3) Install Main Module

(1

Drill holes with a drill (diameter of 8mm) at the cross cursor of letters (A1, A2, A3 and A4) and then strike the 

expansion screw tubes into the holes (4pcs in total).

[

Notice

]

 

The right part o

n

 the main module is for inserting hard disks, so when hanging it, reserve at least 

400mm distance from it to the wall or other obstacles.

There

 

are

 

dial

 

switches

 

and

 

tags

 

at

 

the

 

top

 

right

 

corner

 

on

 

the

 

back

 

of

 

the

 

main

 

module

 

and

 

the

 

docks

The

 

tags

 

are

 

indicated

 

below

When installing the device, please adjust the dial switches according to the instructions. 

For example, before installing the main module, dial both SW1 and Sw2 switches to OFF.

SW1

SW2

Note

OFF

OFF

Main

 

module (A)

OFF

ON

Dock

 

(B)

ON

OFF

Dock

 

(C)

ON

ON

Dock

 

(D)

2

Dial

 

Switch

 

Setting

Alignment reference 
line at left edge

Picture 2

 

Confirm

 

hole

 

positions

A1

A2

A3

A4

430mm

5

1

0

m

m

3

2

0

m

m

95mm

240mm

Содержание ZCS-KDCA1

Страница 1: ...Quick Start Guide Data Docking Station...

Страница 2: ...www kedacom com 1...

Страница 3: ...2 AC100V 240V 50 60HZ 7 24 250W 10 C 55 C 10 95 RH 4 3 1 1...

Страница 4: ...3 1 A1 A2 A3 A4 8mm 4 400mm SW1 SW2 OFF SW1 SW2 OFF OFF A OFF ON B ON OFF C ON ON D 2 2 A1 A2 A3 A4 430mm 510mm 320mm 95mm 240mm 3...

Страница 5: ...4 2 A1 A2 A3 A4 5 10mm 3 5 10mm 3 4...

Страница 6: ...1 A1 A2 8mm 2 4 A1 A2 510mm 320mm 78mm 95mm 95mm 207mm 5 5...

Страница 7: ...6 6 2 A1 A2 5 10mm 3 A1 A2...

Страница 8: ...1 2 3 4...

Страница 9: ...ality When it is necessary to replace a part please contact your dealer in advance and replace the part with specified model or part with same features We shall not assume any responsibility for probl...

Страница 10: ...er Consumption Working Environment Temperature and Humidity Working Temperature Relative Humidity 250W 10 C 55 C 10 95 RH non condensing 1 Install Hard Disk Picture 1 Install hard disks Hard disk hold...

Страница 11: ...other obstacles There are dial switches and tags at the top right corner on the back of the main module and the docks The tags are indicated below When installing the device please adjust the dial swi...

Страница 12: ...rew bolts external Picture 3 Fix screw bolts Tapping screw bolt 3 Align the left side of the device to the reference lines for installation Place the device downward from the top and lock the hardy ho...

Страница 13: ...A1 and A2 and then strike the expansion screw tubes into the holes 2pcs in total 4 Install Docks A1 A2 510mm 320mm 78mm 95mm 95mm 207mm Picture 5 Con rm hole position Alignment reference line at top e...

Страница 14: ...ew bolts external 3 Align the top and the left sides of the dock to the reference lines for installation and thus the hardy holes at the back of the device will be able to hang on the tapping screw bo...

Страница 15: ...rranty does not apply a to consumable parts such as batteries unless failure has occurred due to a defect in materials or workmanship b to cosmetic damage including but not limited to scratches dents...

Страница 16: ...using new or previously used parts that are equivalent to new in performance and reliability or ii exchange the Kedacom Product for a refund of your purchase price A Kedacom replacement part or produ...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...6841 8188 Fax 86 512 68412699 Suzhou Keda Technology Co Ltd Singapore 627A Aljunied Road 09 07 BizTech Centre Singapore 389842 Tel 65 6842 5700 Fax 65 6842 5900 05 03 800475 V1 20170120 Overseas Hotl...

Отзывы: