Keba Kemro K2 Скачать руководство пользователя страница 3

GA1060 Field bus master module 

Contents 

Project Engineering Manual, version: 1.1 / article no.: 1000296 

© KEBA 2006 

 

History 

Modification 

from / to 

Date Modified 

pages 

Description Author 

V1.0 /  

100106 

 

 

meis 

V1.0 / V1.1 

030806 

10, 11 

Changes to chapter "Creation of cfg-file"  

meis 

 

 

 

 

 

 

Содержание Kemro K2

Страница 1: ...Kemro K2 SANMOTION C FM 299 A GA1060 Field bus master module Project Engineering Manual V 1 1...

Страница 2: ...At various points in this manual you will see notes and precautionary warnings regarding possible hazards The meaning of the symbols used is explained below DANGER DANGER indicates an imminently haza...

Страница 3: ...Contents Project Engineering Manual version 1 1 article no 1000296 3 KEBA 2006 History Modification from to Date Modified pages Description Author V1 0 100106 meis V1 0 V1 1 030806 10 11 Changes to ch...

Страница 4: ...Contents SANMOTION C FM 299 A 4 Project Engineering Manual version 1 1 article no 1000296 KEBA 2006...

Страница 5: ...figuration 9 Configuration with the KEMRO Manager 9 Creation of cfg file 10 Setting the K Bus address 11 4 Connections wiring 12 SDC Bus interface 12 General information 12 Connector 12 Cable 12 Cable...

Страница 6: ...Contents SANMOTION C FM 299 A 6 Project Engineering Manual version 1 1 article no 1000296 KEBA 2006...

Страница 7: ...Manual version 1 1 article no 1000296 7 KEBA 2006 1 Brief description The FM 299 A module is a K2 200 field bus master module for the Sanyo Denki drive bus FM 299 A CN1 STATUS CN2 RX TX Front view FM...

Страница 8: ...ed as an open type equipment so that it must be installed in a control cabinet z The safety instructions in the project engineering handbook K2 200 automation system are to be complied with CAUTION Tu...

Страница 9: ...Via Kemro manager through the creation of cfg files with a text editor Two FM 299 A modules can be operated on one CPU Configuration with the KEMRO Manager The Kemro managers can be used to configure...

Страница 10: ...1060B_Bus cycleTime 0 002 traceWord 0 The following information describes the configuration of one of SDC s QSE drive controller Please refer to the relevant drive documentation for a description of t...

Страница 11: ...IO ONBOARD KBUS 0 FM299A 0 optional 0 optional configuration 0 when the module is not available an Error occurs 1 when the module is not avialable a Warning occurs Setting the K Bus address The module...

Страница 12: ...ell The cable shielding must be connected plane with the shield cover of the plug An additional connection of the shield and the ground is not necessary Pin assignment Pin Meaning Pin1 GA1060 Bus Pin2...

Страница 13: ...er side can be routed parallel to one another and parallel to the energy supply lines Bus topology The GA1060 drive bus is a bus system that must be closed on either end with a bus terminating board T...

Страница 14: ...minating board If the FM 299 A is connected at one bus terminating board of a GA1060 drive bus a terminating board must be connected to the free plug This is done by soldering a resistance with 120 in...

Страница 15: ...ion and displays Status LED LED color Function orange System start up green Communication alive no error red After switch on module faulty In cyclical mode Communication error no communication possibl...

Страница 16: ...he status display Max number of modules at one CPU module 2 GA1060 Interface Data transmission rates 10 Mbit s Max cable length 10 m between first and last participant Dimensions Footprint Module heig...

Отзывы: