Kegco IRRTC2 Скачать руководство пользователя страница 4

www.kegco.com

                                                                                                                                                      1-888-980-4810 

Settings: 

The full screen will show up when plugged in 

The screen will be as follows 2 seconds after plugging in 

SET

COOL   DIFF

HEAT DIFF

ALARM

RT

MODE

COOL

HEAT

:    

     

     

 

RT

 

 

1.

 

Plugged in:   

When first plugged in, the full screen will display for 2 seconds before automatically changing to the default setting screen 

which will only show RT (Real Temperature).    When there is a power outage, the unit will return to the previous settings 

when power is restored. 

2.

 

Mode selection(main menu):   

In the default display setting

, press “SET” button once to enable Mode S

election.    The display will show RT (Real 

Temperature), MODE: COOL, HEAT and 

“COOL” 

will be flashing.   

Press “SET” again

 and the program stay in 

“COOL” Mode 

or press “UP” and “DOWN” to 

switch 

between “HEAT” and

 

“COOL” mode

s. 

3.

 

Temperature setting (submenu):   

After selecting 

“COOL” or “HEAT” Mode, 

the program is now ready to set the temperature.    When 

“SET” and original 

temperature are flashing at the same time, press the 

“UP” 

or 

“DOWN” button to 

adjust to the desired temperature.    Press 

“SET” a

gain or leave it for 15 seconds and the system will automatically save the adjusted data and quit.   

4.

 

Hidden Menu:   

Press 

and hold “SET” for 3 seconds and the s

ystem will go into the Hidden Menu, show

ing “ COOL DIFF”, “HEAT DIFF” 

and 

“ALARM”.    “COOL DIFF” will be flashing

 with the temp display showing the default setting.    Press the 

“UP” 

or 

“DOWN”

 

buttons to set the desired temperature difference.   

Press “SET”

 again 

to switch to “HEAT DIFF”. 

 

When “HEAT DIFF” 

flashes

, press “UP” and “DOWN” to set the desired temperature difference

.   

Press “SET” again to switch to “ALARM”.   

When “ALARM” 

flashes

, press “UP” and “DOWN” to adjust the 

number of degrees outside the set temperature range the 

unit will allow before sounding the alarm

. Press and hold “SET” for 3 seconds

, or leave it for 15 seconds, and the system will 

automatically save the adjusted data and quit. Pressing “SET” for less than 3 seconds will continue to

 

switch among “COOL 

DIFF”, “HEAT DIFF” and “ALARM”

 settings. 

5.

 

About the display

 

 

When the system is running in 

“COOL”

 mode

, if the display shows only “MODE

: COOL", it means no power has been input 

yet; if the display shows “MODE

COOL” and the snow

flake symbol, it means the input power has been properly set; if the 

display shows “MODE: COOL” and 

the snowflake symbol is flashing, it means the system is in a compressor delay stage. 

 

When the system is running in 

“HEAT”

 mode

, if the display shows only “HEAT”, it means no power

 has been input yet; if the 

display shows 

“MODE: HEAT” and the sun symbol

, it means the input power has been properly set.   

 

Description for operating buttons

 

Button 

Operation 

Description 

Setting Environment 

SET 

Press once 

System goes into Mode Selection or Switch Mode   

Normal operating 

Press for 3 

seconds 

System goes into hidden menu, press again to switch 

between COOL DIFF, HEAT DIFF and ALARM   

Normal operating 

 

Press once 

Data adjusted up 

Under Menu setting 

 

Press once 

Data adjusted up 

Under Menu setting 

Содержание IRRTC2

Страница 1: ...ALARM RT MODE COOL HEAT BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Kegco has a policy of continuous improvement on its products and reserves the right to change mat...

Страница 2: ...www kegco com 1 888 980 4810 Diagram and Description 1 Display Panel 2 Data Wire 3 Plug 4 Hook 5 Plug Panel 6 Plug Wire 7 Button 8 Sensor 9 Suction Cup 10 Adhesive Tape...

Страница 3: ...the door of the appliance Adhesive tape is provided for mounting the display panel to the exterior of the appliance and a suction cup on the sensor wire allows you to place it inside the appliance and...

Страница 4: ...r DOWN buttons to set the desired temperature difference Press SET again to switch to HEAT DIFF When HEAT DIFF flashes press UP and DOWN to set the desired temperature difference Press SET again to sw...

Страница 5: ...n 1 minute Under HEAT Mode The condition to start the heating equipment RT SET HEAT DIFF 2 The condition to stop heating equipment RT SET HEAT DIFF 2 Warning Input High Temp Warning RT SET COOL HEAT D...

Страница 6: ...ug panel sensor short circuited causing non stop working of HEAT equipment Change the sensor Plugged wrong Plugged into COOL Plug into HEAT Wrong Mode setting COOL Setting Change the setting to HEAT W...

Страница 7: ...ture 14 140F 10 60 Storage Temperature 22 185F 30 85 Operating Ambient Humidity 20 85 Display Resolution 0 1F Temperature Adjustment Step 0 5F Temperature Difference 2F Power 3W Electrical Relay Capac...

Отзывы: