background image

 

Illustration of display screen 

 

                A

Low battery                       

                B

Readings 

                C

Measuring scan                                           

                D

Laser ON 

                E

                                               

 

                F

   

 

                G

Data hold 

Operation Steps 

1.

 

Pull the trigger to start the instrument and measuring. Be sure to hold the trigger more than 0.5 

seconds to have an accurate data. The scan icon flashes while measuring; After the trigger 

released, the data is auto hold and the scan icon disappears. The screen shows hold. Auto shut 

off if there is no action in 7 seconds. 

2.

 

Switch between Fahrenheit and Centigrade be pressing the right key on the panel. Turn on and 

off the backlight using the left key. 

3.

 

Activate and deactivate the laser pointer using the middle key on the panel. 

4.

 

When the battery is low, 

will appear on the screen. 

Operation Instructions 

 

Battery installation

 

Open the battery compartment, insert one 9V battery (6F22/6LR61), close the lid.   

 

Measuring temperature

 

1

Point the product to target objects, hold the trigger to read the data.   

2

The distance and target area: the value of D:S must be considered ( as showed ), the ratio 

should no more than the value of D:S. The field of view must be full of objects. As the 

distance from the object increases, the spot size of measuring area becomes larger.   

 

Содержание KC-180B

Страница 1: ...Infrared Thermometer Model KC 180B Operation Manual Infrared Thermometer ...

Страница 2: ...re measuring without compromising the temperature field It is a good measuring tool for the metallurgy the electric power plant the chemical industry the rubber industry the spinning and weaving the plastic the papermaking and the food processing KC 180B Infrared thermometer is Class II laser product and in compliance with EN60825 1 Safety Instructions Failure to follow the instructions listed bel...

Страница 3: ...rges Please dispose the batteries properly High temperature will cause explosions and do not burn the batteries Strap insulated tape around the battery charges to avoid unsafe contacts with other objects Many countries have regulations regarding battery disposal Please follow the local regulations of battery disposing Tool components A Laser pointer B Infrared sensor C Trigger ON Measuring key D B...

Страница 4: ...ressing the right key on the panel Turn on and off the backlight using the left key 3 Activate and deactivate the laser pointer using the middle key on the panel 4 When the battery is low will appear on the screen Operation Instructions Battery installation Open the battery compartment insert one 9V battery 6F22 6LR61 close the lid Measuring temperature 1 Point the product to target objects hold t...

Страница 5: ...get within the range Show OH The target temperature higher than range Choose target within the range No suitable object and view field Choose proper field of view Temperature differs much Wrong emissivity setting choose proper emissivity value Maintenance 1 Cleaning the lens Abrupt temperature changes will cause vapor please clean after the vapor disappears Blow off loose particles using clean com...

Страница 6: ...n in 7s Power supply One 9V battery 6F22 6LR61 Max power 30mA Operating temperature 0 40 32 104 Operating humidity RH 0 75 non condensing Storage temperature 20 60 4 140 85 w o battery Product dimension 135mm x 170mm x 36mm Product weight About 168g w o battery Warranty The product is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase ...