KEELER LOUPES

UNDER NO CIRCUMSTANCES SHOULD THIS BE DONE BY HOLDING THE 

TELESCOPES.

•  If your Loupe Frames are fi tted with prescription lenses, you may fi nd it necessary to 

position your Loupes on the front stop of the Loupe pins to prevent the telescope from 

touching the lenses, particularly when the curvature of high-powered lenses prevent the 

Loupes from being angled fully downward.

4.3  HOW TO FIT THE LOUPE ‘FLIP UP’ LEVER

Keeler Surgical Loupes are mounted on a specially designed hinge, permitting the telescopes to 

be fl ipped up out of view when not required (Fig. 10).
To avoid touching the non-sterile Loupes, a sterilisable Loupe Flip Lever is provided with each 

pair of Loupes (spares are also available). When magnifi cation is required again, the Loupes 

may be returned to their original preset working angle. The Loupe Flip Lever is fi tted by pushing 

onto the Loupe bar (Fig. 11) and removed by twisting off.

Over a period of time the hinge tension may slacken slightly and require adjustment. Using 

a small crosshead or Phillips screwdriver, adjust the hinge screw to the required tension as 

shown (Fig. 12).

Fig.10

Fig.11

 Fig.12

Содержание LOUPES

Страница 1: ...A world without vision loss Keeler Loupes Magnification Systems INSTRUCTIONS FOR USE...

Страница 2: ......

Страница 3: ...UST LOUPES FITTED TO A HEADBAND 8 4 2 HOW TO FIT AND REMOVE LOUPES FROM A FRAME OR HEADBAND 8 4 3 HOW TO FIT THE LOUPE FLIP UP LEVER 9 4 4 THE LOUPE HEAD STRAP 10 4 5 FRAME ADJUSTMENTS 10 4 6 PROTECTI...

Страница 4: ...eeler Loupes are designed and built in conformity with Directive 93 42 EEC Regulation EU 2017 745 and ISO 13485 Medical Devices Quality Management Systems Classification CE Class I FDA Class II The in...

Страница 5: ...re safe operation of the Loupes WARNINGS Please note that the proper and safe functioning of our instruments is only guaranteed if both the instruments and their accessories are exclusively from Keele...

Страница 6: ...r Loupes are at the optimal angle to suit you 1 2 CONTRAINDICATION There is no restriction to patient population this device can be used with other than those outlined in the contraindications stated...

Страница 7: ...and 1D caps should not be re used if visibly contaminated with uids or blood 6 Manually clean all surfaces of the units using a suitable brush and de ionised water detergent solution 2 detergent by v...

Страница 8: ...will comprise of the following additional components Loupe Flip Lever Head Strap Lens cloth Case 4 SETTING UP AND USING YOUR LOUPES The aim in using Keeler Surgical Loupes is to achieve a clear circul...

Страница 9: ...satisfied that you have the best possible image tighten the telescope locking knobs Important All Keeler Surgical Loupes are accurately aligned and set for precise binocular vision Under no circumstan...

Страница 10: ...by sliding along the bar Fig 6 Note If you are using your Loupes in conjunction with a fiber optic headlamp first adjust the Loupes as described above The light may then be adjusted to illuminate the...

Страница 11: ...d on a specially designed hinge permitting the telescopes to be ipped up out of view when not required Fig 10 To avoid touching the non sterile Loupes a sterilisable Loupe Flip Lever is provided with...

Страница 12: ...reduce the working distance and are useful if you need to work in two different positions They are also a push fit 5 WARRANTY Your Keeler product is guaranteed for 3 years and will be replaced or repa...

Страница 13: ...ps for Hi Res Galilean Loupes pair 2112 P 8065 1D lens cap for Panoramic Loupes pair 2113 P 7001 Protective caps for Panoramic Loupes pair 2113 P 7000 Loupe Flip Lever pack of 7 2199 P 7216 8 OPTICIAN...

Страница 14: ...most cases the Bifocal ADD should be the same as the normal prescription However some surgeons prefer the ADD to be of a power that produces a working distance similar to that of the Loupe telescopes...

Страница 15: ...act of WEEE Waste Electrical Electronic Equipment and minimise the volume of WEEE entering landfills we encourage at product end of life that this equipment is recycled and reused If you need more inf...

Страница 16: ...2021 USA Sales Office Keeler USA 3222 Phoenixville Pike Building 50 Malvern PA 19355 USA Toll Free 1 800 523 5620 Tel 1 610 353 4350 Fax 1 610 353 7814 India Office Keeler India Halma India Pvt Ltd P...

Отзывы: