System overview

With P30 x-series, several charging stations can be interconnected in the
form of a master/slave network. This makes charging with an intelligent load
management possible. In addition, a connection to a higher-level OCPP
backend can take place. The charging station is equipped with different net-
work interfaces for these functions.

Fig. 2-2: Example network setup

1

 ... Local charging network

2

 ... Router/Switch

3

 ... Master charging station (x-series)

4

 ... Slave charging station (c-series)

5

 ... Higher-level network/Internet

6

 ... OCPP backend

Only P30 x-series, can be operated as master charging stations; only P20/
P30 c-series can be operated as slave charging stations.

The following chapters describe which network interfaces P30 x-series (mas-
ter charging station) provides and how to set up a master/slave network.

2.1

Network interfaces

P30 x-series provides the following network interfaces (e.g. for connection to
an OCPP backend, ...):

LAN

WLAN (optional)

WLAN access point (optional)

Mobile communications (optional)

Slave charging stations can only be connected via LAN to P30 x-series
(master charging station).

Содержание KeContact P30

Страница 1: ...KeContact KC P30 x series Charging Station Configuration manual V 4 09 Translation of the original instructions ...

Страница 2: ... due to further technical developments Details presented may be subject to correction All rights reserved KEBA AG Headquarters Gewerbepark Urfahr 4041 Linz Austria 43 732 7090 0 kecontact keba com www keba com emobility For information about our subsidiaries please look at www keba com ...

Страница 3: ... Design of a local charging network master slave 13 3 Configuration 16 3 1 Connection panel 16 3 2 DIP switch settings 16 3 3 Enabling the DHCP server 17 3 4 Configuration in series via USB stick 17 4 Web interface 21 4 1 Main menu 22 4 2 User menu 27 5 Functions 29 5 1 Load management in the local charging network 29 5 2 RFID authorization 30 5 3 OCPP backend 34 5 4 Smart Home Interface 36 5 5 In...

Страница 4: ...re The device variant can be determined by the product designation on the type plate The software version can be read out via the web interface For more information see the operating instructions The pictured devices used in this manual are visual examples The figures and explanations contained in this manual refer to a typical device design The devices used by you may differ in their appearance ...

Страница 5: ...ally hazardous situation which can result in death or seri ous bodily injury if the corresponding precautions are not taken CAUTION means that if the corresponding safety measures are not taken a potentially hazardous situation can occur that may result in slight bodily injury Caution means that damage to property can occur if the corresponding safety mea sures are not taken ESD This symbol remind...

Страница 6: ... hazards Knowledge of current valid safety information the mode of operation of the charging station the displays and operating elements of the charging station basics of network technology basics of IT diagnostic options systematic fault analysis and rectification the setting options on the charging station 1 4 Warranty Only general maintenance work that is expressly permitted by KEBA may be perf...

Страница 7: ...on by the specialist dealer or service partner must be ini tiated 1 5 Notes on this document The manual is part of the product It is to be retained over the entire life cycle of the product and should be forwarded to any subsequent owners or users of the product The instructions contained in this manual must be followed precisely Failure to do so could result in the creation of potential sources o...

Страница 8: ...ion Manuals and additional information are available on our website www keba com emobility downloads Designation Target group Operating instructions End customer Electrician Installation manual Electrician UDP Programmers Guide Programmer FAQ End customer Electrician Service technician ...

Страница 9: ...witch 3 Master charging station x series 4 Slave charging station c series 5 Higher level network Internet 6 OCPP backend Only P30 x series can be operated as master charging stations only P20 P30 c series can be operated as slave charging stations The following chapters describe which network interfaces P30 x series mas ter charging station provides and how to set up a master slave network 2 1 Ne...

Страница 10: ...et1 Anschluss LSA Via the LAN interface P30 x series can also be connected to other charging stations whereby a charging network can be realized Information The Ethernet2 connection X3 RJ45 is for diagnose purposes debugging only and may not be used to connect to a network The Ethernet1 connection X4 LSA and the Ethernet2 connection X3 RJ45 are connected in parallel on the PCB and cannot be used a...

Страница 11: ...onnection to an OCPP backend can be made 1 P30 x series 2 Router 3 Internet 4 OCPP backend The technical data of the WLAN module can be found in the Installation Manual Information Only a charging station that is operated as a single charging station can be connected to the router via WLAN A charging station that is part of a charging network master slave network must always be connected to the ro...

Страница 12: ...hich is en closed with the mounting material The following steps are necessary to perform the configuration via a mobile device 1 Connect a mobile device to the WLAN access point 2 Access the IP address of the WLAN access point in a web browser on the mobile device 3 Perform configuration via the web interface see 4 Web interface 2 1 4 Mobile communications optional Certain device variants have a ...

