background image

Home

Back

26

Home

Back

12. Contact and disposal information

Keeler Limited
Clewer Hill Road
Windsor
Berkshire SL4 4AA
England
Freephone: 0800 521 251
Tel: +44 (0)1753 857177
Fax: +44 (0)1753 827145

Keeler Instruments Inc
3222 Phoenixville Pike
Building #50
Malvern, PA 19355
USA
Toll Free: 1 800 523 5620
Tel: 610 353 4350
Fax: 610 353 7814

Disposal of old Electrical and Electronic Equipment 

(Applicable in the European Union and other European Countries with 
separate Collection Systems).

This symbol on the product or on its packaging and instructions 
indicates that it was put on the market place after August 2005 and 
that this product shall not be treated as Household Waste.

To reduce the environmental impact of WEEE (Waste Electrical Electronic
Equipment) and minimise the volume of WEEE entering landfills we 
encourage at product end of life that this equipment is recycled and reused.

If you need more information on the collection reuse and recycling then 
please contact B2B Compliance on 01691 676124 (+44 1691 676124).

EP59-19156 Issue C

Содержание Spectra Iris

Страница 1: ...Next Next Spectra Iris Indirect Ophthalmoscope Instructions for use Next Spectra Iris Indirect Ophthalmoscope Instructions for use ...

Страница 2: ...setting control 13 Page 6 Chargers battery packs and power supply 14 Power supply assembly Charging the battery pack 15 Charge time belt clip 16 7 Cleaning instructions 17 8 Specifications and electrical ratings 18 Electrical specifications Transport storage and operation 9 Annex I EMC statement and guidelines 19 10 Spare parts and accessories 24 11 Warranty 25 12 Contact and disposal information ...

Страница 3: ...ut the manufacturer s prior written approval As part of our policy for continued product development we reserve the right to make changes to specifications and other information contained in this document without prior notice Spectra Iris is a registered trademark of Keeler Ltd 2012 Copyright Keeler Limited 2012 Published in the UK 2012 ...

Страница 4: ...ating instructions carefully prior to installing or using your new indirect ophthalmoscope Please read and follow these instructions carefully 2 Introduction Thank you for purchasing the Keeler Spectra Iris Indirect We have taken the greatest care in the design development and manufacture of this product to ensure that you get many years of trouble free service However it is important that you rea...

Страница 5: ...Manufacturer s name and address This Symbol on the product or on its packaging and instructions indicates that it was put on the market place after August 2005 and that this product shall not be treated as Household Waste Type B protections against shock Mandatory action sign Follow instructions for use High voltage Trip hazard Optical radiation hazard Hot surface Non ionizing radiation This way u...

Страница 6: ...duct should not be immersed in fluids Do not disassemble or modify the battery There are no serviceable parts inside Do not dispose of battery in fire puncture or short circuit Do not use a battery that is deformed leaking corroded or visually damaged Handle a damaged or leaking battery with care If you come into contact with electrolyte wash exposed area with soap and water If it contacts the eye...

Страница 7: ... where the temperature may exceed 40 C or fall below 0 C There are no user serviceable parts inside Contact authorised service representative for further information Ensure battery orientation is correct or personal injury damage to equipment may occur Care should be taken when handling halogen bulbs Halogen bulbs can shatter if scratched or damaged Ensure device is securely held in docking statio...

Страница 8: ...lication of the need to use bright light clearly visualize ocular structure during delicate ophthalmic surgical procedure While no visible retinal lesions have been identified for ophthalmic instruments it is recommended that illumination levels be set to the minimum level necessary to perform the diagnostic function Young children and persons with diseased eyes may be at a higher risk The risk ma...

Страница 9: ...e Back 9 A 5 Setting up and using the Spectra Iris Description of the Product A Frame B Hinge C Aperture Lever D Filter Selector E Mirror Angle F Interpupillary Distance Control G Mounting Holes D C B G E C F E ...

Страница 10: ...up and using the Spectra Iris Frame A 1 Fit the Spectra Iris head unit into the frame A via the pin mounting system as shown 2 The prescription lens frame if required is fitted as shown Prescription lens frame in correct position ...

Страница 11: ...prung catch will engage with the dimples on the nose bridge This is to allow a range of adjustment to suit the users requirements 5 Once the desired position has been confirmed this can be locked more securely in position by gently tightening the screws circled Please note Care must be taken not to overtighten the screws during this process or the equipment may be damaged ...

Страница 12: ...ight so blood will appear black silhouetted against a dark background Blue Cobalt blue for fluorescein angioscopy Mirror angle control E The light is positioned vertically into the field of view by rotation of the levers E located either side of the binocular block Aperture lever C By sliding the lever C in direction of the arrows the size of the aperture can be adjusted Slide to the right to incr...

Страница 13: ... in front of each eye Place an object perhaps the thumb approximately 40cm from the face and centre it horizontally in the light patch Then close one eye Using the thumb and forefinger of the opposite hand slide the P D Control F of the open eye located directly under each eyepiece so that your object moves into the centre of the field keeping the object in the centre of the light patch Repeat for...

Страница 14: ...Home Back 14 6 Charger power supply assembly IEC 60320 TYPE 7 connector Set Plug Replace the blanking plate with the appropriate mains plug adaptor if required or use IEC 60320 TYPE 7 connector not supplied ...

Страница 15: ...s powered Place the battery pack into the charging well as shown below A yellow LED indicates battery pack s charge state as below Green LED Charging storage unit powered No yellow LED Battery charged Flashing yellow LED Top up charge Solid yellow LED Rapid charge The battery pack can be used at any time during the charging cycle and will resume charging when battery pack is placed back in the cha...

Страница 16: ...ately 4 hours on full power Turn the illumination on by rotating the dimmer control knob in an anti clockwise direction A yellow LED indicates battery pack s charge state as below Flashing yellow LED Battery requires charging Insert connector into socket as shown Belt Clip The belt clip can be used for those who prefer to carry the unit on a belt ...

Страница 17: ...xternal surface with a clean absorbent non shedding cloth dampened with a water detergent solution 2 detergent by volume or water isopropyl alcohol solution 70 IPA by volume Avoid optical surfaces b Ensure that excess solution does not enter the instrument Use caution to ensure cloth is not saturated with solution c Surfaces must be carefully hand dried using a clean non shedding cloth d Safely di...

Страница 18: ... Power supply rating 12V 2 5amps Operation Continuous Classification Class II equipment Type B protection against shock Transport storage and operating conditions Transport Storage Operation Temperature range 40 C to 70 C 10 C to 35 C 10 C to 35 C Relative humidity 10 to 95 10 to 95 30 to 75 ...

Страница 19: ...electromagnetic compatibility EMC This Section describes its suitability in terms of electromagnetic compatibility of this instrument When installing or using this instrument please read carefully and observe what is described here Portable or mobile type radio frequency communication units may have an adverse effect on this instrument resulting in malfunctioning ...

Страница 20: ...5 1 kV line s to line s 2 kV line s to earth 1 kV line s to line s N A Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycles 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 s 5 UT 95 dip in UT for 0...

Страница 21: ... for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The Keeler Spectra Iris is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes ...

Страница 22: ... from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol Note 1 At 80MHz and 800MHz the higher frequency range applies Note 2 These guide lines may not apply in all situations Electromagnetic propagation is affected by absorption a...

Страница 23: ...ions equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80MHz d 1 2 p 80MHz to 800MHz d 1 2 p 800MHz to 2 5GHz d 2 3 p 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 1 2 1 2 2 3 10 3 7 3 7 7 4 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be det...

Страница 24: ...iew Part Number Description 1201 P 6067 Large thimble depressor for Scleral Indentation 1201 P 6075 Small thimble depressor for Scleral Indentation 1205 P 7000 Spectra teaching mirror 1941 P 5350 KLED Spectra double charger 3412 P 7002 Spectra carrying case Part Number Description 1919 P 5215 Lithium battery pack 1941 P 5385 Single lithium charger includes EP29 32777 power supply 2199 P 7136 Lens ...

Страница 25: ...Your Keeler product is guaranteed for 3 years and will be replaced or repaired free of charge subject to the following Any fault due to faulty manufacture The instrument and accessories have been used in compliance with these instructions Proof of purchase accompanies any claim Please note that batteries are covered by this warranty statement for 1 year only ...

Страница 26: ...and other European Countries with separate Collection Systems This symbol on the product or on its packaging and instructions indicates that it was put on the market place after August 2005 and that this product shall not be treated as Household Waste To reduce the environmental impact of WEEE Waste Electrical Electronic Equipment and minimise the volume of WEEE entering landfills we encourage at ...

Отзывы: