7
Keep children and visitors away. All children and visitors should be kept a safe
distance from work area.
E. Maintenance
Disconnect machine from power source when making repairs.
Check damaged parts. To read every details of trouble shooting, repair it very crefully
and make sure the operator won´t get injurt and damage the machine.
2.3 Maintenance
Empty the spark box with regular intervals and control if the suction canals need a
cleaning. Empty or change the dust bag as required. The contact wheel should be
replaced when the edges have been worn round or the tyre has been damaged. The
graphite pad on the surface grinding table is changed as required.
Fig.: 2.1
When changing the belt it is released by turning the handle (I) in anti-clock-wise
direction (see
fig.: 2.1
), the cover (J) is opened and the worn-down belt (K) is removed
by driving the belt against the direction of rotation, and the belt is removed from the
machine by the drive wheel. The new belt is fitted. It must be checked that the
direction of the arrows on the back side of the belt correpsond to the direction of
rotation. The handle (I) is turned clockwise until grinding belt is tightened. Check for
alignment by turning the grinding belt by hand and adjust with handle (D)