ADJUSTABLE: NC - immobilization circuit is connected to COM and NC (when
immobilizer is active, circuits is enabled and circuit is disabled if you turn ignition on.
When immobilizer is deactivated, circuit is enabled, does not matter on ignition status).
F11. searching remote transmitter
PRE-SET: after door open - immobilizer will be deactivated only when doors are
opened or ignition is turn on.
ADJUSTABLE: always - immobilizer will be deactivated always if transmitter is in
range of main unit.
F12. system reset
- system will be reset to factory settings.
VIII. SET THE CAR ALARM USING PC
The immobilizer TS IMO can be also programmed via PC. For connection with PC
use programming interface T PROG and for function settings use KEETEC TS 50-100
PC Setup application. Immobilizer must be connected to the power supply during
programming.
- install programming software KEETEC TS 50-100 PC Setup (driver for interface T
PROG must be installed firstly).
- connect immobilizer with PC via T PROG and launch TS 50-100 PC Setup.
- select COM port, which is allocated to the programming cable T PROG and select
the language
- click on
Load
to view actual settings of car alarm
- change settings of immobilizer and click on
Apply
. New values will be saved to
immobilizer and system is now programmed
- if you want to set immobilizer to factory settings, click on
Default
and after loading
factory settings values, save them by clicking on
Apply
- it is possible to set security PIN code via PC Setup. Click on
Load
to load actual PIN
code
- enter new PIN code to the window
New
- enter same digits to the window
Confirm
and click on
Apply
- end programming by click on
End
The immobilizer TS IMO contains the memory of events. The memory stores the last
20 events.
IX. WIRING DIAGRAM
NOTE:
wires in harness are with black colour insulation and with white number of
wire. Wire must be connected by wiring diagram.
You not need to connect the E-card antenna into system if you will not using E-card.
If yes, please, place the E-card antenna under dash board or steering column, for
easy putting of E-card near to antenna.
- If you entered correct PIN code, siren will sound 1 time and LED diode lights no longer.
if the LED will flash so many times which is the new value of first PIN number, push the
if the LED will flash so many times which is the new value of second PIN number, push
Second PIN number is saved. LED will start to flash again.
if the LED will flash so many times which is the new value of third PIN number, push
if the LED will flash so many times which is the new value of fourth PIN number, push
- 5 seconds after entering the fourth code number LED diode will show the new PIN
- Turn the ignition on or wait for 10 seconds after showing the new PIN code and system
- If security mode is not activated, siren/buzzer sounds 2 times and LED lights permanently.
- When security mode is activated (function F4), LED diode starts flashes slowly. Enter
- if the LED will flash so many times which is the value of first PIN number, push the
- if the LED will flash so many times which is the value of second PIN number, push the
- if the LED will flash so many times which is the value of third PIN number, push the
- if the LED will flash so many times which is the value of fourth PIN number, push the
service button one time. If you entered correct PIN code, siren/buzzer sounds 2 times
Turn on ignition and press the service button 2 times within 8 seconds. Turn off the
ignition. Siren/buzzer sounds 2 times and LED diode lights no longer. Service mode is
Also, service mode may be activated by the E-card - turn on ignition and put the E-
Open the door and turn on the ignition. Push the valet button so many times, which is
the value of the first number in PIN code within 8 seconds and then turn of the ignition.
If the security mode is armed (function F4), LED will start to flash slowly. Enter the security
mode. If you have entered correct PIN code, siren/buzzer will sound 4 times. System
4. Push the valet button within 10 seconds so many times, that corresponds to the
number of the function you want to set up. Siren will sound after each push of the
5. Turn the ignition on. Siren/buzzer will sound 1 or 2 times, depending on which
6. You can repeat programming by turning the ignition on. Using the same way from
8. If 10 seconds without any action or turn ignition to off, system will chirp twice and
Programming table
PC setup
SYSTEM DESCRIPTION
F1. activation time of kill relay
PRE-SET: system will be activated after 120 seconds when ignition is turn on. (if
auto transmit function is enabled, activation time starts when transmitter will be out
of range).
ADJUSTABLE: system will be activated after 30 seconds when ignition is turn on. (if
auto transmit function is enabled, activation time starts when transmitter will be out
of range).
F2. door sensing polarity
PRE-SET: input for door contacts react on negative (-) impulse
ADJUSTABLE: input for door contacts react on positive (+) impulse
F3. door trigger with sound
PRE-SET: if system is active, and door are opened without deactivating system during
30/120 seconds, then siren not hooting.
ADJUSTABLE: if system is active and doors are opened without deactivating system
during 30/120 seconds, then siren hooting during 30 seconds in 1 second interval.
F4. security mode
PRE-SET: security mode is deactivated
ADJUSTABLE: security mode is activated
F5. anti-carjack mode
PRE-SET: anti-carjacking mode is disabled
ADJUSTABLE: anti-carjacking mode is enabled
F6. security control level
PRE-SET: system is deactivated via transmitter or E-card
ADJUSTABLE: system is deactivated only via transmitter and E-card together. (in this
case anti-carjacking mode not allowed).
F7. siren output polarity
PRE-SET: siren output has positive polarity
ADJUSTABLE: siren output has negative polarity
F8. siren output type
PRE-SET: constant - output is permanently switched on when system is triggered.
ADJUSTABLE: pulse - output is switched on in short intervals when system is triggered.
F9. relay type output No.1
PRE-SET: NO - immobilization circuit is connected to COM and NO (circuit is
permanently disabled. It turns on only when immobilizer is deactivated).
ADJUSTABLE: NC - immobilization circuit is connected to COM and NC (when
immobilizer is active, circuits is enabled and circuit is disabled if you turn ignition on.
When immobilizer is deactivated, circuit is enabled, does not matter on ignition status).
F10. relay type output No.2
PRE-SET: NO - immobilization circuit is connected to COM and NO (circuit is
permanently disabled. It turns on only when immobilizer is deactivated).
Prog.
menu
Functions
Default settings
1 chirps (buzzer/siren)
Adjustable
2 chirps (buzzer/siren)
F1
activation time of kill relay
120 seconds
30 seconds
F2
door sensing polarity
(-)
(+)
F3
door trigger with sound
no
yes
F4
security mode
no
yes
F5
anti-hijacking mode
no
yes
F6
security control level
transmitter or E-card
transmitter and E-card
F7
siren output polarity
“+”
“-”
F8
siren output type
constant
pulse
F9
relay type output No.1
NO
NC
F10
relay type output No.2
NO
NC
F11
searching remote transmitter
after door open
always
F12
system reset
reset
TECHNICAL PARAMETES
Supply voltage
12V +/- 25%
Operational temperature
-40°C to 80°C
Stand-by current
20mA
Working frequency
2,4 GHz
Current rating of contacts - relay No.1
20A
Current rating of contacts - relay No.2
20A
E-card
antenna
coil
LED diode with
service button
+12V
ground
door contact (+/-)
imo 1
imo 2
T PROG interface
2
1
6
4
3
siren output (+/-)
ignition (+ACC)
purple/black
black
brown
black/white
black
brown
NO 1
NC 1
COM 1
COM 2
NC 2
NO 2