1.4 Calibrating the squaring arm scales
The top edge of the squaring arm slides left to right to enable
calibration. Use the 3mm Allen (hex) key to loosen the screw in
the back of the squaring arm if adjustment is necessary.
Slide the production stop onto the outside edge of the squaring
arm as shown.
Clamp a piece of card in the machine and move the production
stop to it.
Cut the card and measure, adjust the sliding scale so that the
production stop indicates the measured size.