High Speed Dome Camera
User Manual
17
Note: The pan range of IPC421-B230-H0 is 0~358
˚. The PTZ holder will stop rotation when reaching its
pan limits. Please strictly follow the Quick Start Guide during installation. The functions of preset position
loading and path patrol won
’t be affected.
4.2.1
Preset Position
Preset position includes information of PT position and lens focal length. It is set by user and can be
loaded, modified or cancelled anytime.
Setting steps:
1)
Go to
Settings > Camera > PTZ > Preset
, adjust PTZ to expected position.
2)
Select
Preset No.
from the drop-down list and input
Preset Name
.
3)
Click
“Set”
to finish preset setting. User can define different preset positions.
Click “
Load
” to load the expected Preset No. and click “
Delete
” to remove the preset ID.
In the preset part of the
Live View
interface, user can also select a preset ID
to load, set or
clear.
Picture 4-5 Preset Position
4.2.2
Guard Tour
Guard Tour means the dome camera can perform preset operations if not receiving any command in a
specific period of time (i.e. the Waiting Time in the setting interface). After stopping PTZ operations for a
certain period of time, user can enable the Guard Tour function.
Pan Mode:
Camera rotates in pan direction from 0° to 360° automatically. The Waiting Time is 1 minute
by default (configurable).
Tilt Mode:
Camera patrols vertically from -15° to 90° automatically within its limits. The Waiting Time is 1
minute by default (configurable).
Load Preset:
After user stops operating on the camera for a certain period of time, the camera will return
to a preset position automatically. The Waiting Time is 3 minutes by default (configurable). Please refer to
the part of preset position for setting steps.
Path Mode:
After user stops operating on the camera for a certain period of time, camera will enable Path
Mode automatically. The Waiting Time is 1 minute by default (configurable). Please refer to the part of
path mode for setting steps.
Frame Mode:
In every key frame interval, camera rotates automatically in pan direction by 90°. The
Waiting Time is 1 minute by default (configurable).