real 

temp 

Stopped Measuring the real 

temp 

n/a 

 

Menu Chart

 

Menu 

Set Range 

Default 

Unit 

MODE 

COOL / HEAT 

COOL 

SET 

-40

100 

78 

 

COOL DIFF 

1.0

20.0 

6.0 

 

HEAT DIFF 

1.0

20.0 

6.0 

 

ALARM 

1.0

30.0 

5.0 

 

Compressor delay is available, delay time is 1 minute 

 

Operation Instruction: 

Temperature Control

 

Under COOL Mode: 

The condition to start the cooling equipment: RT≥SET+COOL DIFF/2:   

The condition to stop the cooling equipment : RT≤SET- COOL DIFF/2 

Remarks: Compressor delay or time between compressor stops and starts will take more than 1 minute

.   

Under HEAT Mode: 

The condition to start the heating equipment : RT≤SET- HEAT DIFF/2 

The condition to stop heating equipment : RT≤SET+ HEAT DIFF/2 

Warning Input

 

High Temp Warning: 

RT≥SET+(COOL/HEAT) DIFF/2+ALARM 

Low Temp Warning: 

RT≥SET-(COOL/HEAT) DIFF/2-ALARM

 

 

Explanation of Operation

 

COOL DIFF/HEAT DIFF can be set from 1~20 and ALARM cab be set from 1~30.    When set to 1, there would only be a 1 
degree separation from when the unit clicks off until it clicks back on.    When set to 20, there would be a 20 degree 
separation from when the unit clicks off until it clicks back on. 
 
So for example, if the temperature was set to 32 degrees and COOL DIFF was set at 6 (default), the temperature would go 
down to 29 and click off.    When it got up to 35, it would click back on again, making the unit run more often but 
maintaining a very stable temperature.    If the temperature was set to 32 degrees and the COOL DIFF was set to 20, the 
unit would run until the temperature went down to 22 and click off.    When it got up to 42, it would click back on again 
allowing the unit to run less often using less power but with much more temperature fluctuation.

 

Содержание RTC-2

Страница 1: ...ALARM RT MODE COOL HEAT BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Kegco has a policy of continuous improvement on its products and reserves the right to change mat...

Страница 2: ...www kegco com 1 888 980 4810 Diagram and Description 1 Display Panel 2 Data Wire 3 Plug 4 Hook 5 Plug Panel 6 Plug Wire 7 Button 8 Sensor 9 Suction Cup 10 Adhesive Tape...

Страница 3: ...the door of the appliance Adhesive tape is provided for mounting the display panel to the exterior of the appliance and a suction cup on the sensor wire allows you to place it inside the appliance and...

Страница 4: ...fference Press SET again to switch to HEAT DIFF When HEAT DIFF flashes press UP and DOWN to set the desired temperature difference Press SET again to switch to ALARM When ALARM flashes press UP and DO...

Страница 5: ...n 1 minute Under HEAT Mode The condition to start the heating equipment RT SET HEAT DIFF 2 The condition to stop heating equipment RT SET HEAT DIFF 2 Warning Input High Temp Warning RT SET COOL HEAT D...

Страница 6: ...ug panel sensor short circuited causing non stop working of HEAT equipment Change the sensor Plugged wrong Plugged into COOL Plug into HEAT Wrong Mode setting COOL Setting Change the setting to HEAT W...

Страница 7: ...ture 14 140F 10 60 Storage Temperature 22 185F 30 85 Operating Ambient Humidity 20 85 Display Resolution 0 1F Temperature Adjustment Step 0 5F Temperature Difference 2F Power 3W Electrical Relay Capac...