background image

 

21 

  Effective June 2016 - 

 

 

 

               471 US Hwy 250 East, Ashland, Ohio   44805 

    PH:  419-207-9400    

FX:  419-207-8031 

 

Limited Warranty 

During the time periods and subject to the conditions hereinafter set forth, Keen Pump will repair or replace to the original 
user  or  consumer,  any  portion  of  your  new  Keen  product  which  proves  defective  due  to  defective  materials  or 
workmanship  of  Keen  Pump.    Contact  your  closest  authorized  Keen  Pump  representative  or  distributor  for  warranty 
service.  At all times, Keen Pump shall have and possess the sole right and option to determine whether to repair or replace 
defective  equipment,  parts  or  components.    Damage  caused  by  acts  of  GOD  or  conditions  beyond  the  control  of  Keen 
Pump is not covered by this warranty. 

 
WARRANTY PERIOD: 

36 months from date of manufacture. 
Start-up  reports  are  required  to  support  warranty  claims.    Warranty  effective  only  if  Keen  Pump  supplied  or  authorized 
control panels are used.  Single phase pumps must utilize Keen Pump supplied start components. 

 
THIS WARRANTY WILL NOT APPLY: 

(1)

 

To  defects  or  malfunctions  resulting  from  failure  to  properly  install,  operate  or  maintained  the  product  in 
accordance with printed instructions provided. 

(2)

 

To failures resulting from abuse, accident or negligence. 

(3)

 

To normal maintenance services and the parts used in conjunction with such service. 

(4)

 

To  products  which  are  not  installed  in  accordance  with  applicable  local  codes,  ordinances  and  good  trade 
practices. 

(5)

 

The product is used for purposes other than for what is was designed and manufactured. 

(6)

 

If  3  phase  motors  are  installed  on  a  single  phase  power  supply  using  a  phase  converter  or  if  3  phase  power  is 
supplied by only two transformers, making an open Delta system. 

 
WARRANTY EXCLUSIONS: 

Keen Pump specifically disclaims the implied  warranties of  merchantability and fitness  for a particular purpose after  the 
termination  of  the  warranty  period  set  forth  herein.    No  warranties  or  representations  at  any  time  made  by  any 
representatives of Keen Pump shall vary or expand the provision hereof. 

 
LIABILITY LIMITATION: 

In  no  event  shall  Keen  Pump  be  liable  or  responsible  for  consequential,  incidental  or  special  damages  resulting  from  or 
related in any manner to any Keen Pump product or parts thereof.  Personal injury and/or property damage may result from 
improper installation.  Keen Pump disclaims all liability, including liability under this warranty, for improper installation.  
Keen  Pump  recommends  following  the  instructions  in  the  installation  manual.    When  in  doubt,  consult  a  professional.  
Some  states  do  no  allow  the  exclusion  or  limitation  of  incidental  or  consequential  damages,  so  the  above  limitation  or 
exclusion may not apply to you. 

 
LABOR, ETC., COSTS: 

Keen Pump shall in no event be responsible or liable for the cost of field labor or other charges incurred by any customer in 
removing  and/or  reaffixing  any  Keen  Pump  product,  part  or  component  thereof  or  any  temporary  pumping  of  other 
equipment. 

 
RETURNED OR REPLACED COMPONENTS: 

Any  item  to  be  replaced  under  this  Warranty  must  be  returned  to  Keen  Pump,  or  such  other  place  as  Keen  Pump  may 
designate, freight prepaid. 
 
This warranty gives you specific legal rights and other rights which may vary from state to state. 
 
In  the  absence  of  suitable  proof  of  this  purchase  date,  the  effective  date  of  this  warranty  will  be  based  upon  the  date  of 
manufacture.  Example:  1605 = Year-Month = 2016, May.

                                                                     

P/N O&M-K(H)GS2

 

Содержание K(H)GS2

Страница 1: ...PH 419 207 9400 FX 419 207 8031 INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 2HP SEMI OPEN K H GS2 CENTRIFUGAL SUBMERSIBLE GRINDER SEWAGE PUMPS _____________________________________...

Страница 2: ...25 Standard Flow High Head w Radial Cutters INTERNAL CAPACITORS CATALOG NO HP PH VOLTS CORD DISCH KGS2 2001C 2 1 208 10 3 1 25 KGS2 2401C 2 1 240 10 3 1 25 KHGS2 2001C 2 1 208 10 3 1 25 KHGS2 2401C 2...

Страница 3: ...ACITORS CATALOG NO HP PH VOLTS CORD DISCH KGSL2 2001C 2 1 208 10 3 1 25 KGSL2 2401C 2 1 240 10 3 1 25 KHGSL2 2001C 2 1 208 10 3 1 25 KHGSL2 2401C 2 1 240 10 3 1 25 Read all instructions in this manual...

Страница 4: ...in cable or rope Do not use lifting chain cable or rope where failure could result in loss of life Examine all lifting devices chain cable or rope for damage before and after each lift Do not use any...

Страница 5: ...5 Effective June 2016 WIRING DIAGRAMS Internal Capacitors SINGLE PHASE 208 240V 10 3 CABLE WIRES OHM 208V OHM 240V WHITE 1 BLACK 3 1 0 1 6...

Страница 6: ...6 Effective June 2016 SINGLE PHASE 208 240V 10 5 CABLE WIRES OHM 208V OHM 240V WHITE 1 BLACK 3 1 0 1 6 WHITE 1 RED 2 6 2 6 8 BLACK 3 RED 2 5 2 5 2...

Страница 7: ...7 Effective June 2016 3 PHASE 208 230 460V 14 7 CABLE WIRES 230 VOLT OHM WHITE BLACK WHITE RED BLACK RED WIRES 460 VOLT WHITE BLACK WHITE RED BLACK RED...

Страница 8: ...l 56 60 Rockwell C SHAFT 416 Stainless Steel SHAFT SEAL Mechanical Main Motor Secondary Pump Silicon Carbide Rotating Face Silicon Carbide Rotating Face Silicon Carbide Stationary Face Silicon Carbide...

Страница 9: ...259 mfd 250 VAC 50 mfd 370 VAC MOTOR THREE PHASE 2 HP 3450 RPM 60 Hz Tri voltage 208 230 460 volts On Winding temperature sensor requires temperature sensor circuitry in control panel Oil Filled Class...

Страница 10: ...in basin NEVER WORK ON MOTOR OR GRINDER UNIT WITHOUT DISCONNECTING MOTOR LEAD WIRES FROM CONTROL PANEL DO NOT RELY UPON OPENING THE CIRCUIT BREAKER ONLY ELECTRICAL MOTOR OVERLOAD PROTECTION Single pha...

Страница 11: ...Check valve stuck closed or installed backwards Pump motor damaged worn Pump may be air locked Cutter loose or jammed on shaft worn or damaged Pump is noisy Grinder impeller may be rubbing against gr...

Страница 12: ...he impeller cutting bar and remove the allen head cap screw from the end of the shaft 2 Use a large screwdriver in the slot end of the shaft and tap counterclockwise on one of the large cutter vanes w...

Страница 13: ...factory STANDARD TOOLS REQUIRED Standard socket wrench set Ball peen Hammer Feeler Gauges minimum range 008 012 inches Vise grip pliers Allen head socket set Screwdrivers Wire brush CAUTION Disconnect...

Страница 14: ...go to step 13 If tolerance is beyond or under range go back to step 7 13 Place new or cleaned slicer retainer onto volute bottom 14 Make sure the impeller turns freely by hand after reassembly Some dr...

Страница 15: ...15 Effective June 2016...

Страница 16: ...16 Effective June 2016 REPAIR PARTS LIST...

Страница 17: ...17 Effective June 2016...

Страница 18: ...0317 1 02 3 K0317 1 02 19 Screw Skt Hd Allen 1 4 20UNC x 3 4 LG SST 1 SCS1 4X3 4SS 1 SCS1 4X3 4SS 20 Washer Impeller KGS series 1 K0451 1 01 1 K0451 1 01 22 Shim 5 8 ID x 1 00 OD x 005 SST 2 K0458 1 0...

Страница 19: ...6X1 1 4SS 4 CS5 16X1 1 4SS 15 Screw Cap 5 16 18UNC x 1 1 2 LG SST 4 CS5 16X1 1 2SS 4 CS5 16X1 1 2SS 16 Screw Cap 10 32UNC x 5 8 LG SST 1 CS10X5 8SS 1 CS10X5 8SS 17 Screw RD Head Drive 4 7UNC x 1 4 LG...

Страница 20: ...re Moisture Detector w resistor 1 K0138 1 01 1 K0138 1 01 35 Resistor 330k ohm 1 K0381 1 01 1 K0381 1 01 35 Sensor Moisture 1 KG2160 1 KG2160 36 Capacitor Start 216 259 Mfd 250 VAC 1 K0408 1 02 37 Cap...

Страница 21: ...ng a phase converter or if 3 phase power is supplied by only two transformers making an open Delta system WARRANTY EXCLUSIONS Keen Pump specifically disclaims the implied warranties of merchantability...

Отзывы: