KEETEC TS IMO Скачать руководство пользователя страница 2

ADJUSTABLE:  NC  -  immobilization  circuit  is  connected  to  COM  and  NC  (when 
immobilizer is active, circuits is enabled and circuit is disabled if you turn ignition on. 
When immobilizer is deactivated, circuit is enabled, does not matter on ignition status).

F11. searching remote transmitter

PRE-SET:  after  door  open  -  immobilizer  will  be  deactivated  only  when  doors  are 
opened or ignition is turn on. 
ADJUSTABLE:  always  -  immobilizer  will  be  deactivated  always  if  transmitter  is  in 
range of main unit.

F12. system reset

 - system will be reset to factory settings.

VIII. SET THE CAR ALARM USING PC

The  immobilizer  TS  IMO  can  be  also  programmed  via  PC.  For  connection  with  PC 
use programming interface T PROG and for function settings use KEETEC TS 50-100 
PC  Setup  application.  Immobilizer  must  be  connected  to  the  power  supply  during 
programming.
-  install  programming  software  KEETEC  TS  50-100  PC  Setup  (driver  for  interface  T 
PROG must be installed firstly).
- connect immobilizer with PC via T PROG and launch TS 50-100 PC Setup.
- select COM port, which is allocated to the programming cable T PROG and select 
the language
- click on 

Load 

to view actual settings of car alarm

-  change  settings  of  immobilizer  and  click  on 

Apply

.  New  values  will  be  saved  to           

immobilizer and system is now programmed
- if you want to set immobilizer to factory settings, click on 

Default

 and after loading 

factory settings values, save them by clicking on 

Apply

- it is possible to set security PIN code via PC Setup. Click on 

Load

 to load actual PIN 

code
- enter new PIN code to the window 

New

 

- enter same digits to the window 

Confirm

 and click on 

Apply

- end programming by click on 

End

The immobilizer TS IMO contains the memory of events. The memory stores the last 
20 events.

IX. WIRING DIAGRAM

NOTE: 

wires in harness are with black colour insulation and with white number of 

wire. Wire must be connected by wiring diagram.
You not need to connect the E-card antenna into system if you will not using E-card.
If yes, please, place the E-card antenna under dash board or steering column, for 
easy putting of E-card near to antenna.

- If you entered correct PIN code, siren will sound 1 time and LED diode lights no longer. 

if the LED will flash so many times which is the new value of first PIN number, push the 

if the LED will flash so many times which is the new value of second PIN number, push 

 Second PIN number is saved. LED will start to flash again.

if the LED will flash so many times which is the new value of third PIN number, push 

if the LED will flash so many times which is the new value of fourth PIN number, push 

- 5 seconds after entering the fourth code number LED diode will show the new PIN 

- Turn the ignition on or wait for 10 seconds after showing the new PIN code and system 

- If security mode is not activated, siren/buzzer sounds 2 times and LED lights permanently. 

- When security mode is activated (function F4), LED diode starts flashes slowly. Enter 

-  if the LED will flash so many times which is the value of first PIN number, push the 

-  if the LED will flash so many times which is the value of second PIN number, push the 

-  if the LED will flash so many times which is the value of third PIN number, push the 

-  if the LED will flash so many times which is the value of fourth PIN number, push the 
service button one time. If you entered correct PIN code, siren/buzzer sounds 2 times 

Turn  on  ignition  and  press  the  service  button  2  times  within  8  seconds.  Turn  off  the 
ignition. Siren/buzzer sounds 2 times and LED diode lights no longer. Service mode is 

Also, service mode may be activated by the E-card - turn on ignition and put the E-

Open the door and turn on the ignition. Push the valet button so many times, which is 
the value of the first number in PIN code within 8 seconds and then turn of the ignition. 

If the security mode is armed (function F4), LED will start to flash slowly. Enter the security 
mode. If you have entered correct PIN code, siren/buzzer will sound 4 times. System 

4. Push the valet button within 10 seconds so many times, that corresponds to the 

number of the function you want to set up. Siren will sound after each push of the 

5.  Turn  the  ignition  on.  Siren/buzzer  will  sound  1  or  2  times,  depending  on  which 

6. You can repeat programming by turning the ignition on. Using the same way from 

8. If 10 seconds without any action or turn ignition to off, system will chirp twice and 

Programming table

PC setup

SYSTEM DESCRIPTION

F1. activation time of kill relay

PRE-SET:  system  will  be  activated  after  120  seconds  when  ignition  is  turn  on.    (if 
auto transmit function is enabled, activation time starts when transmitter will be out 
of range).
ADJUSTABLE: system will be activated after 30 seconds when ignition is turn on.  (if 
auto transmit function is enabled, activation time starts when transmitter will be out 
of range).

F2. door sensing polarity

PRE-SET: input for door contacts react on negative (-) impulse  
ADJUSTABLE: input for door contacts react on positive (+) impulse

F3. door trigger with sound

PRE-SET: if system is active, and door are opened without deactivating system during 
30/120 seconds, then siren not hooting.    
ADJUSTABLE: if system is active and doors are opened without deactivating system 
during 30/120 seconds, then siren hooting during 30 seconds in 1 second interval.

F4. security mode

PRE-SET: security mode is deactivated  
ADJUSTABLE: security mode is activated

F5. anti-carjack mode

PRE-SET: anti-carjacking mode is  disabled  
ADJUSTABLE: anti-carjacking mode is enabled

F6. security control level

PRE-SET: system is deactivated via transmitter or E-card
ADJUSTABLE: system is  deactivated only via transmitter and E-card together. (in this 
case anti-carjacking mode not allowed).

F7. siren output polarity

PRE-SET: siren output has positive polarity  
ADJUSTABLE: siren output has negative polarity

F8. siren output type

PRE-SET: constant - output is permanently switched on when system is triggered.
ADJUSTABLE: pulse - output is switched on in short intervals when system is triggered. 

F9. relay type output No.1

PRE-SET:  NO  -  immobilization  circuit  is  connected  to  COM  and  NO  (circuit  is 
permanently disabled. It turns on only when immobilizer is deactivated). 
ADJUSTABLE:  NC  -  immobilization  circuit  is  connected  to  COM  and  NC  (when 
immobilizer is active, circuits is enabled and circuit is disabled if you turn ignition on. 
When immobilizer is deactivated, circuit is enabled, does not matter on ignition status).

F10. relay type output No.2 

PRE-SET:  NO  -  immobilization  circuit  is  connected  to  COM  and  NO  (circuit  is 
permanently disabled. It turns on only when immobilizer is deactivated). 

Prog.
menu

Functions

Default settings

1 chirps (buzzer/siren)

Adjustable

2 chirps (buzzer/siren)

F1

activation time of kill relay

120 seconds

30 seconds

F2

door sensing polarity

(-)

(+)

F3

door trigger with sound

no

yes

F4

security mode

no

yes

F5

anti-hijacking mode

no

yes

F6

security control level

transmitter or E-card

transmitter and E-card

F7

siren output polarity

“+”

“-”

F8

siren output type

constant

pulse

F9

relay type output No.1

NO

NC

F10

relay type output No.2

NO

NC

F11

searching remote transmitter

after door open

always

F12

system reset

reset

TECHNICAL PARAMETES

Supply voltage

12V +/- 25%

Operational temperature

-40°C to 80°C

Stand-by current

20mA

Working frequency

2,4 GHz

Current rating of contacts - relay No.1

20A 

Current rating of contacts - relay No.2

20A 

E-card 

antenna 

coil

LED diode with 

service button

+12V

ground

door contact (+/-)

imo 1

imo 2

T PROG interface

2

1

6

4

3

siren output (+/-)

ignition (+ACC)

purple/black

black

brown

black/white

black

brown

NO 1

NC 1

COM 1

COM 2

NC 2
NO 2

Отзывы: