Reversing the Door Swing
Tools Required: Philips Style Screwdriver / Flat Blade Screwdriver / Hexagonal Spanner
•
It is recommended that 2 people handle the unit for door reversal.
•
Be sure the unit is unplugged and empty.
•
Tilt the unit backwards and rest it on something solid so that it will not slip. Do not lay the unit flat on its back,
as this may damage the coolant system.
•
Adjust the two leveling feet to their highest position.
•
All parts removed must be saved for reinstallation of the door.
1.
Remove the plastic covering from the top door hinge.
2.
Unscrew the three screws from the bottom bracket.
3.
Remove the foot from the opposite side.
4.
Place to one side.
5.
Slide the door downwards and off the top hinge pin. Lift and remove the
door, and place to the side.
6.
Remove the two screws from the top bracket, and transfer them to the
other side. You will first need to remove the plastic caps on the other
side.
7.
Slide the door back onto the top hinge, ensuring that the door is the
right way up.