KeepRite DLFCAB Скачать руководство пользователя страница 7

7

DIMENSIONS - OUTDOOR

 

N

  M

H  

   D 

      S

P

 

 

Fig. 3

-

Outdoor Unit

Table 12—DLFCAB / DLCCAR / DLFCHB / DLCCHR

System Size

9K

12K

9K

12K

18K

24K

30K

36K

Voltage

115/1/60

115/1/60

208/230-1-60

208/230-1-60

208/230-1-60

208/230-1-60

208/230-1-60

208/230-1-60

Height (H)

in

21.3

23.3

21.3

23.3

27.6

31.1

31.1

31.1

Width (W)

in

33.4

33.4

33.4

33.4

37.6

38.6

38.6

38.6

Depth (D)

in

12.6

12.6

12.6

12.6

15.6

16.8

16.8

16.8

M

in

10.0

10.0

10.0

10.0

13.4

14.6

14.6

14.6

N

in

30.0

30.0

30.0

30.0

35.0

36.2

36.2

36.2

P

in

21.3

21.3

21.3

21.3

22.0

24.0

24.0

24.0

S

in

11.3

11.3

11.3

11.3

14.3

15.6

15.6

15.6

NET Weight

Cooling

Only

lbs

62.8

73.9

72.8

80.5

113.6

147.7

152.1

154.4

NET Weight

Heat Pump

lbs

71.7

77.2

78.3

86

114.7

142.2

154.4

161

Table 13—DLFDAB / DLCDAR / DLFDHB / DLCDHR

System Size

9K

12K

9K

12K

18K

24K

30K*

36K*

Voltage

115/1/60

115/1/60

208/230-1-60

208/230-1-60

208/230-1-60

208/230-1-60

208/230-1-60

208/230-1-60

Height (H)

in

21.3

21.3

21.3

21.3

27.6

27.6

Width (W)

in

30.6

30.6

30.6

30.6

37.6

37.6

Depth (D)

in

12.6

12.6

12.6

12.6

15.6

15.6

M

in

10.1

10.1

10.1

10.1

13.4

13.4

14.6

14.6

N

in

28.0

28.0

28.0

28.0

35.0

35.0

36.2

36.2

P

in

20.0

20.0

20.0

20.0

22.0

22.0

24.0

24.0

S

in

11.3

11.3

11.3

11.3

14.3

14.3

15.6

15.6

NET Weight

Cooling

Only

lbs

59.5

63.9

66.2

70.6

90.4

103.6

NET Weight

Heat Pump

lbs

62.8

67.3

65.0

69.5

95.9

110.3

154.4

161.0

NOTE

: * Sizes 30 and 36 not available as Cooling Only.

Содержание DLFCAB

Страница 1: ...ON GUIDE 9 INDOOR UNIT INSTALLATION 9 Install Mounting Plate 9 Drill Hole in Wall for Interconnecting Piping Drain and Wiring 9 OUTDOOR UNIT INSTALLATION 9 Piping Connections to Outdoor Unit 9 INSTALL...

Страница 2: ...injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property...

Страница 3: ...n 3 8 1 2 3 8 1 2 1 2 5 8 5 8 5 8 Liquid Pipe size connection type in 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 Table 3 Refrigerant Information DLFCAB DLCCAR DLFCHB DLCCHR System Size 9K 12K 9K 12K 18K 24K 30K...

Страница 4: ...ype in 3 8 3 8 3 8 3 8 1 2 5 8 5 8 5 8 Liquid Pipe size connection type in 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 Table 5 Refrigerant Information DLFDAB DLCDAR DLFDHB DLCDHR System Size 9K 12K 9K 12K 18K 24K...

Страница 5: ...ation must be used as the communication wire from the outdoor unit to the indoor unit Please use a separate shielded 16GA stranded control wire CAUTION EQUIPMENT DAMAGE HAZARD Failure to follow this c...

Страница 6: ...A C B D D E E F H Fig 2 Indoor Mounting Plate Table 10 DLFCAB DLCCAR DLFCHB DLCCHR System Size 9K 12K 9K 12K 18K 24K 30K 36K Voltage 115 1 60 115 1 60 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1...

Страница 7: ...ing Only lbs 62 8 73 9 72 8 80 5 113 6 147 7 152 1 154 4 NET Weight Heat Pump lbs 71 7 77 2 78 3 86 114 7 142 2 154 4 161 Table 13 DLFDAB DLCDAR DLFDHB DLCDHR System Size 9K 12K 9K 12K 18K 24K 30K 36K...

Страница 8: ...in 6 5 0 13m min 1 8m CEILING FLOOR Fig 4 Indoor Unit Clearances CLEARANCES OUTDOOR A D B Air outlet Air inlet C E Fig 5 Outdoor Unit Clearances Table 14 Outdoor Clearances UNIT Minimum Value in mm A...

Страница 9: ...The refrigerant lines may be routed in any of the four directions shown in Fig 6 For maximum serviceability it is recommended to have refrigerant line flare connections and the drain connection on th...

Страница 10: ...ount outdoor power disconnect 2 Run power wiring from main box to disconnect per NEC and local codes Set outdoor unit in place 3 Remove field wiring cover from unit by removing screws 4 Connect condui...

Страница 11: ...n piping and wiring to the wall as required Completely seal the hole in the wall cut off the hole left right Fig 14 Remove Knockouts Mounting plate Fixing hook Mounting plate A12408 Fig 15 Hang Indoor...

Страница 12: ...n any liquid water Refer to Fig 19 and proceed as follows 1 Pump system down to 28 in of mercury and allow pump to continue operating for an additional 15 minutes 2 Close service valves and shut off v...

Страница 13: ...ts work properly 3 Does the air deflection louver function properly 4 Does the drain work OUTDOOR UNIT 1 Are there unusual noises or vibrations during operation Explain Following Items To Customer Wit...

Страница 14: ...it Terminal Block Indoor Unit Terminal Block Power to Indoor Unit Control to Indoor Unit Power to Indoor Unit Power from Outdoor Unit Control from Outdoor Unit CAUTION Attention Use Copper Conductors...

Страница 15: ...open or short circuit F2 2 Outdoor ambient sensor open or short circuit F3 3 6 Outdoor tube sensor open or short circuit F4 4 5 Exhaust sensor open or short circuit F5 5 7 Overload limit drop frequen...

Страница 16: ...national Comfort Products Lewisburg TN 37091 USA Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Edition Date 06 15 Catalog No 4...

Отзывы: