5.2
Calibration
Calibrating the squaring arm scales
The top edge of the squaring arm slides left to right to enable calibration. Use the 3mm hexagon
wrench to loosen the screw in the back of the squaring arm if adjustment is necessary.
1.
Slide the production stop onto the outside edge of the squaring arm as shown.
2.
Clamp a piece of card in the machine and move the production stop to it.
3.
Cut the card and measure, adjust the sliding scale so that the production stop indicates the
measured size.
4.
Repeat the process for the other side of the machine.
❶
❷