Страница 13: ...ocal charging network is implemented differently 1 slave charging station Direct connection The slave charging station is connected directly to the master charging station Multiple slave charging stations Connection via router or switch The slave charging stations are connected to the master charging station via a router or switch To enable communication between master and slave charging stations ...

Страница 14: ...his case the master charging station must be configured as a DHCP server The IP address is then assigned to the slave charging station by the master charging station 2 2 3 Connection via router or switch If there are multiple slave charging stations these must be connected to the master charging station via a router or switch The connection of the charg ing station to the router switch is made via...

Страница 15: ...tion 2 2 4 Ports for communication in the charging network For the correct communication in the charging network the ports below must be enabled network internally Information If necessary contact your network administrator to enable the ports Port Protocol Definition Description 49153 TCP Within the network Socket of the charging station 15118 TCP Within the network Link connection between the ch...

Страница 16: ...s the housing cover and the connection panel cover must be removed The description of removing the covers and the connection panel can be found in the Installa tion Manual 3 2 DIP switch settings This DIP switch setting must be made for each master and slave charging station to enable charging station communication Caution Possible damage to the DIP switches The DIP switches are rocker switches an...

Страница 17: ...tion is deactivated in the deliv ery state and can be activated via configuration via USB stick or in the web interface 3 4 Configuration in series via USB stick Several P30 x series can be configured with the same settings For this pur pose the configuration of one P30 x series is saved on a USB stick and then transferred to other P30 x series Preparation The following tools are required for the ...

Страница 18: ...B stick to additional charging stations 3 4 2 Read out configuration In order to be able to transfer the configuration of one P30 x series to addi tional P30 x series the USB stick must be connected to the USB interface in the connection panel of the operationally ready and already configured charging station The charging station automatically transfers the configura tion to the USB stick and disp...

Страница 19: ...gurations that only apply to one charging station must be adapted or deleted in the configuration file All settings are listed in the configuration file The figure below shows a sec tion of a configuration file To the left of the equal sign is the name of the setting To the right of the equal sign is the set value Fig 3 5 Section of a configuration file To adapt and delete the specific configurati...

Страница 20: ...iguration can be adapted manually Each of the listed settings can be adapted by editing the value to the right of the equal sign Example of a possible adaptation of the configuration Initial configuration Adapted configuration AuthorizationEnabled true AuthorizationEnabled false Information Invalid settings will not be applied 3 4 4 Import configuration To load the configuration into another P30 x...

Страница 21: ...h integrated DHCP server The charging station automatically receives an IP address via the DHCP server of the router The IP address is displayed on the charging station display when the charging station is re started The IP address can also be determined via the router Master charging station with local DHCP server The local DHCP server has been activated for the master charging station which auto...

Страница 22: ...directly in the web interface next to the respective configuration entry The actual size of the web interface may differ depending on the device vari ant 4 1 Main menu The main menu is divided into the following areas Status Charging Sessions RFID Cards System Configuration 4 1 1 Status This page is divided into the following sections Overview Here basic information about all charging stations in ...

Страница 23: ...the charging plug is unlocked Network Connection Here information about the network interfaces LAN mobile communica tions WLAN and WLAN Access Point of the master charging station is dis played Backend Information about the OCPP backend such as connection status and ad dress is displayed here 4 1 2 Charging Sessions This page displays details about the last 200 charging sessions The Ex port button...

Страница 24: ...here DSW Settings The DIP switch settings of each charging station in the charging network can be displayed here Factory Data Reset The Reset button resets the configuration of the charging station to the fac tory settings and all stored data charging sessions taught in RFID cards web interface password etc is deleted Signed measurement data export The signed measurement data records can be export...

Страница 25: ... station is operated as a single charging station or as a master charging station in a charging network The number of slaves must be entered for a charging network In addition all attached slave charging stations must be entered with their respective se rial numbers Otherwise the slave charging station will not be recognized by the master charging station in the network The serial number is printe...

Страница 26: ...ilure This setting is disabled by default Chargepoint Parameters The connection type 1 phase or 3 phase of the charging station is selected here For a 1 phase connection the power cable wire that is used can also be selected For a charging network the connection type of the slave charg ing stations can also be selected If a slave charging station loses the connection to the master charging sta tio...

Страница 27: ...area Display Text Here you can make settings for the text that is shown on the display de scribing various processes of the charging station The language of the text can be changed the display duration can be configured and the display text itself can be changed The text display is limited to 20 characters and no umlauts or special char acters can be used The abbreviations Wh and kWh must not be u...

Страница 28: ... technician to access the charging station via an encrypted connection These settings can also be configured on the OCPP backend Log Level For error diagnosis it can be necessary to record the operations of the charging station in detail This can be enabled in this area of the DEBUG mode To ensure that the recorded data quantity is not too large the dura tion for the detailed recording must also b...

Страница 29: ...ions Charging current per charging station set maximum current per phase number of active charging sessions on this phase If insufficient power is available for an additional charging process in the charging network set minimum current is underrun the new charging process will be lined up Every 15 minutes an active charging session is paused in sequence lined up at the back of the line and the nex...

Страница 30: ... cards can be stored It is not possible to teach in the RFID cards directly at a charging station The first 1000 RFID cards are relayed from the OCPP backend to the master charging station where they are stored locally This enables charging ses sions to be authorized even if the connection fails temporarily In case of a connection failure authorization requests depending on the authorization mode ...

Страница 31: ...g is not possible for a connection failure 5 2 2 Displays and signals During RFID authorization the charging station can display different light patterns on the LED bar and emit acoustic signals LED bar Display Description Flashing green every 3 seconds Authorization is done correctly Flashing blue every 3 seconds The charging station is waiting for authorization to enable a charging process Autho...

Страница 32: ...ront of the RFID reader A successful teach in process is confirmed by a rising tone sequence Teaching in a slave RFID card 1 Hold the master RFID card in front of the RFID reader and wait for the rising tone sequence 2 Then hold the slave RFID card to be programmed in front of the RFID reader within 10 seconds and wait for the signal tone 3 Confirm the teach in process by holding up the master RFI...

Страница 33: ...on in the web interface to ON Each authorization request is relayed to the OCPP backend Authorization in the web interface to OFF A charging process can only be started without holding up an RFID card if the predefined token set in the configuration is recognized and ac cepted by the OCPP backend Information For information on the functionality and the required settings of the OCPP backend refer t...

Страница 34: ...facturer or sup plier The following OCPP versions are supported OCPP 1 5 via SOAP OCPP 1 6 via SOAP or JSON Connection to an OCPP backend When connecting to an OCPP backend note the following It is recommended that the master charging station on the network be assigned a static IP address based on the MAC address of the device Since the OCPP backend is usually not in the same network the charg ing...

Страница 35: ...backend can be reached 123 UDP Incoming and outgoing Port for the time server of the charging station Supported messages The following table provides an overview of the supported messages Message OCPP 1 5 OCPP 1 6 Authorize x x BootNotification x x ChangeAvailability x x ChangeConfiguration x x ClearCache x x DataTransfer x x GetConfiguration x x Heartbeat x x MeterValues x x RemoteStartTransactio...

Страница 36: ...f external meters The charging station can read out the measured values from external meters via Modbus TCP This allows an intelligent calculation of the charging cur rent provided to the vehicle and the charging process is optimized The measured values that are read out are included in the charging current spec ification The following graphic shows the schematic structure of the system Fig 5 8 Mo...

Страница 37: ... by the DIP switches to regulate the charging current so that the maximum energy supply never exceeds the am perage of the post meter circuit breaker for configuring the DIP switches see 5 5 3 Settings A master charging station can use this this information to regulate the maxi mum charging current for a charging network such that the maximum current and power defined in the web interface is not e...

Страница 38: ...hether you have a single charging station or a charging network Configuration for a single charging station The post meter circuit breaker is designed for a certain amperage To en sure that the charging current can be calculated the amperage of the post meter circuit breaker must be configured by means of the DIP switches in the charging station connection panel If the charging station cannot find...

Страница 39: ...r Configuration for a charging network For a charging network the maximum permitted charging current per phase and the maximum permitted charging capacity for the entire charging net work can be configured in the web interface under Configuration External TCP Meter If the connection to the external meter gets interrupted you can use the web interface to configure the charging capacity at which cha...

Страница 40: ...o vehicle is plugged in at the charging station Information The software update can take up to an hour The update process is indi cated by a slow orange flashing of the LED bar After the software update the charging station restarts automatically The LED bar will flash blue or green depending on the authorization setting Information The power supply must not be interrupted during the software upda...

Страница 41: ...t be activated in the configuration web interface To perform a software update via a USB stick proceed as follows 1 Download the current software for the charging station keb file 2 Plug the USB stick into a PC 3 Format the USB stick with FAT32 4 Create a new directory on the USB stick with the name UPD 5 Copy the downloaded keb file into the UPD directory 6 Connect the USB stick to the USB interf...

Страница 42: ...tic connection monitoring 37 Settings 38 External meters Connection 37 Supported meters 37 L LAN 10 Load management 29 M Master charging station 13 Mobile communications 12 Modbus TCP 36 N Network interfaces 9 O OCPP backend 34 Ports for communication 34 Supported messages 35 R RFID authorization 30 Acoustic signals 31 Authorization modes 30 Connection failure 31 LED bar 31 OCPP backend 33 RFID ca...

Отзывы: