INSTALLATION
Spirit installation manual
page 24
Connect pump cables
Figure 17 (left).
Showing mains switch in “OFF” position. In position “NO HEAT” the machine is
functional except that no power is fed to the heating elements (used for testing etc.).
(right). Showing pump cables for a pump-per-group Triplette plus the on/off switch for the LED light
(the switch is
in “OFF” position: lever pointing down), the mains cable is NOT present.
1. Make sure that the mains s
witch is in position “OFF” (see Figure 17).
2. The thinner electrical cables attached to the Spirit are the pump cables. Attach each pump cable
to its corresponding pump motor by mating the female plug on the cable from the machine to the
male plug at the pump-motor.
Figure 18. Pump cable plugs. Note that the colour coding on the cable should match the colour coding
on the reinforced hose that runs from the pump-outlet to the machine (the knee-shaped end of the
reinforced hose shown on the photo should be mounted on the machine, not the pump-outlet).
Caution!
When you accidentally swap the electric cables to the pumps (or the water supply lines
from the pumps to the machine), the pumps may remain running and/or brewing coffee is impossible.
colour coding
coffee system
steam boiler
group 1
group 2
group 3
standard machines
green
red
pump/group Duette
red
green
purple
pump/group Triplette
red
green
purple
yellow
LED light
switch
pump
machine
steam
group 2
group 1
group 3