 6

EN

KSL-H by KEELER

3.  Surfaces must be carefully hand-dried using a clean non-shedding cloth.
4.  Safely dispose of used cleaning materials.

4.  NAMES OF CONTROLS AND COMPONENTS

Headrest Assembly

1.  Fixation light cable
2.  Main lamp cable (4 pin socket)
3.  Forehead rest band
4.  Patient’s eye height marker
5.  Fixation light
6.  Chinrest
7.  Chinrest height adjuster
8.  Patient grab handles
9.  Power lead, chinrest to lamp housing

KSL-H Series

10.  Lamp cover
11.  Lamp cover release screws
12.  Lever for grey (ND), blue, diffuser and red free fi lters
13.  Slit length, slit rotation and aperture control
14.  Scale for slit rotation
15.  Illumination mirror
16.  Slit offset centering knob
17.  Inclination latch 5° to 20°
18.  Slit width controls
19.  Test bar & tonometer plate mounting hole and cover
20.  Illumination arm locking knob
21.  Microscope arm locking knob
22.  Eyepiece assembly securing knob
23.  Joystick base locking knob

5

3

4

8

1

2

7

6

9

12

13

11

14

10

16

17

18

15

19

20

22

21

Содержание KSL-H

Страница 1: ...SLIT LAMP INSTRUCTIONS FOR USE H Series A world without vision loss ...

Страница 2: ......

Страница 3: ...OR USE 11 6 1 SETTING THE BINOCULARS 11 6 2 PREPARING THE PATIENT AND USING THE SLIT LAMP 12 6 3 DESCRIPTION OF FILTERS APERTURES AND MAGNIFICATIONS 13 7 ROUTINE MAINTENANCE 14 7 1 LED SYSTEMS 14 7 2 REGULARLY INSPECT THE DEVICE FOR DAMAGE OR DIRT 15 7 3 CLEANING AND CHANGING THE MIRROR 15 7 4 ELECTRICAL CONNECTIONS 15 7 5 OPTICS 15 7 6 AXLE AND MECHANICAL PARTS 15 8 WARRANTY 15 9 SPECIFICATIONS A...

Страница 4: ...ity Humidity limitation Use by date Serial number Catalogue number Medical device Translation The Keeler Slit Lamp is designed and built in conformity with Directive 93 42 EEC Regulation EU 2017 745 and ISO 13485 Medical Devices Quality Management Systems Classification CE Class I FDA Class II The information contained within this manual must not be reproduced in whole or part without the manufact...

Страница 5: ...sembly and a table top with power supply and accessory drawer The light intensity is controlled by a variable rheostat located on the XYZ translation base There are a number of selectable filters allowing the user to control the characteristics of the examination light 2 SAFETY 2 1 PHOTOTOXICITY CAUTION The light emitted from this instrument is potentially hazardous The longer the duration of expo...

Страница 6: ...y the specialized technicians of the manufacturer s Technical Service Centre or by personnel trained and authorised by the manufacturer The manufacturer declines any and all responsibility for loss and or damages resulting from unauthorised repairs furthermore any such actions will invalidate the warranty The power switch and mains plug are the means of isolating the device from the mains supply e...

Страница 7: ...portant when the unit has been stored or transported in a cold environment this can cause severe condensation to develop on the optical elements 2 3 CONTRAINDICATION There is no restriction to patient population this device can be used with other than those outlined in the contra indications stated below Slit lamps can produce discomfort in some photophobic patients due to the high illumination Ad...

Страница 8: ...es 9 Power lead chinrest to lamp housing KSL H Series 10 Lamp cover 11 Lamp cover release screws 12 Lever for grey ND blue diffuser and red free filters 13 Slit length slit rotation and aperture control 14 Scale for slit rotation 15 Illumination mirror 16 Slit offset centering knob 17 Inclination latch 5 to 20 18 Slit width controls 19 Test bar tonometer plate mounting hole and cover 20 Illuminati...

Страница 9: ...28 R type tonometer mounting hole 29 Yellow filter knob up out 30 Lock for securing magnification body 31 Magnification change drum 32 Eyepieces adjustable for PD and dioptre correction 33 Breath shield securing knob 34 Main power switch 35 Power supply unit 36 Glide plate 24 25 23 26 27 29 28 31 30 33 32 34 35 36 ...

Страница 10: ...s castors ensure the following before moving it to another location 1 The table is at its lowest position 2 The power cord is removed 3 The Slit Lamp arm and base locking knobs are tightened 4 The runner covers are securely located 5 The system is moved by grasping it at its lowest practical point 5 1 TABLE TOP AND BASE ASSEMBLY PROCEDURE 1 Attach the Slit Lamp table top to your table leg using th...

Страница 11: ...igned Attach the tower to the base using the hex bolt removed earlier and tighten using the wrench provided 2 Carefully fit the microscope body to the arm ensuring it is pushed to the stop Tighten using the securing knob on the side 3 Attach the breath shield as indicated in the images below Note Images show assembly on KSL Z however the process is identical and applicable to KSL H a b c slide to ...

Страница 12: ...on 9 4 Power Supply page 20 3 Connect the mains power to the Slit Lamp transformer using the power lead provided Only a hospital grade 3 conductor electrical power supply cable must be used For USA and Canada Detachable power supply cord set UL listed type SJE SJT or SJO 3 conductor not smaller than 18 AWG Plug cable and ground lead connection of the socket have to be in perfect condition 5 4 FITT...

Страница 13: ...nsures exact centering of the prism with the left objective 8 To obtain an image as clear and as free of reflexes as possible the angle between the illumination and the microscope should be about 60 and the slit diaphragm should be fully opened 9 When not in use the instrument is swung around and secured in a notch position to the right of the microscope 6 INSTRUCTIONS FOR USE 6 1 SETTING THE BINO...

Страница 14: ...inus one 1 or minus two 2 dioptres 6 2 PREPARING THE PATIENT AND USING THE SLIT LAMP Parts of the slit lamp coming in to contact with the patient should be cleaned in accordance with these instructions prior to the examination Keeler recommends the use of disposable hygienic chinrest tissues on the chinrest before the patients place their chin on it Never use the instrument if visibly damaged and ...

Страница 15: ...umination Tightening the knob will re centre the slit image in the centre of the visual field of the microscope 8 The slit image is made vertical or given a pre set angle by means of the inclination latch 17 notches at 5 10 and 15 20 9 When using the blue filter 12 the user may wish to insert the yellow barrier filter 29 The yellow barrier filter is out when the knob is up in when it is down 10 Wh...

Страница 16: ...ce outlined below should only be carried out once the main power cable has been disconnected If you have any problems that are not covered by the procedures described below contact Keeler Ltd or your local supplier 7 1 LED SYSTEMS LED s typically have a life exceeding 10 000 hours of continuous use and therefore can be considered as a non consumable item that will not require changing by a user Wh...

Страница 17: ...cables and connectors To access the bulb connections see earlier in this section for guidance 7 5 OPTICS The optics should be wiped clean of any loose dirt or debris with a suitable dust brush then cleaned with a soft dry lens cloth washed linen or other non abrasive lens cleaning material The condenser lens beneath the illumination lamp will require cleaning to access this remove the lamp as deta...

Страница 18: ...ng or using this instrument please read carefully and observe what is described here Portable or mobile type radio frequency communication units may have an adverse effect on this instrument resulting in malfunctioning 9 1 ELECTROMAGNETIC EMISSIONS Guidance and manufacturer s declaration electromagnetic emissions The Keeler Slit Lamp is intended for use in the electromagnetic environment specified...

Страница 19: ... 1 kV line s to line s 2 kV line s for input output line s 1 kV line s to line s 2 kV line s for input output line s Mains power quality should be that of a typical professional healthcare facility Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 UT 0 0 5 cycle 0 45 90 135 180 225 270 315 UT 0 1 cycle UT 70 25 30 cycles 0 UT 0 250 300 cycle UT 0 0 ...

Страница 20: ...and people 1 Field strengths from fixed transmitters such as base stations cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the locatio...

Страница 21: ...frequency applies These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 9 4 TECHNICAL SPECIFICATIONS Optical System Type Galilean converging binoculars 8 Magnification Rotating drum change x6 x10 x16 x25 x40 Eyepiece x12 5 Field of view 34 22 14 8 5 and 5 5 mm Interpupillary distance 49 0 to 77mm Obj...

Страница 22: ... provide at least two means of protection Power Supply Power supply unit Switch mode 100V 240V input 10 multi plug compliant to EN IEC 60601 1 EN IEC 61000 6 2 EN IEC 61000 6 3 Fuse T2 5AH 250V Power supply output 12V DC 2 5 amps must be EN IEC 60601 compliant Complies with Electrical Safety Medical EN IEC 60601 1 Electromagnetic compatibility EN IEC 60601 1 2 Ophthalmic instruments Fundamental re...

Страница 23: ...060 hPa 700 hPa TRANSPORT CONDITIONS 50 C 40 C 95 10 1060 hPa 500 hPa Vibration sinusoidal 10 Hz to 500 Hz 0 5g Shock 30 g duration 6 ms Bump 10 g duration 6 ms This instrument does not meet the temperature requirements of ISO 15004 1 for storage and transportation Do not store or transport this instrument in conditions where the temperature may rise above 50 C ...

Страница 24: ...tal Keeler Applanation Tonometer 2414 P 2032 Keeler D KAT R Type Digital Keeler Applanation Tonometer 2414 P 2042 11 PACKAGING AND DISPOSAL INFORMATION Disposal of old electrical and electronic equipment This symbol on the product or on its packaging and instructions indicates that this product shall not be treated as household waste To reduce the environmental impact of WEEE Waste Electrical Elec...

Страница 25: ......

Страница 26: ...ice Keeler USA 3222 Phoenixville Pike Building 50 Malvern PA 19355 USA Toll Free 1 800 523 5620 Tel 1 610 353 4350 Fax 1 610 353 7814 India Office Keeler India Halma India Pvt Ltd Plot No A0147 Road No 24 Wagle Industrial Estate Thane West 400604 Maharashtra INDIA Tel 91 22 4124 8001 China Office Halma China Group 名称 沃迈 上海 机电有 限公司 地址 上海市闵行区金都路 1165弄123号23幢一号厂房 三层B座 电话 021 6151 9025 Visiometrics S ...

Отзывы: